ControlAir Type 590X manifold I/P transducer
ControlAir Type 590X manifold routes its proportional air output through a compatible mounting face, reducing individual tubing connections to a valve positioner. The separately ported Type 590X remains an alternative where individual threaded connections are required.
Key Product Details
- Supplier: ControlAir
- Manufacturer model: Type 590X manifold mount
- Store SKU: Type 590X-1
- Product type: manifold-mounted I/P transducer
- Distinguishing details: 4 to 20 mA input; low-flow manifold interface
- Product category: IP Transducers
Type 590X manifold mount operation
Open-loop current-to-pressure conversion uses the compact low-mass magnetic mechanism of the Type 590X family. The inlet and outlet meet a common mounting face rather than separate external ported pipework.
Type 590X manifold flow and interface
The manifold version has a low-flow output whose rated capacity depends on the supplied pressure; it is intended for a compatible valve positioner or pilot rather than a large actuator chamber. The supplier identifies a 3/16 inch manifold connection, terminal-block wiring and a replaceable inlet filter. Maintain at least 5 psig supply pressure above the chosen maximum output. The mounting face and its seals must match the receiving assembly, and the low-flow configuration must not inherit the separate ported model’s 2.4 SCFM rating.
Technical specifications
Electrical input: 4–20 mA current loop
Available outlet spans: 3–15, 3–27 or 6–30 psig
Connection: Common mounting face with 3/16 inch manifold interface for pneumatic inlet and outlet
Maximum supply pressure: 150 psig for the manifold family
Output type: Low-flow pneumatic pilot for compatible positioners
Selection and use
For ControlAir Type 590X manifold, specify the mating manifold or positioner face, sealing arrangement, current-input wiring and chosen calibrated output range. Order the matching mounting hardware separately where the assembly requires it.
Provide the clean instrument air feed through the matching interface and check sealing before energising the 4 to 20 mA loop. Commission the installed output across the actuator’s required pressure range.
Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.
Lead Time
Product Availability
We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.
Order In and Made to Order Items
Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.
Lead Times and Order Updates
For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.
Delivery Charges
Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.
Availability and Lead Time Enquiries
For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
More Than Components
Experts you can trust. Technologies you can depend on.
Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.
Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.
The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.
Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.
Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.
Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
Applications & Integrations
Applications
ControlAir Type 590X manifold version (SKU Type 590X-1) uses the Type 590X current-to-pressure conversion function in a manifold-mount arrangement where shared air distribution makes an individually piped unit inconvenient. The distinct mounting interface is the reason to choose this version rather than the directly ported Type 590X. Its selected 4–20 mA electrical input and air-output span must correspond to the plant controller and valve instrument. The shared mounting interface can reduce external pneumatic tubing in a bank of valve-positioning channels. Its output capacity is modest, so the downstream load should be a compatible low-flow pneumatic receiver. The manifold installation is the key distinction from a pipe-mounted transducer.
Integrations
Use a matching manufacturer manifold and seals for the Type 590X mounting face, checking supply and output port alignment before fastening. Connect the specified current loop, deliver clean instrument air through the manifold and lead the pneumatic output to the controlled instrument. The mounting manifold, cable termination and downstream valve are separate unless explicitly included. Test for manifold leakage and check outlet pressure against commanded current. A manifold leak can influence several adjacent channels, so pressure testing must include the mounting seals and adjacent connections. Use the ordered 4–20 mA electrical arrangement with the correct manifold port identification. Keep the electrical and pneumatic interfaces accessible for fault diagnosis.