ControlAir Type 1000P Electro-Pneumatic Precision Pressure Regulator
The ControlAir Type 1000P uses an electrical setpoint and internal pressure feedback to adjust compressed-air outlet pressure automatically.
Key Product Details
- Supplier: ControlAir
- Product code: CA_1000P
- Manufacturer model: ControlAir Type 1000P
- Description: Electro-Pneumatic Precision Pressure Regulator
- Product category: Pneumatic Instrumentation / Electronic Pressure Regulators
An internal sensor checks the regulated outlet against the selected electrical command. Separate solenoid valves admit air or exhaust it until the measured pressure follows the setpoint.
Selecting a range far above the normal setpoint can reduce useful command resolution. Available flow depends on supply pressure and load, while the monitor signal must match the controller input. The local display can help confirm pressure during commissioning.
ControlAir specifies a response time of approximately 0.8 seconds for the Type 1000P itself. The time taken for a connected vessel or actuator to reach its target pressure will also depend on its volume and the available air supply. Choose the command range and output spring before scaling the controller.
Technical specifications
Control principle: Electrical setpoint with outlet-pressure feedback and inlet/exhaust solenoids.
Outlet ranges: 0–30, 0–60 or 0–120 psig, selected in the completed code.
Input options: 0–5 V, 0–10 V, 1–5 V, 4–20 mA or RS485 Modbus.
Electrical supply and ports: 24 VDC; standard 1/8 inch NPT pneumatic ports.
Maximum inlet: 43, 73 or 131 psig respectively for the 30, 60 or 120 psig range.
Accuracy and response: ±0.1% of full scale; approximately 0.8 seconds response; clean air filtered to 5 microns.
Selection and use
Match the ordered signal, monitor output, pressure range and port standard to the control equipment. Feed the unit clean compressed air filtered to 5 microns and respect the supply-pressure limit for the selected outlet range. A PLC connection or digital interface is an available configuration, subject to the chosen signal configuration.
Compared with the Type 1005P high-flow model, the Type 1000P is intended for smaller downstream pneumatic loads where fine closed-loop adjustment is the priority.
Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.
Lead Time
Product Availability
We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.
Order In and Made to Order Items
Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.
Lead Times and Order Updates
For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.
Delivery Charges
Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.
Availability and Lead Time Enquiries
For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
More Than Components
Experts you can trust. Technologies you can depend on.
Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.
Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.
The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.
Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.
Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.
Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
Applications & Integrations
Applications
ControlAir Type 1000P (SKU CA_1000P) provides closed-loop pneumatic output pressure from a selected electrical command for repeatable automated pressure setpoints. It suits precision test stations and instrument-air controls where measured output feedback matters more than maximum actuator flow. Its selectable signal interfaces include analogue current, analogue voltage and RS485 Modbus, but the supplied configuration must be identified before describing its actual interface. The feedback sensor is useful where a process switches between a low test pressure and a higher production pressure. A chosen RS485 version can be integrated into digital control, but other versions require the corresponding analogue command. Compare pressure at the end device, not just the internal feedback location.
Integrations
Connect the specified electrical command and external power to the exact Type 1000P variant, supply appropriately filtered air and pipe the regulated output to the controlled circuit. The integrated sensor and two solenoid valves adjust output automatically, whereas the PLC, power supply, pneumatic fittings and downstream gauge are separate system components. Match the command and monitor output options to the controller; prove response to both rising and falling setpoints. Signal scaling should agree with the chosen outlet range, including the lower and upper command limits. On a digital variant, configure communications separately from the plant air pipework; the model name alone does not establish its wiring.