The Parker C15-212EP10FF-000 combines a 1.0 mm orifice with 12 VDC operation, 2-way normally closed switching and EPDM seals. It is designed for manifold mounted pneumatic equipment needing greater airflow than the 0.5 mm version while retaining a high maximum pressure rating.
How C15-212EP10FF-000 Differs
- Voltage alternative: C15-224EP10FF-000 has the same 1.0 mm, Cv 0.032, 116 psi and 55 SLPM pneumatic specification, but changes to a 24 VDC, 1.6 W, 361 ohm coil from this model’s 12 VDC, 1.7 W, 85 ohm coil.
- Seal alternative: C15-212FK10FF-000 substitutes FKM seals for EPDM without changing the stated pneumatic or electrical ratings, allowing elastomer choice to follow the gas compatibility assessment.
- Orifice alternative: C15-212EP05FF-000 uses a 0.5 mm orifice and increases maximum pressure to 145 psi, but lowers maximum airflow to 18 SLPM and Cv to 0.01.
Technical Specifications
- Function: 2-way normally closed, with ports 1 and 2 isolated de-energised and connected energised
- Orifice and flow coefficient: 1.0 mm, Cv 0.032
- Maximum pressure: 116 psi (8 bar)
- Maximum airflow: 55 SLPM
- Coil: 12 VDC, 1.7 W, 85 ohm resistance at 20°C
- Electrical connection: 80 mm, 24 AWG flying leads, stripped at end
- Materials: Series 300 and 400 stainless steel body with EPDM seals
- Performance: 10 ms maximum cycling response, 10 µm recommended filtration and 500 million cycle nominal life
- Envelope: 15 mm diameter, 29 mm length, 22 g weight and 391 µL internal volume
Application and Integration
This model provides a practical pressure and airflow combination for 12 VDC pneumatic subassemblies, including portable respiratory equipment and air over liquid dispensing systems. Its cartridge face seal permits a compact manifold cavity. The valve isolates ports 1 and 2 when de-energised and connects them when energised. O-rings are installed before shipment, and EPDM suitability should be checked for the intended gas.
OEM Pneumatic Control Support
For assistance selecting between the 1.0 mm C15 valve and adjacent orifice options, contact the AEG sales team on 01342 826488 or email info@aegroup.uk.com.
Brand
Parker
Parker Hannifin develops precision fluid control valves for OEM equipment that requires compact dimensions, reliable switching and efficient electrical control. Its extensive portfolio includes miniature pneumatic solenoid valves, proportional flow valves, cartridge valves and diaphragm isolation valves for controlling gases and liquids. Available configurations support pressure and vacuum switching, proportional flow control and media isolation, with options for manifold, PCB and tube integration.
Parker valve technologies are used within respiratory equipment, anaesthesia systems, patient monitoring devices, diagnostic instruments, laboratory automation and other medical or life science equipment. AEG helps OEM customers select the appropriate valve function, pressure range, flow capacity, voltage, materials, elastomer and connection method, before integrating the selected components into custom manifolds, pneumatic assemblies or complete fluid control solutions.
Lead Time
Product Availability
We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.
Order In and Made to Order Items
Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.
Lead Times and Order Updates
For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.
Delivery Charges
Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.
Availability and Lead Time Enquiries
For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
More Than Components
Experts you can trust. Technologies you can depend on.
Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.
Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.
The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.
Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.
Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.
Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
Applications & Integrations
Application and Integration
Parker C15-212EP10FF-000 provides 2-way normally closed switching for 12 VDC pneumatic modules that need a useful balance of pressure capability and airflow. It can be evaluated for portable or transport ventilator assemblies, analytical gas instruments and air over liquid dispense equipment.
- The 1.0 mm orifice and Cv 0.032 deliver more airflow than the 0.5 mm model without accepting the lower pressure ceilings of the 1.5 and 2.0 mm choices.
- Maximum pressure is 116 psi (8 bar). Maximum airflow is 55 SLPM, specified as a separate performance rating.
- The 12 VDC coil is rated at 1.7 W with 85 ohm resistance, making it electrically distinct from the 24 VDC equivalent.
- EPDM internal and external seals should be selected only after compatibility review for the intended gas circuit.
Integration Decisions
A 15 mm cartridge body and 391 µL internal volume help reduce manifold space and pneumatic volume. The face seal interface, installed O-rings and 80 mm flying leads support direct mechanical and electrical integration. Select this version when 55 SLPM maximum airflow and the higher 116 psi maximum pressure rating are both preferable to the different trade-offs offered by adjacent C15 orifices.