Description
Product Overview
Parker 099-0107-900 is a Series 99 miniature dispense and gas control valve with 3 way operation, a 0.116 inch (2.95 mm) orifice, a 100 psig pressure limit, 24 VDC supply and 1/4 inch Female VacuSeal connections. It combines a 316 stainless steel body with FKM and silver plated nickel seals. The inert non-isolation construction exposes the internal wetted materials to the medium.
This 24 VDC build combines three-way routing with the largest standard 0.116 inch orifice and 1/4 inch female VacuSeal connections. It retains the 100 psig rating of the two-way VacuSeal option. The upper fitting gives an 82.3 mm reference height, so vertical access and the side fitting arrangement are relevant when selecting space for a switching assembly.
Alternative Configurations
- Parker 099-0167-900: function changes from 3 Way to 2 Way Normally Closed; published hold voltage changes from 12 VDC to 5 VDC; published hold power changes from 3 W to 0.52 W; drawing reference height changes from 82.3 mm including the upper fitting to 41.7 mm.
- Parker 099-0135-900: orifice changes from 0.116 inch (2.95 mm) to 0.060 inch (1.52 mm); connection changes from 1/4 inch Female VacuSeal to 1/8 inch A-LOK; drawing reference height changes from 82.3 mm including the upper fitting to 54.9 mm including the upper fitting; minimum mounting thread depth changes from 5.1 mm to 6.4 mm; published response threshold changes from less than 6 ms to less than 5 ms.
Parker 099-0107-900 Technical Specifications
- Manufacturer and series: Parker Hannifin, Series 99
- Exact part number: 099-0107-900
- Valve function: 3 Way
- Maximum operating pressure: 100 psig (approximately 6.89 bar)
- Vacuum capability: Down to 1 × 10⁻⁵ Torr, published liquid datasheet family specification
- Orifice diameter: 0.116 inch (2.95 mm)
- Connections: Three ports, 1/4 inch Female VacuSeal
- Body and seal build: 316 stainless steel; FKM and silver plated nickel
- Other wetted materials: PTFE coated stainless steel armature; stainless steel springs; silver plated nickel gaskets; FKM seats
- Electrical rating: 24 VDC, 12 W, 500 mA nominal, 48 ohms ±5% at 21 °C
- Electrical connection: PTFE insulated flying leads, 12 inch (304.8 mm) minimum length
- Response time: Less than 6 ms, published orifice specification
- Helium leakage: 1 × 10⁻⁸ atm cc/sec, gas datasheet family performance specification
- Operating environment: 4 to 105 °C, continuous duty potted coil
- Proof pressure: 1.5 times rated operating pressure, family specification
- Recommended filtration: 40 µm maximum
- Dimensions: 82.3 mm drawing reference height including the upper fitting; 19.1 mm square body; 17.5 mm coil diameter; side fitting extensions of 31.2 mm left and 44.2 mm right from the respective body faces
- Mounting: Two #4-40 UNC-2B mounting holes with 5.1 mm minimum thread depth and 11.18 ±0.25 mm centres
- Compliance: RoHS compliant, family specification
Electrical Control and Mechanical Integration
When de-energised, common port 2 connects to normally open port 3 and port 1 is closed. Energising the coil connects common port 2 to normally closed port 1 and closes port 3.
The coil uses 12 W at its rated 24 VDC supply. After full rated 24 VDC actuation, the published hold setting is 12 VDC at 3 W. Validate actuation and holding timing in the assembled circuit. Provide an appropriate driver and support the PTFE insulated leads. Use matching 1/4 inch VacuSeal components and the specified fitting assembly procedure. The drawing identifies Size 4 fittings with female nuts. Allow clearance for the side fitting nuts, the connected tubing and the upper fitting where present.
The 82.3 mm drawing reference height includes the upper VacuSeal fitting. Side fitting nuts extend below the body datum, so use the complete fitting arrangement and lead routing to establish installation clearance. Two #4-40 UNC-2B mounting holes with 5.1 mm minimum thread depth and 11.18 ±0.25 mm centres. Select all wetted materials for the medium and actual temperature. Check flow requirements, inlet and outlet pressure, port assignment and filtration for the complete circuit.
OEM Fluid Control Support
Air Engineering Group Ltd can supply Parker 099-0107-900 and support its 3 way function, 24 VDC control and 1/4 inch Female VacuSeal interface within OEM equipment. Support includes valve selection, fluid circuit and manifold design, prototyping, assembly and functional testing against agreed application requirements.
Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.
Brand
Parker
Parker Hannifin develops precision fluid control valves for OEM equipment that requires compact dimensions, reliable switching and efficient electrical control. Its extensive portfolio includes miniature pneumatic solenoid valves, proportional flow valves, cartridge valves and diaphragm isolation valves for controlling gases and liquids. Available configurations support pressure and vacuum switching, proportional flow control and media isolation, with options for manifold, PCB and tube integration.
Parker valve technologies are used within respiratory equipment, anaesthesia systems, patient monitoring devices, diagnostic instruments, laboratory automation and other medical or life science equipment. AEG helps OEM customers select the appropriate valve function, pressure range, flow capacity, voltage, materials, elastomer and connection method, before integrating the selected components into custom manifolds, pneumatic assemblies or complete fluid control solutions.
Lead Time
Product Availability
We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.
Order In and Made to Order Items
Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.
Lead Times and Order Updates
For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.
Delivery Charges
Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.
Availability and Lead Time Enquiries
For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
More Than Components
Experts you can trust. Technologies you can depend on.
Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.
Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.
The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.
Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.
Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.
Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
Applications & Integrations
Applications and Integration
Parker 099-0107-900 combines 3 way operation, 100 psig maximum pressure, a 0.116 inch orifice, 24 VDC control, 1/4 inch Female VacuSeal connections and FKM and silver plated nickel. This 24 VDC build combines three-way routing with the largest standard 0.116 inch orifice and 1/4 inch female VacuSeal connections. It retains the 100 psig rating of the two-way VacuSeal option. The upper fitting gives an 82.3 mm reference height, so vertical access and the side fitting arrangement are relevant when selecting space for a switching assembly.
Parker lists liquid CO2 dispensing, surgical refrigerant dispensing and semiconductor refrigerant dispensing as Series 99 family applications. Gas applications include precision dosing, calibrant gas control for mass spectrometers and gas chromatography. Assess the complete wetted-material build and system requirements for the actual medium.
Circuit and Mechanical Integration
When de-energised, common port 2 connects to normally open port 3 and port 1 is closed. Energising the coil connects common port 2 to normally closed port 1 and closes port 3. Use matching 1/4 inch VacuSeal components and the specified fitting assembly procedure. The drawing identifies Size 4 fittings with female nuts. Allow clearance for the side fitting nuts, the connected tubing and the upper fitting where present. Mount the body using two #4-40 UNC-2B holes with 5.1 mm minimum thread depth and 11.18 ±0.25 mm centres. The 82.3 mm drawing reference height includes the upper VacuSeal fitting. Side fitting nuts extend below the body datum, so use the complete fitting arrangement and lead routing to establish installation clearance.
Provide 24 VDC and capacity for the full 12 W coil input. After full rated 24 VDC actuation, the published hold setting is 12 VDC at 3 W. Validate actuation and holding timing in the assembled circuit. Use 40 µm maximum filtration and keep the operating environment within 4 to 105 °C.