ControlAir Type 3500 Brass High Pressure Regulator
The ControlAir Type 3500 provides first-stage reduction of a high-pressure gas supply to a lower pilot or working pressure.
Key Product Details
- Supplier: ControlAir
- Product code: CA_3500
- Manufacturer model: ControlAir Type 3500
- Description: Brass High Pressure Regulator
- Product category: Pneumatic Instrumentation / Air Pressure Regulators / All Pressure Regulators
The Type 3500 provides brass first-stage gas pressure reduction; the Type 3600 is the stainless steel counterpart. Specify the source gas, outlet spring and complete pressure rating before selecting pipework or downstream instruments.
The outlet connections can feed connected instruments if the regulator is sized for their combined demand. Its spring choices are separate adjustment ranges rather than one universal span. Brass construction must suit the selected gas, and the first-stage reduction does not replace downstream overpressure protection. Check each connected branch and any unused outlet plug against the highest foreseeable fault pressure.
The rotatable valve seat block has four sealing surfaces. After isolation and depressurisation, a service technician can present another seat when one becomes worn without replacing the brass regulator body. Confirm the available spare parts against the supplied Type 3500 revision before planning a service interval.
Technical specifications
Function: Brass first-stage pressure regulator for compatible non-corrosive gas.
Maximum inlet: 6,000 psig for correctly configured versions.
Outlet options: 0–30, 0–60, 0–125, 0–150 or 0–225 psig springs.
Connections: 1/4 inch NPT inlet and 1/4 inch NPT outlet connections.
Relief: Non-relieving regulator; downstream protection is a separate system provision.
Selection and use
Specify a complete factory order code against the actual gas, cylinder or process source pressure and required downstream spring. A family maximum inlet rating does not mean each selected trim or installation can accept that condition. Route all outlet ports intentionally and blank unused connections with rated fittings; plan separate protection and isolation for the system.
Choose Type 3500 when the brass material is suitable; select the Type 3600 version for its stainless steel construction and corresponding material requirements.
Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.
Lead Time
Product Availability
We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.
Order In and Made to Order Items
Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.
Lead Times and Order Updates
For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.
Delivery Charges
Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.
Availability and Lead Time Enquiries
For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
More Than Components
Experts you can trust. Technologies you can depend on.
Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.
Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.
The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.
Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.
Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.
Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
Applications & Integrations
Applications
ControlAir Type 3500 (SKU CA_3500) reduces high inlet pressure to the selected, lower instrument-pressure band in a brass-bodied regulator assembly. The Type 3500 family is used in gas pressure-reduction service rather than as a normal plant-air filter; the Type 3600 provides a separate stainless option. Several outlet spring settings are available; the permitted inlet pressure and outlet range must match the installed assembly. In a gas panel, this reducer can form a first-stage pressure reduction ahead of lower-pressure instruments. It should be distinguished from Type 3600 by specified body materials rather than an assumed difference in the regulation principle. The first-stage outlet can then feed an independently rated final regulator.
Integrations
Use the complete Type 3500 part code and site design pressure to select the actual spring, orifice and material compatibility. Connect the 1/4 inch NPT inlet and the selected outlet connections, capping unused ports in accordance with the unit instructions. Provide a filter or dryer upstream if the source demands it, and separately protect the downstream circuit against overpressure. Use a pressure-rated gauge on the outlet side for setting under the real inlet pressure. The installer must identify every connection on the selected multi-port body before installing isolation or an unused-port plug. The correct connection plan should be shown on the instrument line drawing.