Description
ControlAir CA_950XP explosion-proof I/P transducer
ControlAir CA_950XP converts a 4 to 20 mA current input to a directly proportional pneumatic pressure output. It differs from the open-loop Type 595XP through active pressure feedback. The field enclosure is rated NEMA 4X/IP65, and the air inlet and outlet use 1/4 inch NPT connections.
Key Product Details
- Supplier: ControlAir
- Manufacturer model: Type 950XP
- Store SKU: CA_950XP
- Product type: explosion-proof I/P transducer
- Distinguishing details: 4 to 20 mA input; closed-loop pneumatic output
- Product category: IP Transducers
Type 950XP operation
Closed-loop pressure feedback monitors the outlet and corrects deviations. An integral booster supports flow to actuated valves and other pneumatic final elements, while external zero and span settings aid commissioning.
Type 950XP configuration
Choose the pneumatic output span for the receiving actuator and select its completed manufacturer order code. Check the marked hazardous-area approval for classified locations; ATEX requires the K option. Sweet natural gas or methane requires the specified E construction, including its venting arrangement. A tapped exhaust and field-selectable spans are further configuration choices. The field-selectable version has a different published accuracy rating, so do not assume the standard-span value applies to it.
Technical specifications
Input: 4 to 20 mA electrical current
Selectable pneumatic spans: 3 to 15, 3 to 27, 6 to 30 or 0 to 33 psig, according to ordered version
Supply pressure: maximum 100 psig for the first three spans; 70 psig for the 0 to 33 psig version; minimum 5 psig above maximum output
Pneumatic ports: 1/4 inch NPT inlet and outlet
Standard medium: clean, dry, oil-free air filtered to 40 microns
Enclosure: NEMA 4X/IP65; confirm the exact hazardous-area approval and gas-service option on the ordered unit
Selection and use
For ControlAir CA_950XP, choose the specified output range, electrical conduit and exact hazardous-area certification for the finished code. A special option permits sweet natural gas or methane service; the base family designation does not identify that option.
Connect the input to a compatible current loop and feed it with appropriately filtered regulated instrument air. Size the supply and outlet for the actuator flow requirement; confirm the chosen unit’s approval before use in a classified area.
Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.
Lead Time
Product Availability
We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.
Order In and Made to Order Items
Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.
Lead Times and Order Updates
For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.
Delivery Charges
Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.
Availability and Lead Time Enquiries
For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
More Than Components
Experts you can trust. Technologies you can depend on.
Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.
Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.
The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.
Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.
Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.
Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
Applications & Integrations
Applications
ControlAir Type 950XP (SKU CA_950XP) converts a 4–20 mA electronic command to a pneumatic output for a valve positioner or air-operated actuator where an appropriately ordered hazardous-area enclosure is required. Its closed-loop feedback and integral volume booster distinguish it from a basic I/P converter. Select the Type 950XP pressure span, permitted medium and actual FM, CSA or ATEX approval for the installation. In a field valve package, the transducer should be selected against both the control-loop signal and actuator air demand. Do not equate the physical explosion-proof enclosure with a certificate for the exact gas, temperature class and installation. Confirm actuator response at the chosen pressure span.
Integrations
Wire the current loop through the certified cable entry specified for the exact Type 950XP configuration and supply clean instrument air to the pneumatic input. Lead the output to the positioner or actuator and account for the unit’s exhaust path. A natural-gas configuration requires its specifically ordered gas-service components and vent arrangement; ordinary units must not be described as gas compatible. Document loop load, pressure response and enclosure conditions before service. Size the independent air supply for both normal positioning and rapid changes of command. The verified electrical approval and conduit arrangement must suit the site, while the output range must be set for the receiving pneumatic instrument.