Parker LM-Pro Linear Motor Proportional Valves for OEMs
Proportional gas control for respiratory equipment and medical instruments
Air Engineering Group supplies Parker LM-Pro linear motor proportional valves for OEM gas control assemblies. The two way normally closed design varies the gas opening through a linear motor, with face seal manifold mounting and an optional inlet filter.
Select the model, coil version, driver, and manifold interface together. Model 2 and Model 4 have different operating pressure limits and effective orifices. Establish the usable control range with the intended gas, inlet and outlet pressures, sensors, and instrument sequence.
Parker recommends current control for repeatable flow performance. Include driver capacity, calibration, hysteresis, thermal behaviour, and feedback in development. Qualify the assembled gas circuit rather than treating electrical command as a fixed flow value.
How the LM-Pro valve operates
The linear motor positions the valve element to vary the gas restriction. Flow depends on the opening, gas properties, and pressure conditions at both ports. The normally closed configuration closes the path when de energised; confirm leakage and the required power loss state within the instrument.
Parker describes a linear flow control range spanning 70% of the current rating. Use the selected model’s curves to establish the opening threshold and useful command range. Include increasing and decreasing commands when calibrating the assembled circuit.
Proportional control within the instrument
Define whether the device controls gas flow, pressure, or a delivery profile. Select the sensor range, response, resolution, and placement alongside the valve and driver. Qualify the feedback loop with the final regulation, tubing, manifold, and downstream load.
Account for supply pressure variation, back pressure, gas changes, and temperature. Measure steady performance and transitions, including command ramps, start up, power interruption, and recovery. Establish acceptance criteria at the measurement or delivery point under representative conditions.
Parker LM-Pro Linear Motor Proportional Valve OEM applications
Ventilator gas blending and delivery
Assess the valve within the gas delivery circuit, including inlet regulation, outlet pressure, flow measurement, and the required waveform. For gas blending, qualify each gas path and the resulting mixture under representative supply and load conditions. Include low flow behaviour, transitions, calibration, and power interruption.
Anaesthesia gas delivery
Confirm compatibility, cleanliness, leakage, and documentation for the intended gases. Define the required flow range and control response at the instrument. Qualify calibration, hysteresis, and pressure variation with the final manifold, sensors, tubing, and delivery sequence.
Insufflation equipment
Evaluate the valve alongside the pressure regulator, flow measurement, and downstream restrictions. Define delivery demand, pressure limits, and behaviour during changing load or supply conditions. Qualify the assembled control circuit, including response, leakage, power loss, and recovery.
Pressure and flow control assemblies
Match the model and driver to the required gas control range and pressure conditions. Include sensor accuracy, circuit volume, filtering, and command resolution. Test steady setpoints, ramps, disturbances, and thermal stabilisation with the intended gas and assembled instrument.
Parker LM-Pro Valve Selection Benefits
Proportional gas adjustment
The linear motor provides a controllable restriction for variable gas delivery. Select the usable range from the model’s pressure and current curves, then calibrate the actual circuit. Include opening threshold, command direction, gas properties, and back pressure in acceptance testing.
Current control options
The valve accepts current or voltage control, with current control recommended by Parker for repeatable flow. Select the driver around the coil, command range, supply margin, and feedback arrangement. Validate the electrical path, including wiring losses and temperature effects.
Face seal manifold integration
The manifold interface places gas switching at the mating passages, with an integrated FKM seal and optional inlet filter. Assess port positions, sealing surfaces, fastening, and service access. Include manifold restrictions and connected volume when evaluating response.
Model selection for pressure and flow
Model 2 and Model 4 provide different operating pressure limits and effective orifices. Compare the selected model’s flow curves, leakage, drive current, and life references together. Include calibration and maintenance requirements when assessing the assembly over its service life.
Parker LM-Pro Valve Technical specifications
Confirm the selected part’s specification and installation envelope against the current drawing. Use the response and life references as qualification inputs, then validate instrument timing and service life with the actual gas, drive, pressure conditions, and operating duty.
| Parameter | Published specification |
|---|---|
| Valve function | Two way normally closed proportional |
| Actuation | Linear motor |
| Published gas media | Air, oxygen, nitrous oxide, carbon dioxide, heliox, and other medical gases |
| Range flow reference | Up to 540 slpm; selected model and pressure conditions apply |
| Coil voltage options | 5, 12, or 24 VDC |
| Control | Current or voltage; current control recommended |
| Power reference | 2.0 W nominal; 3.0 W maximum |
| Typical hysteresis | 10% of full scale current |
| Maximum hysteresis | 15% of full scale current |
| Response reference | Less than 10 ms typical at 20°C |
| Published life reference | 100 million cycles; 0.95 reliability factor at 95% confidence |
| Internal leakage limit | 1 sccm of air under Parker’s specified test conditions |
| External leakage limit | 1 sccm of air under Parker’s specified test conditions |
| Published vacuum range | 0 to 27 inHg, 686 mmHg vacuum |
| Operating environment | 0°C to 55°C |
| Storage temperature | Minus 40°C to 70°C |
| Published basic dimensions | 39.9 mm length, 18.3 mm width, 36.5 mm height |
| Published weight | 36.6 g |
| Wetted materials | Aluminium, FKM, fluorosilicone, and stainless steel |
| Pneumatic interface | Face seal manifold mount with integrated FKM seal |
| Optional inlet filter | 400 µm |
| Electrical termination | JST SM02B-PASS-TB latching receptacle |
Model pressure and orifice comparison
The pressure limits are published as gauge pressure. Confirm inlet, outlet, and differential pressure requirements for the proposed circuit. Proof pressure does not establish a permitted operating pressure. The vacuum figure is a vacuum reading rather than an absolute pressure value.
The effective orifice figures follow Parker’s performance specification. Confirm the full ordering code and current drawing for the selected assembly.
| Model | Published operating pressure | Effective orifice | Published proof pressure |
|---|---|---|---|
| Model 2 | 0 to 100 psig / 6.9 bar | 0.121 inch / 3.07 mm | 150 psig |
| Model 4 | 0 to 50 psig / 3.45 bar | 0.134 inch / 3.40 mm | 110 psig |
The above component specifications come from Parker’s LM-Pro Valve datasheet.
Learn more about Parker Miniature Valves and Components
Flow curves and calibration
Parker’s typical air flow curves for Models 2 and 4 use a 12 VDC coil. Select the relevant curve and confirm gas and reference conditions when specifying flow.
Measure increasing and decreasing command curves with the intended circuit. Hysteresis is a percentage of full scale current, not flow accuracy. Test flow error, repeatability, settling, and stability within the instrument.
Model 4 may exhibit up to 5% flow shift over its life at 50 psi. Include calibration allowance, verification, and maintenance intervals in qualification.
Wetted materials and gas preparation
Assess aluminium, FKM, fluorosilicone, stainless steel, and connected circuit materials against the intended gas and cleaning exposure. Confirm the cleaning, handling, and documentation required for oxygen or other sensitive gas applications. Protect the manifold and valve from liquids, particles, and condensate.
The optional integrated inlet filter is listed at 400 µm. Specify the instrument’s filtration and cleanliness requirements separately, including any upstream treatment. Qualify pressure drop, contamination protection, and filter access with the assembled circuit under representative conditions.
Parker LM-Pro Electrical and Mechanical integration
Coil selection and current drive
Use the selected coil’s current reference when designing the driver and command limits. Confirm supply margin, current regulation, wiring losses, and thermal loading. The values in this table describe maximum flow control current and should be assessed with the model specification.
Parker’s example control circuit uses a separate input signal and valve driver. Define the command interface at the driver, then qualify the resulting coil current and gas response. Include sensor feedback where measured flow or pressure must be maintained as circuit conditions change.
| Coil voltage option | Nominal coil resistance at 20°C | Published control current at maximum flow |
|---|---|---|
| 5 VDC | 6 Ω | 555 mA |
| 12 VDC | 24 Ω | 280 mA |
| 24 VDC | 148 Ω | 115 mA |
PWM and connector requirements
For PWM control, Parker specifies a frequency of 5 kHz or greater, with the optimum frequency depending on the application. Validate current ripple, command resolution, acoustic behaviour, temperature, and control stability with the actual driver and circuit.
The valve is polarity sensitive. Follow the cover markings and current drawing when wiring the latching receptacle. Confirm the mating connector, cable retention, strain relief, and service access before releasing the electrical assembly.
Manifold mounting
The inlet and outlet face seal ports sit beneath the aluminium body. Follow the drawing for port alignment, sealing surfaces, fasteners, and the filtered inlet. Verify leakage after assembly and include manifold passages when measuring pressure drop and response.
Allow space for the installed assembly, including connectors, wiring, filters, and service access. Confirm the supplied FKM manifold seal and required mounting hardware. Check fastener engagement and sealing compression against the current assembly drawing.
Qualification and production planning
the right configuration for procurement
Qualify flow, leakage, hysteresis, repeatability, response, and temperature. Test command ramps, pressure disturbances, power loss, and calibration recovery. Include Model 4’s flow shift allowance where applicable.
Specify the part number, model, coil voltage, filter, manifold, and driver. Provide gas composition, inlet and outlet pressures, flow, accuracy, temperatures, filtration, sensors, and duty.
The FKM seal is supplied; leads, screws, and the evaluation manifold are separate. Confirm the code, drawing, and hardware. Provide quantities, qualification timescales, forecasts, delivery requirements, and documentation. Assess lifecycle costs and review changes with engineering.
Discuss your OEM proportional gas control application
AEG’s OEM Fluid Technology Division can guide component selection and assembly development, considering gas compatibility, pressure differential, flow range, current drive, sensor integration, manifold sealing, filtration, and maintenance requirements.
Share your schematic, gas composition, inlet and outlet pressures, flow targets, control accuracy, electrical supply, temperatures, sensors, and quantities. Include command profiles and calibration requirements so we can assess suitable LM-Pro configurations and integration options.
Browse the Parker LM-Pro proportional valve range, or contact Air Engineering Group on 01342 826488 or email info@aegroup.uk.com to discuss your medical, analytical, or life science liquid control application.
Find the right Parker valve for your OEM medical or life science application with guidance from Air Engineering Group. Whether you have a part number, a specification, or a fluid control challenge to solve, we can help you assess suitable options and move your project forward.
From selecting and specifying valves for prototype equipment to procurement and after sales support, AEG works with your engineering and purchasing teams to clarify requirements, address integration challenges, and match valves to your application.
Tell us about your application using the form below. Share the details you have, even if your requirements are still developing, and our team will help you identify the next step.