Description
John Guest RM070612 Brass Bulkhead Adaptor 6 mm
The John Guest RM070612 brass bulkhead adaptor takes 6 mm outside-diameter tube through an equipment panel. The brass body houses a push-fit collet and nitrile seal for the tube connection.
Key product details
- Supplier: John Guest (RWC)
- Product code: RM070612
- Type: Brass bulkhead adaptor
- Connections: 6 mm
- Product category: Pneumatic Bulkhead Connectors
Selection and use
The John Guest RM070612 passes 6 mm outside-diameter tubing through a wall or partition in a compressed-air line. Match the mounting cut-out and available panel thickness to the brass housing before fitting. Square-cut and fully seat the tube, then inspect the joint before pressurising the line.
Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.
Lead Time
Product Availability
We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.
Order In and Made to Order Items
Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.
Lead Times and Order Updates
For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.
Delivery Charges
Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.
Availability and Lead Time Enquiries
For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
More Than Components
Experts you can trust. Technologies you can depend on.
Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.
Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.
The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.
Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.
Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.
Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
Applications & Integrations
Applications
John Guest RM070612 provides a defined 6 mm tube connection through an equipment panel or enclosure wall. This is useful when a compressed-air or compatible potable-liquid tube needs to pass between internal components and external pipework without leaving an unsupported opening in the panel. Its panel-mounted form provides a connection point separate from the loose tube run. Its tube diameter and brass body distinguish it from visually similar bulkhead connectors in other sizes. It serves as a physical feedthrough, not an isolation or flow-control device. The fixing arrangement keeps the connection at a predictable point on the cabinet. Keeping the transition on the panel can simplify identification of the tubing on each side of the cabinet.
Integrations
In process equipment, dispense cabinets or suitable pneumatic enclosures, position John Guest RM070612 where the 6 mm tube connection must cross the panel. Allow clearance on both faces so tubing can enter its ports without tight bends or side loads. Secure the bulkhead body using the fixing method shown in the John Guest RM070612 drawing; check its actual panel thickness and hole size against the dimensioned drawing before cutting. Keep the two tube runs separate and mark the connection when several adjacent feedthroughs look alike. The resulting panel interface helps keep the equipment accessible for tube changes and routine inspection. A bulkhead connection does not itself establish an enclosure seal.