Gas Blending Valves for Ventilators and Anaesthesia Machines
Develop your medical gas blending circuit from prototype to production
Air Engineering Group (AEG) helps OEMs develop gas blending circuits for ventilators and anaesthesia machines. We specify Parker proportional valves to meter each gas stream and design the manifold around your total flow and blend targets. We support prototype testing and can supply assembled manifolds for repeat production.
Parker lists its LM-Pro linear motor proportional valve for ventilator gas blending and anaesthesia delivery. We review the gas at each inlet, the lowest flow each valve must control, and the pressures at both valve ports during operation. Those details help us select suitable valves and agree what to check on the bench.
Define the gas blend and total flow separately
In a ventilator with separate air and oxygen valves, we look at how much each channel must deliver across the required combinations of total flow and oxygen concentration. At some settings, one valve may need to hold a small flow while the other supplies most of the mixture. We check that operating point as well as peak demand.
For an anaesthesia machine, we start by identifying where the valve sits in the fresh gas circuit. Depending on the workstation, the mixer may use oxygen with medical air or nitrous oxide. Tell us which gas passes through each valve and where your design specifies the fresh gas flow and composition.
Check the pressure at both ports under flow
The supply pressure gives us a starting point. For each gas channel, we also need the regulated pressure at the valve inlet and the outlet pressure while gas is flowing. We look at how both change as demand rises, taking account of pressure losses through the tubing, filters, and manifold passages. The difference between the inlet and outlet pressures helps determine how much flow the valve can deliver.
We use those conditions to review the flow curves for each candidate. We check whether the valve can hold the smallest flow the blend requires and meet peak demand as pressures vary. This gives your team specific combinations of gas, flow, and pressure to verify in the assembled circuit.
Valve selection, manifold integration, and testing for medical gas blending
Compare Parker LM-Pro valves for your gas circuit
The Parker LM-Pro is a two way, normally closed proportional valve. Its linear motor varies the valve opening as coil current changes. Parker recommends current control for repeatable flow and publishes typical air flow curves for both models with a 12 VDC coil.
| Parker LM-Pro model | Published operating pressure, gauge | Effective orifice |
|---|---|---|
| Model 2 | 0 to 100 psig, approximately 0 to 6.9 bar | 3.07 mm |
| Model 4 | 0 to 50 psig, approximately 0 to 3.45 bar | 3.40 mm |
Parker lists flow up to 540 standard litres per minute (SLPM) across the family. We use the selected model’s curves to assess both ends of your flow range, then check performance with the gas, pressures, and driver your device will use.
Read the Parker LM-Pro valve guide for flow curves and drive requirements. Browse the Parker LM-Pro proportional valve range to compare part numbers, or explore our wider Parker miniature valves and OEM fluid control solutions.
Plan oxygen service and manifold integration together
For passages that carry oxygen, we review the expected concentration, pressure, and cleanliness requirements with your team. Parker’s datasheet states that the LM-Pro is cleaned for oxygen use to ISO 15001:2010. We check the documentation for the selected part number and review the materials, seals, and handling requirements for the rest of the gas path.
As we lay out the manifold, we map each inlet, where the gases combine, and where the sensors need to measure pressure, flow, or oxygen concentration. We also leave access to fittings and seals so your team can check for external leaks and leakage between channels during prototype testing.
Test the blend and total flow on the bench
Before building the prototype, we agree where to measure total flow and oxygen concentration, how closely each must track its target, and how quickly both need to settle after a change in demand. We also agree the leakage limits and include the device team’s specified response to loss of power or a gas supply.
AEG plan the checks with the intended regulators, valve driver, sensors, and downstream load. We record the valve part numbers, manifold revision, driver settings, gas and pressure conditions, and results. That gives your engineering and purchasing teams a common reference when the assembly moves into repeat production.
Gas blending valve selection questions
Q1: What does FiO₂ mean in a ventilator specification?
FiO₂ is the fraction of inspired oxygen. It describes the proportion of oxygen in the gas the patient inhales. When reviewing a prototype, specify where the device will verify that concentration and what tolerance it needs to meet.
Q2: Can the same Parker LM-Pro model meter both air and oxygen?
Parker lists both gases for the LM-Pro range. Check the flow response for each gas and confirm that the exact part number meets the pressure, materials, and cleanliness requirements for its channel.
Q3: What should I allow for if the LM-Pro Model 4 operates at 50 psi?
Parker notes that Model 4 can exhibit a flow shift of up to 5% over the life of the valve when operated at 50 psi. If your design uses that operating condition, include the published shift when planning flow verification over the device’s service life.
Q4: What happens to the LM-Pro when power is removed?
The normally closed LM-Pro returns to its closed position when power is removed. Check shutoff leakage at the relevant pressure and verify the complete device’s response against the requirements set by your design team.
Q5: How should I specify a gas flow in standard litres per minute?
State the reference temperature and pressure behind the SLPM figure, along with the gas being measured. This gives us a common basis for comparing your flow target, the published valve data, and your bench readings.
Discuss your gas blending prototype with AEG
Start with the design information you already have
AEG’s OEM Fluid Technology Division helps you select Parker valves and design manifolds for ventilator gas blending and anaesthesia delivery. We check gas compatibility and review how the valves will work with your regulators, sensors, and control electronics. We work with your engineering and purchasing teams from prototype testing through to production supply and after sales support.
Share a circuit sketch, the gases you need to blend, and the target composition. For each channel, include the flow range, inlet and outlet pressures under flow, and any oxygen service requirements. If you have a flow trace or oxygen concentration reading, tell us how it differed from your target when demand or supply pressure changed.
Specifying valves and manifolds for gas blending
Once your team agrees the design, we help define which components AEG will include in the manifold assembly and which your production team will fit separately. We clarify who supplies items such as electrical connectors, tube fittings, and mounting hardware. We also flag changes that need engineering review before a repeat order, such as a different coil option or a revised port layout.
For flow curves, drive requirements, and mounting details, read the Parker LM-Pro valve guide. Compare part numbers in the Parker LM-Pro proportional valve range, or explore our wider Parker miniature valves and OEM fluid control solutions.
Call 01342 826488 or email info@aegroup.uk.com.
Plan your next gas blending build with AEG
What do you need to resolve before your next ventilator or anaesthesia build? You might need to fit the manifold into an existing enclosure, keep the current valve driver, or understand why the measured blend changed after a design revision.
AEG’s OEM Fluid Technology team can work through that decision with your engineers. We’ll help you identify which Parker valve option to assess, where to revise the manifold, or what to measure in your next bench test.
Show us the part of the circuit you’re working on. A drawing with the area marked, a valve part number, or a short note from the bench is enough to get started.