Description
Product Overview
Parker 099-0340-900 is a Series 99 miniature dispense and gas control valve with 2 way normally closed operation, a 0.030 inch (0.76 mm) orifice, a 1250 psig pressure limit, 24 VDC supply and 1/16 inch A-LOK connections. It combines a 316 stainless steel body with Vespel and silver plated nickel seals. The inert non-isolation construction exposes the internal wetted materials to the medium.
This 24 VDC option keeps the 1250 psig pressure rating, 0.030 inch orifice, Vespel poppet and 1/16 inch A-LOK interfaces of the 12 VDC high pressure build. Its nominal current is 500 mA. It supports normally closed gas dosing or compatible liquid dispensing where a 24 VDC control supply is available.
Alternative Configurations
- Parker 099-0051-900: supply voltage changes from 24 VDC to 12 VDC; nominal current changes from 500 mA to 1000 mA; nominal coil resistance changes from 48 ohms to 12 ohms; published hold power changes from 0.52 W to 2.1 W.
- Parker 099-0080-900: pressure limit changes from 1250 psig to 250 psig; orifice changes from 0.030 inch (0.76 mm) to 0.060 inch (1.52 mm); connection changes from 1/16 inch A-LOK to 1/8 inch A-LOK; seat material changes from Vespel to FKM; drawing reference height changes from 41.7 mm to 42.2 mm; mounting centres changes from 11.10 ±0.25 mm to 11.18 ±0.25 mm.
Parker 099-0340-900 Technical Specifications
- Manufacturer and series: Parker Hannifin, Series 99
- Exact part number: 099-0340-900
- Valve function: 2 Way Normally Closed
- Maximum operating pressure: 1250 psig (approximately 86.2 bar)
- Vacuum capability: Down to 1 × 10⁻⁵ Torr, published liquid datasheet family specification
- Orifice diameter: 0.030 inch (0.76 mm)
- Connections: Two ports, 1/16 inch A-LOK
- Body and seal build: 316 stainless steel; Vespel and silver plated nickel
- Other wetted materials: PTFE coated stainless steel armature; stainless steel springs; silver plated nickel gaskets; Vespel poppet
- Electrical rating: 24 VDC, 12 W, 500 mA nominal, 48 ohms ±5% at 21 °C
- Electrical connection: PTFE insulated flying leads, 12 inch (304.8 mm) minimum length
- Response time: Less than 5 ms, published orifice specification
- Helium leakage: 1 × 10⁻⁸ atm cc/sec, gas datasheet family performance specification
- Operating environment: 4 to 105 °C, continuous duty potted coil
- Proof pressure: 1.5 times rated operating pressure, family specification
- Recommended filtration: 40 µm maximum
- Dimensions: 41.7 mm drawing reference height; 19.1 mm square body; 17.5 mm coil diameter; 41.4 mm shown side fitting span excluding assembled compression nuts and ferrules
- Mounting: Two #4-40 UNC-2B mounting holes with 6.4 mm minimum thread depth and 11.10 ±0.25 mm centres
- Compliance: RoHS compliant, family specification
Electrical Control and Mechanical Integration
Ports 1 and 2 are closed to each other when the coil is de-energised and open to each other when energised. Port 1 is under the seat and port 2 is over the seat.
The coil uses 12 W at its rated 24 VDC supply. After full rated 24 VDC actuation, the published hold setting is 5 VDC at 0.52 W. Validate actuation and holding timing in the assembled circuit. Provide an appropriate driver and support the PTFE insulated leads. Use 1/16 inch outside diameter tubing with the A-LOK compression fittings. Compression nuts and ferrules are supplied. Allow access for fitting assembly and tube insertion beyond the shown fitting span.
The 41.7 mm drawing reference height runs from the body base to the coil endplate. Allow additional space for leads, compression nuts and connected tubing. Two #4-40 UNC-2B mounting holes with 6.4 mm minimum thread depth and 11.10 ±0.25 mm centres. Select all wetted materials for the medium and actual temperature. Check flow requirements, inlet and outlet pressure, port assignment and filtration for the complete circuit.
OEM Fluid Control Support
Air Engineering Group Ltd can supply Parker 099-0340-900 and support its 2 way nc function, 24 VDC control and 1/16 inch A-LOK interface within OEM equipment. Support includes valve selection, fluid circuit and manifold design, prototyping, assembly and functional testing against agreed application requirements.
Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.
Brand
Parker
Parker Hannifin develops precision fluid control valves for OEM equipment that requires compact dimensions, reliable switching and efficient electrical control. Its extensive portfolio includes miniature pneumatic solenoid valves, proportional flow valves, cartridge valves and diaphragm isolation valves for controlling gases and liquids. Available configurations support pressure and vacuum switching, proportional flow control and media isolation, with options for manifold, PCB and tube integration.
Parker valve technologies are used within respiratory equipment, anaesthesia systems, patient monitoring devices, diagnostic instruments, laboratory automation and other medical or life science equipment. AEG helps OEM customers select the appropriate valve function, pressure range, flow capacity, voltage, materials, elastomer and connection method, before integrating the selected components into custom manifolds, pneumatic assemblies or complete fluid control solutions.
Lead Time
Product Availability
We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.
Order In and Made to Order Items
Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.
Lead Times and Order Updates
For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.
Delivery Charges
Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.
Availability and Lead Time Enquiries
For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
More Than Components
Experts you can trust. Technologies you can depend on.
Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.
Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.
The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.
Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.
Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.
Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
Applications & Integrations
Applications and Integration
Parker 099-0340-900 combines 2 way nc operation, 1250 psig maximum pressure, a 0.030 inch orifice, 24 VDC control, 1/16 inch A-LOK connections and Vespel and silver plated nickel. This 24 VDC option keeps the 1250 psig pressure rating, 0.030 inch orifice, Vespel poppet and 1/16 inch A-LOK interfaces of the 12 VDC high pressure build. Its nominal current is 500 mA. It supports normally closed gas dosing or compatible liquid dispensing where a 24 VDC control supply is available.
Parker lists liquid CO2 dispensing, surgical refrigerant dispensing and semiconductor refrigerant dispensing as Series 99 family applications. Gas applications include precision dosing, calibrant gas control for mass spectrometers and gas chromatography. Assess the complete wetted-material build and system requirements for the actual medium.
Circuit and Mechanical Integration
Ports 1 and 2 are closed to each other when the coil is de-energised and open to each other when energised. Port 1 is under the seat and port 2 is over the seat. Use 1/16 inch outside diameter tubing with the A-LOK compression fittings. Compression nuts and ferrules are supplied. Allow access for fitting assembly and tube insertion beyond the shown fitting span. Mount the body using two #4-40 UNC-2B holes with 6.4 mm minimum thread depth and 11.10 ±0.25 mm centres. The 41.7 mm drawing reference height runs from the body base to the coil endplate. Allow additional space for leads, compression nuts and connected tubing.
Provide 24 VDC and capacity for the full 12 W coil input. After full rated 24 VDC actuation, the published hold setting is 5 VDC at 0.52 W. Validate actuation and holding timing in the assembled circuit. Use 40 µm maximum filtration and keep the operating environment within 4 to 105 °C.