Air Engineering Group (AEG) helps oligonucleotide synthesiser manufacturers develop reagent valve manifolds for automated DNA and RNA synthesis. We select Parker valves and design liquid handling assemblies around your reagent list, delivery method, synthesis column connections, and control electronics.

Whether you need additional amidite channels, less shared volume, or more consistent reagent delivery, we help identify practical changes and agree how to test them. Our support covers valve specification, material compatibility, manifold development, prototype testing, and assembled modules for repeat production.

Discuss your synthesis reagent manifold with AEG

Build reagent valve manifolds around the synthesis sequence

Map each reagent from supply bottle to synthesis column

Automated phosphoramidite synthesis uses controlled sequences of amidites, activators, deblock reagents, capping reagents, oxidisers, and wash solvents. The fluidic assembly must deliver these liquids through the connections required by the selected method.

We map each reagent from its supply to the intended column, bypass, or waste connection. This identifies which paths must remain separate, where liquids share passages, and which branches need washing between steps.

Next, we review whether delivery uses pressurised bottles or a pump, together with flow direction and pressure at each valve port. Priming, idle periods, cleaning, and loss of electrical power also form part of the review. These conditions help define the required shutoff and switching functions before we lay out the manifold.

Compare Parker valves for multichannel pneumatic control

Parker identifies cuff inflation and deflation among Series MX applications and compression therapy among C21 pneumatic valve applications. These ranges offer different installation formats and flow options for evaluation within an OEM assembly.

Parker valve familyFormat and functionsWhat AEG assesses
Series MXNominal 10 mm width. Two way and three way configurations, with manifold or barbed tubing connections.Flow at the available pressure differential, channel spacing, electrical connections, and required hit and hold drive.
C21 pneumatic cartridge valves21 mm diameter cartridge. Two way normally closed and three way configurations, with nominal orifices from 1.0 to 4.0 mm.Orifice and pressure limits, machined cavity requirements, external seals, cartridge retention, and service access.

We compare the selected valve’s flow characteristics with the actual pump and chamber pressures. Maximum published flow does not describe the available flow throughout inflation or exhaust, particularly as the pressure difference falls.

These valves switch air paths. Achieving the required chamber pressure also depends on the supply, sensing arrangement, regulation, and controller.

Assess shared supply and exhaust capacity

When several chambers draw air from one supply, we check the combined demand against the pump and shared passages. A channel that fills correctly on its own may respond differently when another valve opens. Pressure measurements at the supply and chamber connections help identify whether the restriction sits in the pump circuit, manifold, or tubing.

The exhaust path needs the same attention. Shared passages, fittings, and silencers must accommodate the intended combination of venting chambers. Excessive exhaust back pressure can extend deflation and affect other connected channels.

We also review how the instrument measures each chamber. A reading at the pump does not, by itself, establish the pressure in an isolated garment section.

Learn more about AEG’s OEM Fluid Technology Division

Separate leakage from interaction between chambers

If a chamber loses pressure during holding, we assess valve seat leakage, external seals, tubing connections, and the garment separately. Isolating sections helps locate the loss before changing components. We then repeat the sequence while neighbouring channels operate to check for unwanted pneumatic transfer.

Garment behaviour also matters. Research has demonstrated that mechanical interaction between adjacent cuff chambers can alter chamber pressure during sequential inflation. A pressure change therefore needs investigation before it is attributed to leakage between manifold passages.

Comparing tests with defined volumes and representative garments helps your team distinguish pneumatic faults from changes caused by chamber movement and loading.

Explore AEG’s OEM Custom Manifold Solutions

Match electrical demand to simultaneous valve operation

Series MX Model 7 requires hit and hold control. Parker specifies a minimum 50 ms actuation stage at rated voltage, followed by reduced holding voltage. Continuous operation at full actuation voltage is not permitted. Parker describes hit and hold as an optional power reduction method for C21 valves.

We review opening current, holding demand, switching frequency, and the maximum number of energised valves. Testing includes supply variation and temperature within the intended enclosure, particularly where multiple channels remain active.

Electrical holding current keeps a valve actuated. Holding pressure within a garment chamber depends on the pneumatic arrangement. We check both requirements against the operating sequence and the selected driver.

Learn more about our iSAR Integrated Fluid Manifold Technology

Reduce tubing complexity while preserving service access

We arrange shared supply and exhaust passages around the chamber connections, looking for opportunities to shorten tubing and remove unnecessary fittings. The layout must also retain access to pressure measurement points, electrical connectors, and replaceable valves.

For Series MX, we review port alignment, gasket contact, fastening, and connector clearance. For C21 cartridges, we check cavity geometry, seal contact surfaces, retention, and removal access against the selected drawing.

Clear channel references and consistent connector orientation help production teams follow the intended routing. We include these details in the assembly drawing so inspection can identify crossed lines, incorrect valve positions, or missing connections.

Explore AEG’s custom manifold development capabilities

Verify pressure profiles with garments and tubing

Before prototyping, we agree limits for pressure variation, filling time, holding drift, pressure after exhaust, channel interaction, electrical demand, and temperature.

Tests use your pump, controller, sensors, and tubing with representative chamber volumes, the longest connections, and simultaneous valve operation. Garment tests include chamber expansion and loading of neighbouring sections. We compare valve commands and pressure traces at agreed points before and after changes under identical conditions.

Checks cover stop commands, power loss, and blocked or disconnected tubing, confirming connected paths and the required pressure release.

Learn more about AEG’s Fluid Control Chassis Assemblies

Experience integrating valves into OEM assemblies

For ScubaTx’s organ preservation and transport system, AEG helped turn an existing fluidic concept into an assembled prototype. The project required proportional valve integration alongside manifold refinement and preparation for manufacture.

Working with ScubaTx, Parker, and RVL, we integrated Parker VSO Low Flow valves and supported PCB integration, prototype testing, and controlled assembly.

This work demonstrates our experience bringing component selection, mechanical design, electronics, and manufacturing requirements together within an OEM development programme.

Read how AEG developed the ScubaTx fluidic assembly

Sequential compression manifold questions

Q1: What does a sequential compression valve manifold do?

It routes air between the supply, individual garment chambers, and exhaust. The valve arrangement supports the instrument’s inflation, holding, and deflation sequence. Pressure sensing and control determine how the assembly achieves the specified chamber pressure profiles.

Q2: Can one three way valve provide inflation, isolated holding, and exhaust?

A conventional two position, three way valve provides two switching states. It does not provide a separate isolated hold state. A circuit requiring all three functions needs additional isolation or another arrangement assessed against the complete sequence.

Q3: Can one pump supply several independently controlled chambers?

Yes, provided the pump, valves, shared passages, and control arrangement support the required operating conditions. We assess combined demand and pressure changes when channels switch, including sequences where one chamber fills while others remain pressurised.

Q4: Can the existing pump and garment connections be retained?

Often, provided their capacity, pressure limits, sealing, and connection arrangement suit the revised design. AEG can assess a new manifold around those interfaces and identify where additional chambers or revised timing require changes elsewhere in the circuit.

Q5: Can AEG supply an assembled compression therapy valve module?

Yes. We can agree a supply scope covering the manifold, selected valves, fittings, and associated components. Controlled drawings, a parts list, and agreed test requirements define the module supplied and the connections your production team completes.

Develop your compression therapy valve assembly for production

Prepare each pneumatic channel for repeatable production

Once the circuit is agreed, we label the air supply, chamber outlets, exhausts, and sensor connections to match the control sequence. Consistent references across the manifold drawing, tubing schedule, and wiring list help teams assemble and check each channel.

We record valve part numbers, manifold revisions, sealing details, driver settings, and test conditions for each prototype build. These records help your engineers compare changes and define the configuration released for production.

Read the Parker Series MX valve guide and C21 pneumatic cartridge valve guide for functions, flow references, mounting details, and electrical requirements. Explore other options in our Parker miniature valves and OEM fluid control solutions.

Resolve chamber filling and exhaust challenges with AEG

AEG’s OEM Fluid Technology Division can help you add independently controlled chambers, investigate pressure drift, or reduce manifold and tubing complexity. We review Parker Series MX and C21 pneumatic valve options alongside your pump, garment connections, sensors, and driver to identify practical improvements to the assembly.

Share your chamber count, volumes, tubing lengths and internal diameters, target pressure profiles, sequence timing, and supply voltage. Include available space and expected build quantities. If you have pressure traces or leakage results, mark the valve commands and affected channels so we can agree what to change and how to verify the improvement before your next build.

Call 01342 826488 or email info@aegroup.uk.com.

Improve chamber inflation and exhaust control with AEG

AEG’s OEM Fluid Technology team can help resolve uneven chamber filling, investigate pressure drift, or simplify your manifold and tubing layout. We review Parker Series MX and C21 pneumatic valve options alongside your pump, garment connections, sensors, and controller to identify practical improvements to the assembly.

Share your chamber count and volumes, tubing lengths and internal diameters, target pressure profiles, sequence timing, and supply voltage. Include available space and expected build quantities. If you have pressure traces or leakage results, mark the valve commands and affected chambers so we can agree what to change and how to verify the improvement before your next build.