ControlAir Type 900X closed-loop miniature I/P or E/P transducer
ControlAir Type 900X converts the selected electrical signal into a proportional pneumatic output using internal pressure feedback. Unlike the open-loop Type 590X family, Type 900X employs closed-loop feedback to reduce the effects of mounting position and supply variation.
Key Product Details
- Supplier: ControlAir
- Manufacturer model: Type 900X
- Store SKU: Type 900X
- Product type: closed-loop miniature I/P or E/P transducer
- Distinguishing details: Piezo pilot actuation with pressure-sensor feedback; selected current/voltage input
- Product category: IP Transducers
Type 900X operation
A piezo pilot modulates the relay, while an internal sensor measures outlet pressure so the electronics can correct departures from the command. An integral volume booster supports flow to valves, cylinders and other final elements.
Type 900X electrical and output options
The available voltage-input versions include 0–5, 1–5, 1–9 and 0–10 VDC; these require the matching E/P electronics. The I/P version uses a 4–20 mA current loop. A field-selectable 3–15, 3–27 or 6–30 psig span exists only on the specified option, while zero-based and higher-pressure ranges are separate configurations. An M12 connector does not carry the same agency approvals as every conduit-connected version. Confirm the exact signal and enclosure before ordering.
Technical specifications
Conversion: Selected current input I/P or voltage input E/P
Feedback: Internal pressure sensor; piezo pilot actuator
Available input signals: 4–20 mA or selected voltage input of 0–5, 1–5, 1–9 or 0–10 VDC
Available output spans: discrete choices include 0–5, 3–15 and 2–100 psig; exact span depends on the ordered model
Maximum supply pressure: Up to 130 psig, depending on output range
Voltage-input supply: 7–30 VDC on configured E/P versions
Operating medium: clean, dry, oil-free air filtered to 40 microns
Selection and use
For ControlAir Type 900X, select current-input I/P or voltage-input E/P version, electrical connection, calibrated pressure span and air-supply arrangement by the exact code; the generic family label does not determine them.
Connect the electrical command and a filtered regulated instrument-air feed, then calibrate output across the required pressure range. Check that the actuator flow and the chosen supply meet control response needs.
Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.
Lead Time
Product Availability
We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.
Order In and Made to Order Items
Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.
Lead Times and Order Updates
For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.
Delivery Charges
Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.
Availability and Lead Time Enquiries
For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
More Than Components
Experts you can trust. Technologies you can depend on.
Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.
Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.
The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.
Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.
Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.
Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
Applications & Integrations
Applications
ControlAir Type 900X (SKU Type 900X) converts an ordered electrical current or voltage input into pneumatic pressure within a miniature transducer housing. Its internal pressure feedback and small body suit densely packed pneumatic control panels where a large Type 950XP enclosure or high-output converter is unnecessary. Choose the 900X signal interface and air-output version for the controller and receiving pneumatic device. An OEM panel can use its compact form to move a signal from the controller into a small pneumatic command. The chosen command range and connected receiver should determine the ordered version rather than assuming every 900X has both inputs.
Integrations
Wire the specific Type 900X input and power arrangement to the PLC or process controller, supply filtered air to the inlet and lead output to a suitably sized pneumatic receiver. Protect its exhaust and adjustment points in a tight panel and check loop loading or voltage range against the selected variant. Confirm that actual output pressure follows the command across the chosen span and that actuator demand does not exceed available flow. A high-demand actuator may need an additional, appropriately selected pneumatic booster. Keep electronic command, measured outlet pressure and instrument-air supply separately identified on the cabinet schematic. Commission the pneumatic output with the actual loop interface installed.