ControlAir Type 550X miniature I/P or E/P transducer
ControlAir Type 550X converts a variable current or voltage command into a proportional pneumatic outlet pressure. The selected connector and optional Type 925 manifold determine how the transducer fits into a compact control panel or grouped air supply.
Key Product Details
- Supplier: ControlAir
- Manufacturer model: Type 550X
- Store SKU: Type 550X
- Product type: miniature I/P or E/P transducer
- Distinguishing details: Miniature body; selectable I/P or E/P signal
- Product category: IP Transducers
Type 550X operation
The compact instrument includes an integral booster and external zero and span adjustment. Pneumatic ports on the front and rear enable installation in dense panel layouts.
Type 550X input and mounting choices
Voltage-input variants include 0–5, 1–5, 1–9 and 0–10 VDC, whereas a current-input version accepts 4–20 mA. These are alternative model choices, not simultaneous inputs. Conduit, terminal-block, DIN 43650 and M12 connections have different wiring and enclosure implications. The optional Type 925 manifold can distribute a common air supply to a bank of corresponding transducers; it must be specified separately. Confirm front and rear port assignment on the selected version before closing the panel.
Technical specifications
Conversion: Current-to-pressure or voltage-to-pressure by selected variant
Available input signals: 4–20 mA or selected 0–5, 1–5, 1–9 or 0–10 VDC variant
Available output spans: 3–15, 3–27, 6–30, 2–60, 3–120 and zero-based versions
Maximum supply pressure: 150 psig for the family
Operating medium: clean, dry, oil-free air filtered to 40 microns
Connections: Conduit, terminal block, DIN 43650 or M12, selected by order code
Selection and use
For ControlAir Type 550X, choose a current-input I/P or voltage-input E/P variant, an output span and electrical connector. The Type 550X model name alone does not fix signal range, mounting form or hazardous-area certification.
Provide filtered instrument air and use a panel, wall, pipe, DIN rail or manifold installation appropriate to the selected body. Verify port direction and calibrate output with the live electrical signal.
Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.
Lead Time
Product Availability
We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.
Order In and Made to Order Items
Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.
Lead Times and Order Updates
For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.
Delivery Charges
Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.
Availability and Lead Time Enquiries
For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
More Than Components
Experts you can trust. Technologies you can depend on.
Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.
Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.
The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.
Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.
Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.
Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
Applications & Integrations
Applications
ControlAir Type 550X (SKU Type 550X) provides electrically commanded pneumatic pressure in a compact housing with an integral flow booster for air-operated control devices. Specify either the appropriate current-input or voltage-input version, together with its required pressure span. The unit can integrate with a Type 925 supply manifold when the corresponding mounting configuration is specified. Specify the Type 925 supply manifold separately when several Type 550X units share an air-preparation assembly. The Type 925 manifold’s common supply and individual shut-off valves are useful when several transducers occupy one panel. A current-input version connects to a process loop, while a voltage-input version needs its corresponding control output. The internal booster supports a useful flow to a suitable pneumatic receiver. Select any hazardous-area option for the installed classification.
Integrations
Match the Type 550X ordered electrical signal, air-pressure span, pneumatic port and mounting option to the controller. Its front and back port arrangements allow a compact cabinet layout, but unused connections must be handled exactly as the manufacturer specifies. Route regulated output and exhaust correctly; the Type 925 manifold, air preparation and remote pressure monitoring are separate unless the selected package includes them. Map every front and back port on the selected enclosure before mounting, especially where a manifold lies behind the instrument. Confirm which of the ordered current or voltage input versions is installed and cap unused pneumatic connections correctly.