EXperts you can trust. Technologies you can depend on.

Experts you can trust. Technologies you can depend on.

Parker C15-312EP20FF-000 3-Way NC 12 VDC EPDM 2.0 mm Cartridge Valve

Function: 3-way NC; de-energised output-to-exhaust path
Performance: 14.5 psi (1 bar) maximum pressure; 29 SLPM maximum airflow; Cv 0.076
Orifice: 0.080 in (2.0 mm); 10 µm filtration
Coil: 12 VDC; 1.7 W; 85 Ω; 80 mm leads
Integration: EPDM seals; 15 x 29 mm face-seal cartridge; O-rings installed

This product is supplied to order, so pricing may vary. Contact us for up-to-date pricing and availability.

Not all items are held in stock as some are made to order or sourced on request. In-stock items usually arrive within 1–2 days, and we’ll confirm lead times by email once your order is processed.

Need help with this product or looking for an alternative? Talk to an expert today by emailing info@aegroup.uk.com or calling 01342 826488.

Description

Product Overview

The Parker C15-312EP20FF-000 is the largest orifice 3-way EPDM valve in the C15 family. Its 2.0 mm passage, 12 VDC coil and cartridge format provide normally closed supply and exhaust control for compact, lower pressure pneumatic assemblies.

How C15-312EP20FF-000 Differs

C15-324EP20FF-000 matches the 2.0 mm EPDM pneumatic specification at 24 VDC, with a 1.6 W, 361 ohm winding instead of the 1.7 W, 85 ohm coil. C15-312FK20FF-000 preserves the 12 VDC, 2.0 mm configuration but uses FKM seals. The adjacent C15-312EP15FF-000 reduces nominal Cv from 0.076 to 0.048, while increasing maximum pressure from 14.5 to 50.8 psi and maximum airflow from 29 to 41 SLPM.

Technical Specifications

  • 3-way normally closed supply and vent function
  • 2.0 mm orifice, nominal Cv 0.076
  • Maximum pressure 14.5 psi (1 bar)
  • Maximum airflow 29 SLPM
  • 12 VDC ±5%, 1.7 W, 85 ohm ±5% at 20°C
  • 80 mm flying leads, 24 AWG and stripped at the ends
  • EPDM internal and external seals, with O-rings installed
  • 10 ms maximum cycling response
  • 461 µL internal volume

Application and Integration

When the coil is off, output port 2 is open to exhaust port 3 and supply port 1 is closed. Applying power opens supply port 1 to output port 2 and shuts the exhaust. The cartridge is 15 mm in diameter, 29 mm long and 22 g, supporting dense manifold layouts in portable respiratory, analytical and dispense equipment.

OEM Pneumatic Control Support

Use 10 µm filtration, secure the valve at the mid-body indent and do not exceed 100 N insertion force. The specified operating range is 0°C to 50°C, and the 3-way mechanism is rated for 200 million cycles at a 0.90 reliability factor with 95% confidence. Optional hit and hold control can be validated to reduce power after a minimum 100 ms actuation pulse.

For C15 selection and manifold integration support, contact the AEG sales team on 01342 826488 or at info@aegroup.uk.com.

Brand

Parker

Parker Hannifin develops precision fluid control valves for OEM equipment that requires compact dimensions, reliable switching and efficient electrical control. Its extensive portfolio includes miniature pneumatic solenoid valves, proportional flow valves, cartridge valves and diaphragm isolation valves for controlling gases and liquids. Available configurations support pressure and vacuum switching, proportional flow control and media isolation, with options for manifold, PCB and tube integration.
Parker valve technologies are used within respiratory equipment, anaesthesia systems, patient monitoring devices, diagnostic instruments, laboratory automation and other medical or life science equipment. AEG helps OEM customers select the appropriate valve function, pressure range, flow capacity, voltage, materials, elastomer and connection method, before integrating the selected components into custom manifolds, pneumatic assemblies or complete fluid control solutions.

Technical Information

Technical Specifications

Series and ISO
C15 C15 3-Way

Voltage:
12 VDC (±5%)

Valve Operation Type:
Electronic

Valve Actuation:
Solenoid-actuated cartridge valve

Valve Function:
3-Way Normally Closed

Operating Pressure:
1 bar configuration

Orifice Size:
0.080 inch (2.0 mm)

Primary Material:
300 and 400 series stainless steel

Filter Grade in micron:
10 µm

Manufacturer:
Parker

Max Supply Pressure:
14.5 psi (1 bar)

Power Supply:
1.7 W

Response:
10 ms maximum cycling response

Temperature Range:
0 to 50 °C

Vacuum Range:
Vacuum-compatible porting

Operating Media:
Gases and liquids, subject to media compatibility

ROHS Compliant:
YES
Material:
EPDM
Temperature Max (Celsius):
50 °C
Temperature Minimum (Celsius) EU:
0 °C
Temperature Minimum (Fahrenheit):
50 °C

 

Air Engineering Group makes every effort to provide the most current product details directly from our manufacturers. However, because manufacturer specifications change frequently, we recommend verifying critical dimensions or performance metrics with our team prior to purchase.

 

Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.

Lead Time

Product Availability

We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.


Order In and Made to Order Items

Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.


Lead Times and Order Updates

For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.


Delivery Charges

Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.


Availability and Lead Time Enquiries

For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.

More Than Components

Experts you can trust. Technologies you can depend on.

 

Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.

 

Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.

 

The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.

 

Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.

 

Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.

 

Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.

Applications & Integrations

Large Passage for Lower Pressure Circuits

Parker C15-312EP20FF-000 addresses 12 VDC systems where the largest C15 3-way orifice is more important than the pressure capacity available from the smaller passages. It can serve low pressure respiratory gas routing, compact analyser manifolds, portable environmental instruments and pneumatic air over liquid dispense control.

The 2.0 mm orifice provides the highest nominal Cv in the C15 3-way family at 0.076. Maximum pressure is 14.5 psi (1 bar). Maximum airflow is 29 SLPM. These separate ratings define a different selection point from the smaller orifices: a larger internal passage with lower maximum pressure and lower listed maximum airflow than the 1.0 and 1.5 mm versions. Its 12 VDC coil is rated at 1.7 W with 85 ohm resistance.

Exhaust Routing

De-energised, output port 2 connects to exhaust port 3 while supply port 1 is blocked. Energised, supply port 1 connects to output port 2 and the exhaust closes. The M3 top vent allows the exhaust path to be managed within the equipment layout. Use the EPDM option only after assessing the specified gas circuit, cleaning process and surrounding materials for EPDM.

Explore Our Related Parker OEM Capabilities:

Parker Precision Miniature Valve Solutions
Learn how AEG supplies and integrates Parker miniature solenoid and proportional valves.
Follow the process from application review and concept development through to prototyping, manufacture and assembly.
OEM Pneumatic and Fluid Control Solutions
Explore our capabilities in component integration, custom manifolds and complete OEM assemblies.
Medical Device OEM Solutions
Discover our support for medical device fluid control systems, subassemblies and repeat production.

Associated Products

Components Integrated into OEM Solutions

Our capabilities extend beyond individual component supply. We integrate pneumatic and fluid control products into custom manifolds, control assemblies and complete OEM solutions developed around the specific technical, operational and production requirements of each machine, device or system.

AEG can assist from initial concept and component selection through to prototyping, assembly and testing. By combining proven products with practical design expertise, we help OEMs reduce connections, simplify installation, improve repeatability and prepare reliable solutions for ongoing production.