Description
Product Overview
The Parker C15-312EP15FF-000 combines a 1.5 mm flow passage with 3-way normally closed control, EPDM sealing and a 12 VDC coil. It is designed for manifold installation where a compact valve must alternately feed and vent a pneumatic output.
How C15-312EP15FF-000 Differs
C15-324EP15FF-000 offers the same 1.5 mm EPDM pneumatic ratings for a 24 VDC supply, using 1.6 W and 361 ohm rather than 1.7 W and 85 ohm. C15-312FK15FF-000 retains the 12 VDC, 1.5 mm configuration with FKM seals. The adjacent C15-312EP20FF-000 increases nominal Cv from 0.048 to 0.076, but maximum pressure falls from 50.8 to 14.5 psi and maximum airflow falls from 41 to 29 SLPM.
Technical Specifications
- 3-way normally closed cartridge valve
- 1.5 mm orifice, nominal Cv 0.048
- Maximum pressure 50.8 psi (3.5 bar)
- Maximum airflow 41 SLPM
- 12 VDC ±5%, 1.7 W and 85 ohm ±5% at 20°C
- 80 mm stripped flying leads in 24 AWG wire
- EPDM internal and external seals, with O-rings installed
- 10 ms maximum cycling response and 10 µm filtration recommendation
- Operating temperature from 0°C to 50°C
Application and Integration
Without electrical power, port 2 discharges through exhaust port 3 and supply port 1 remains blocked. With the coil powered, supply port 1 feeds port 2 while port 3 is closed. The 15 mm diameter by 29 mm long face seal cartridge weighs 22 g and contains 461 µL internal volume, helping designers package the pneumatic function close to the controlled load.
OEM Pneumatic Control Support
The cartridge should be secured at its central indent, with insertion force kept within 100 N. Parker rates the 3-way design for 200 million cycles at a 0.90 reliability factor and 95% confidence. An optional hit and hold drive can apply rated voltage for at least 100 ms before moving to a validated reduced hold condition.
For C15 selection and manifold integration support, contact the AEG sales team on 01342 826488 or at info@aegroup.uk.com.
Brand
Parker
Parker Hannifin develops precision fluid control valves for OEM equipment that requires compact dimensions, reliable switching and efficient electrical control. Its extensive portfolio includes miniature pneumatic solenoid valves, proportional flow valves, cartridge valves and diaphragm isolation valves for controlling gases and liquids. Available configurations support pressure and vacuum switching, proportional flow control and media isolation, with options for manifold, PCB and tube integration.
Parker valve technologies are used within respiratory equipment, anaesthesia systems, patient monitoring devices, diagnostic instruments, laboratory automation and other medical or life science equipment. AEG helps OEM customers select the appropriate valve function, pressure range, flow capacity, voltage, materials, elastomer and connection method, before integrating the selected components into custom manifolds, pneumatic assemblies or complete fluid control solutions.
Lead Time
Product Availability
We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.
Order In and Made to Order Items
Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.
Lead Times and Order Updates
For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.
Delivery Charges
Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.
Availability and Lead Time Enquiries
For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
More Than Components
Experts you can trust. Technologies you can depend on.
Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.
Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.
The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.
Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.
Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.
Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
Applications & Integrations
Medium Pressure Manifold Control
Parker C15-312EP15FF-000 is intended for 12 VDC pneumatic assemblies that benefit from a larger flow passage while retaining more pressure capacity than the 2.0 mm C15 model. Application examples include respiratory equipment fill and release functions, negative pressure wound therapy manifolds, analytical chambers and the pneumatic side of air over liquid dispense equipment.
Its 1.5 mm orifice gives a nominal Cv of 0.048. Maximum pressure is 50.8 psi (3.5 bar). Maximum airflow is 41 SLPM. The larger Cv distinguishes it from the 0.5 and 1.0 mm variants, while its pressure and airflow ratings both exceed those of the 2.0 mm 3-way valve. The 12 VDC coil requires 1.7 W and has 85 ohm resistance.
Controlled Fill and Exhaust
In the de-energised state, output port 2 is open to exhaust port 3 and supply port 1 is closed. Energising the valve feeds output port 2 from supply port 1 and blocks the exhaust. Designers can route the M3 top vent to a controlled exhaust location. Choose the EPDM configuration after confirming that EPDM suits the gas circuit, cleaning agents and adjacent materials.