Description
John Guest PM1210E Bulkhead Connector 10 mm
The John Guest PM1210E bulkhead connector provides a 10 mm push-fit tube connection through an equipment panel. The panel position separates the two sides of the line while keeping the connection accessible.
Key product details
- Supplier: John Guest (RWC)
- Product code: PM1210E
- Type: Bulkhead connector
- Connections: 10 mm
- Product category: Pneumatic Bulkhead Connectors
Selection and use
The John Guest PM1210E holds its tube connection at the panel boundary. Use 10 mm outside-diameter tube on the matching push-fit end. Choose the panel-hole size and wall thickness for this exact body before drilling. The black acetal body has nitrile seals in the push-fit ports.
Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.
Lead Time
Product Availability
We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.
Order In and Made to Order Items
Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.
Lead Times and Order Updates
For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.
Delivery Charges
Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.
Availability and Lead Time Enquiries
For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
More Than Components
Experts you can trust. Technologies you can depend on.
Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.
Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.
The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.
Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.
Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.
Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
Applications & Integrations
Applications
John Guest PM1210E provides a defined 10 mm connection through an equipment panel or enclosure wall. This is useful when a liquid or approved pneumatic tube needs to pass between internal components and external pipework without leaving an unsupported opening in the panel. This fitting uses black acetal with nitrile seals in a range suitable for potable-liquid, mixed-gas dispense or pneumatic circuits where the full assembly is approved. Its actual tube diameter and end form distinguish it from visually similar bulkhead connectors in other sizes. It serves as a physical feedthrough, not an isolation or flow-control device. The fixing arrangement keeps the connection at a predictable point on the cabinet.
Integrations
In process equipment, dispense cabinets or suitable pneumatic enclosures, position John Guest PM1210E where the 10 mm connection must cross the panel. Allow clearance on both faces so tubing can enter its ports without tight bends or side loads. Secure the bulkhead body using the fixing method shown in the John Guest PM1210E drawing; check its actual panel thickness and hole size against the dimensioned drawing before cutting. Keep the two tube runs separate and mark the connection when several adjacent feedthroughs look alike. The resulting panel interface helps keep the equipment accessible for tube changes and routine inspection. A bulkhead connection does not itself establish an enclosure seal. Where access is one-sided, plan the panel position so both connections remain serviceable after installation.