Description
ControlAir Type 595XP explosion-proof I/P transducer
ControlAir Type 595XP converts a 4 to 20 mA signal into proportional pneumatic pressure for a compatible final control element. Unlike the closed-loop Type 950XP, Type 595XP controls pressure through open-loop conversion. The enclosure is NEMA 4X/IP65 with approvals depending on the selected version.
Key Product Details
- Supplier: ControlAir
- Manufacturer model: Type 595XP
- Store SKU: Type 595XP
- Product type: explosion-proof I/P transducer
- Distinguishing details: 4 to 20 mA input; boosted or low-flow options
- Product category: IP Transducers
Type 595XP operation
The open-loop low-mass mechanism supports operation in vibrating installations. The selected connection determines whether a flow booster is present, so a low-flow model should not be sized from the boosted variant’s capacity.
Type 595XP boosted and low-flow versions
The product family includes a ported transducer with an integral flow booster, a ported low-flow version and a manifold-mount low-flow version. Only the boosted ported configuration carries the published 2.4 SCFM maximum. The low-flow models use considerably less air but depend on a compatible receiving instrument. Maximum supply pressure also changes with the arrangement and selected outlet span. Check the completed code and certified nameplate before assigning a pressure rating or hazardous-area approval to the unit.
Technical specifications
Electrical input: 4–20 mA current loop
Available outlet spans: 3–15, 3–27 or 6–30 psig
Flow configurations: Boosted ported, low-flow ported or manifold options
Flow capacity: Up to 2.4 SCFM for the boosted ported option; low-flow models depend on supply pressure
Maximum supply: 22 psig for a boosted 3–15 psig version, 42 psig for boosted 3–27 or 6–30 psig versions; 150 psig for low-flow versions
Operating medium: clean, dry, oil-free air filtered to 40 microns
Enclosure: NEMA 4X/IP65; site approval depends on completed code
Selection and use
For ControlAir Type 595XP, choose the required air-flow capacity, ported or manifold connection, output calibration, conduit entry and exact applicable hazardous-area marking before ordering.
Route the 4 to 20 mA loop through the selected approved entry, supply regulated instrument air and test the output with the connected valve positioner. Confirm the certified configuration before any hazardous-location installation.
Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.
Lead Time
Product Availability
We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.
Order In and Made to Order Items
Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.
Lead Times and Order Updates
For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.
Delivery Charges
Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.
Availability and Lead Time Enquiries
For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
More Than Components
Experts you can trust. Technologies you can depend on.
Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.
Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.
The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.
Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.
Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.
Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
Applications & Integrations
Applications
ControlAir Type 595XP (SKU Type 595XP) changes a current command to proportional air pressure in an explosion-proof I/P product family. Its compact package is useful in field-mounted valve control where site approval and ambient range match the chosen certified variant. The ordered code determines the actual approval and output range; the family identifier Type 595XP cannot alone prove FM, CSA, ATEX or gas-service suitability. An isolated field valve may require certified I/P conversion at the point where its 4–20 mA loop meets instrument air. The complete hazardous-area marking, ambient conditions and port configuration determine whether the ordered unit fits. Ported and manifold arrangements differ in flow capacity and must be selected for the receiving instrument.
Integrations
Supply instrument air and wire the current signal using the correctly certified electrical entry for the ordered Type 595XP unit. Pipe the proportional outlet and exhaust for the actual air-operated valve or positioner and record the chosen output span. Hazardous-area installation needs confirmation against the precise nameplate and site classification, not the generic family description. Provide upstream filtration, cable glands and any remote tubing separately. Place the supply air filter and pressure measurement as required by the specified valve instrument. The selected I/P converter cannot be treated as an all-in-one air preparation package, and any certification belongs to the exact marked unit.