EXperts you can trust. Technologies you can depend on.

Experts you can trust. Technologies you can depend on.

Parker Series MX Miniature Pneumatic Solenoid Valves for OEMs

Parker Series MX valve with labelled tubing barbs, valve body, solenoid coil, electrical coil pins, and PCB mounting pins.

Compact gas switching with hit and hold drive for portable medical instruments

Air Engineering Group supplies Parker Series MX miniature pneumatic solenoid valves for OEM gas control assemblies. The range uses a solenoid actuated poppet design with normally closed or normally open two way and three way versions, plus a three way distributor function.

Choose the pressure version, function, seal, voltage, and electrical interface together. The 6 psid and 30 psid versions have different flow, Cv, and power references. Both require hit and hold control, which must be included in the instrument’s electrical and timing design.

The nominal 10 mm body supports tubing or manifold integration in compact gas circuits. Include connections, filters, wiring, mounting, and service access in the device layout, then qualify flow, pressure response, leakage, switching, and temperature within the assembled instrument.

How the Parker Series MX valve operates

Electrical energisation changes the poppet position to open, close, or redirect the gas path. Two way versions control a single connection, while three way versions switch between circuit paths. Select the function around the required energised and de energised states.

Use Parker’s pressure and vacuum schematics for the selected function. Confirm supply, load, exhaust, and vacuum port assignments before assembly. Test the complete operating sequence during power interruption, start up, and changes between circuit states.

Tubing and manifold integration

The Series MX body supports barbed tubing or manifold connections. Parker supplies an EPDM manifold gasket with each valve. Design port alignment, sealing, fastening, and electrical clearance around the selected interface, then verify leakage after mounting.

Two way versions retain three external barbs, with one internally blocked. Follow the function drawing rather than assuming every visible connection carries gas. Include connected volume and restrictions from filters, tubing, fittings, and manifold passages when assessing circuit response.

Parker MX Miniature Solenoid valve OEM applications

Oxygen concentrators

Assess sieve bed switching, equalisation, or oxygen delivery against the required pressure differential, flow, and operating sequence. Confirm material compatibility and cleanliness for the intended gas. Qualify leakage, pressure recovery, and timing with the actual filters, tubing, beds, and connected volumes.

Compression therapy equipment

Define inflation, isolation, and venting requirements for each cuff or chamber. Account for connected volume, tubing resistance, and simultaneous channel operation. Qualify the pressure profile, leakage, power loss behaviour, and enclosure temperature with the intended operating sequence.

Negative pressure wound therapy equipment

Assess the valve within the vacuum control circuit, including connected volume, leakage allowance, venting, and pressure recovery. Define contamination protection and prevent collected liquids reaching a valve intended for gas service. Test performance with the final filters, tubing, and instrument sequence.

Portable patient therapy devices

Compare valve power and switching duty with the battery, driver, and thermal budget. Include simultaneous hit demand where several valves share a supply. Verify the required circuit states, pressure response, and behaviour during supply variation and power interruption within the assembled device.

Parker Series MX Valve Selection Benefits

Flow selection at low pressure differential

The two pressure versions provide different published air flow references. Select using inlet and outlet pressures, required flow, and the complete circuit restrictions. Confirm performance at the actual operating point rather than treating the rated flow as available under every condition.

Reduced holding power

Hit and hold drive reduces the power needed to maintain the energised state after actuation. Include hit interval, hold duration, switching frequency, and number of active valves when assessing energy use. Validate the driver and enclosure temperature during qualification.

Tubing or manifold layouts

Barbed connections provide a route for tubing, while manifold mounting brings switching to shared passages. Compare sealing, connection volume, assembly access, and replacement requirements. Confirm port arrangement and supplied gasket against the selected function.

Compact electrical integration

PCB and upright pin interfaces allow selection around the board or harness layout. Include connector clearance, mechanical retention, strain relief, and service access. The PCB version’s mounting pins and coil pins have different roles and should be identified in the assembly drawing.

Parker MX Valve Technical specifications

Confirm the selected configuration’s operating conditions and current drawing. Use the leakage, cycling, and life references as qualification inputs, then validate timing and service life with the intended gas, electrical drive, and operating duty.

ParameterPublished specification
Valve designSolenoid actuated poppet
FunctionsTwo way NC, two way NO, three way NC, three way NO, or three way distributor
MediaNon reactive gases
Pressure versions6 or 30 psid maximum operating differential
Nominal orifice0.075 inch, approximately 1.91 mm
Actuation voltage options5, 12, or 24 VDC, ±5%
Drive methodHit and hold required
Published air leakageLess than 0.2 sccm
Maximum cycling referenceLess than 20 ms
Published life reference25 million cycles, described as worst case tested
Operating environment5°C to 50°C
Storage temperatureMinus 40°C to 70°C
Body and plungerPPE/PA, polyphenylene ether/polyamide
Armature430 FR stainless steel
Seal optionsFKM or silicone; silicone limited to the 6 psi version
Other wetted materials302/304 stainless steel; EPDM manifold gasket
Recommended filtration40 µm
Published weight8.5 g
Published internal volume0.2043 cm³
Electrical interfaceTwo pin PCB or two pin upright; nominal 7.6 mm coil pin spacing
Pneumatic interfaceTubing barbs or manifold mount
Manifold gasketEPDM, supplied with each valve

Pressure and flow versions

Both versions use Parker’s Model 7 designation, but their flow, Cv, and power references differ. Select the complete pressure version rather than the orifice alone. Confirm the permitted absolute inlet and outlet pressures alongside the differential limit.

Parker publishes a proof pressure of 100 psig, 6.9 bar. This is not the operating differential rating. The pressure and vacuum references do not establish a numerical absolute vacuum limit for every proposed circuit.

VersionNominal orificeMaximum differentialTypical air flow at rated differentialNominal CvHit and hold power
6 psid1.91 mm6 psid / 0.4 bar17.5 slpm0.0621.0 W hit / 0.25 W hold
30 psid1.91 mm30 psid / 2.0 bar48 slpm0.0723.0 W hit / 0.75 W hold

The above component specifications come from Parker’s MX Solenoid Valve datasheet.

Learn more about Parker Miniature Valves and Components

Flow and connected volume

Parker’s typical flow curves use air at 20°C. Use the curve for the selected pressure version and state the gas and reference conditions when specifying flow. Account for both inlet and outlet pressures, particularly where back pressure or suction changes during operation.

Measure circuit performance after adding the intended filters, tubing, fittings, and manifold. Valve flow and switching references do not determine the time required to inflate, vent, pressurise, or evacuate the connected volume.

Wetted materials and gas compatibility

Review the PPE/PA body and plunger, stainless steel components, selected FKM or silicone seal, and EPDM manifold gasket against the intended gas. Silicone is listed only for the 6 psi version. Include tubing, fittings, filters, and any cleaning exposure in the compatibility assessment.

For oxygen or other sensitive gas applications, confirm the materials, cleanliness, handling, and documentation for the configuration. Protect the pneumatic path from liquids, particles, and condensate. Qualify the assembled circuit under representative exposure conditions.

Parker MX Manifold and electrical integration

Liquid connections and mounting

Follow the selected drawing for port positions, face seals, locating features, fasteners, and the mating manifold. Check seal material, compression, port alignment, and fitting loads. Verify leakage and port isolation after assembly, and retain access for inspection and valve replacement.

Allow space for the complete installed assembly. Parker lists an 8.7 mm width for the face seal valve, while threaded subbases add to the installation envelope. Confirm dimensions with the current drawing, including connectors, wiring, tubing, and service clearance.

Pins and mounting

The PCB version has electrical coil pins and separate pins for PCB mounting. The upright pin version accepts a mating connector or optional lead assembly. Confirm the pin layout, connector retention, soldering arrangement, and mechanical loads against the current drawing.

Allow space for the complete installed assembly. Parker lists a 38.1 mm length and 10.1 mm width, with different heights for the barbed and manifold interfaces. Include mounting, connectors, wiring, tubing, and service clearance before releasing board or enclosure drawings.

Hit and hold requirements

Parker specifies a minimum 50 ms hit at rated actuation voltage, followed by reduced holding voltage. Full actuation voltage must not be applied for more than 20 seconds. Series MX is not rated for continuous operation at the full actuation voltage.

The less than 20 ms cycling reference is separate from the minimum 50 ms electrical hit. Include both requirements in instrument timing and validate opening, holding margin, release timing, suppression, and temperature with the actual driver.

Pressure versionActuation voltageMinimum hold voltageTypical hold power at 20°CResistance at 20°C
6 psid5 VDC2.5 VDC0.25 W24.5 Ω
6 psid12 VDC6 VDC0.25 W145 Ω
6 psid24 VDC12 VDC0.25 W567 Ω
30 psid5 VDC2.5 VDC0.75 W8 Ω
30 psid12 VDC6 VDC0.75 W50 Ω
30 psid24 VDC12 VDC0.75 W180 Ω

Parker specifies ±5% for actuation voltage and coil resistance. Assess supply capacity using hit demand and simultaneous valve operation. Assess thermal loading using hold power and duty, then measure enclosure temperature during prototype qualification.

Reduced DC voltage and PWM duty cycle describe different drive methods. The Series MX datasheet provides reduced voltage hit and hold values without a numerical PWM frequency or duty cycle. Obtain guidance and qualify any alternative drive method for the selected valve.

Qualification and production planning

the right configuration for procurement

Qualify flow, leakage, switching, pressure response, and temperature with the intended circuit. Test simultaneous operation and power loss. Define inflation, venting, or vacuum recovery criteria for the device.

Specify the Parker part number, function, pressure version, seal, voltage, and electrical interface. Include gas composition, pressures, flow, temperatures, filtration, connected volume, manifold details, and duty.

Confirm the drawing, porting, gasket, and accessories. The manifold gasket is supplied; mounting screws and the optional lead assembly are separate. Provide quantities, qualification timescales, forecasts, delivery requirements, and documentation. Assess lifecycle costs and review changes with engineering.

Discuss your OEM gas control application

AEG’s OEM Fluid Technology Division can guide component selection and assembly development, considering gas compatibility, pressure differential, flow, valve function, hit and hold drive, manifold sealing, filtration, and maintenance requirements.

Share your schematic, gas composition, inlet and outlet pressures, flow, switching sequence, electrical supply, temperatures, connected volume, and quantities. Include inflation, venting, or vacuum targets so we can assess suitable Series MX configurations and integration options.

Browse the Parker Series MX valve range, or contact Air Engineering Group on 01342 826488 or email info@aegroup.uk.com to discuss your medical, analytical, or life science liquid control application.

Find the right Parker valve for your OEM medical or life science application with guidance from Air Engineering Group. Whether you have a part number, a specification, or a fluid control challenge to solve, we can help you assess suitable options and move your project forward.

From selecting and specifying valves for prototype equipment to procurement and after sales support, AEG works with your engineering and purchasing teams to clarify requirements, address integration challenges, and match valves to your application.

Tell us about your application using the form below. Share the details you have, even if your requirements are still developing, and our team will help you identify the next step.