Description
Product Overview
Parker 991-003063-025 is configured for 3-way normally open control on the lightweight V2 Model 20 platform. Its model code is Type 4, with a 12 VDC, 0.5 W coil and two solder tabs. It is rated to 6 PSI (0.41 bar) through a 0.050 in (1.27 mm) orifice, nominal Cv 0.030.
Port 3 is supply, port 2 is the load and port 1 is exhaust. De-energised, port 3 supplies port 2; energised, port 3 closes and port 2 exhausts through port 1. Within the V2 model matrix, Model 20 is the lowest-pressure large-orifice model, combining a 0.050 in path with 0.5 W power.
How 991-003063-025 Differs
Three nearby V2 variants show the configuration changes most relevant to selection.
- Closest electrical option: Parker 991-003063-026 changes electrical termination from two solder tabs to four PC pins.
- Voltage or interface alternative: Parker 991-003063-011 changes coil voltage from 12 VDC to 5 VDC and electrical termination from two solder tabs to quick-connect spade.
- Function or mounting alternative: Parker 991-003063-020 changes function from 3-way normally open to 2-way normally closed, Parker model-code type from 4 to 1 and electrical termination from two solder tabs to 18 in wire leads.
Technical Specifications
- Valve: Parker Hannifin 991-003063-025, V2 15 mm direct-acting poppet, Type 4, 3-Way Normally Open
- Performance: 6 psig (0.41 bar), up to 7 SLPM, 0.050 in (1.27 mm), Cv 0.030; vacuum to 27 in Hg (686 mm Hg)
- Coil and termination: 12 VDC, 0.5 W; PCB-mount coil interface with two solder tabs
- Pneumatic connections: 1/8 in (3.18 mm) moulded barbs; 1/8 in (3.18 mm) topseat barb
- Media and wetted materials: compatible non-reactive gases; PBT, 36000 H02 brass, FKM, 430 FR stainless steel and 302 stainless steel
- Dynamic performance: less than 30 ms cycling; less than 0.2 sccm air leak; 25 million-cycle rating
- Temperature: 0 to 70 °C operating; -40 to 70 °C storage
- Size, mass and volume: 50.3 mm L x 15.88 mm W maximum x 17.0 mm H; 34.3 g; 0.016 cm³ internal volume
- Filtration and compliance: 40 micron filtration recommended; RoHS compliant
Application and Integration
This configuration supports default gas delivery without continuous coil power, followed by controlled exhaust, including portable-device gas delivery, analyser purge control and normally open flow paths.
The moulded body barbs accept compatible I.D. tubing and avoid a separate manifold. Confirm tube retention, bend radius and clearance around the port axes. The solder-tab interface supports a direct board connection. Set the PCB spacing from the Parker interface drawing and keep soldering heat and assembly load away from the plastic body. The 12 VDC coil integrates with common instrument control rails; size the output stage and switching protection for the stated coil power. Keep supply pressure within 6 PSI, use 40 micron filtration and operate between 0 and 70 °C.
OEM Pneumatic Control Support
AEG can supply Parker 991-003063-025 and support selection, prototyping, assembly and functional testing for its 6 PSI Model 20 flow path, 3-way normally open porting, 12 VDC drive, two solder tabs and barbed body.
For technical support, contact the AEG sales team on 01342 826488 or email info@aegroup.uk.com.
Brand
Parker
Parker Hannifin develops precision fluid control valves for OEM equipment that requires compact dimensions, reliable switching and efficient electrical control. Its extensive portfolio includes miniature pneumatic solenoid valves, proportional flow valves, cartridge valves and diaphragm isolation valves for controlling gases and liquids. Available configurations support pressure and vacuum switching, proportional flow control and media isolation, with options for manifold, PCB and tube integration.
Parker valve technologies are used within respiratory equipment, anaesthesia systems, patient monitoring devices, diagnostic instruments, laboratory automation and other medical or life science equipment. AEG helps OEM customers select the appropriate valve function, pressure range, flow capacity, voltage, materials, elastomer and connection method, before integrating the selected components into custom manifolds, pneumatic assemblies or complete fluid control solutions.
Lead Time
Product Availability
We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.
Order In and Made to Order Items
Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.
Lead Times and Order Updates
For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.
Delivery Charges
Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.
Availability and Lead Time Enquiries
For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
More Than Components
Experts you can trust. Technologies you can depend on.
Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.
Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.
The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.
Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.
Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.
Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
Applications & Integrations
Applications for 991-003063-025
Parker 991-003063-025 applies Model 20 performance to 3-way normally open control with a 12 VDC coil. The 0.050 in (1.27 mm) orifice, nominal Cv 0.030 and maximum flow of 7 SLPM support portable-device gas delivery, analyser purge control and normally open flow paths with compatible non-reactive gases.
Flow Behaviour
Port 3 is supply, port 2 is the load and port 1 is exhaust. De-energised, port 3 supplies port 2; energised, port 3 closes and port 2 exhausts through port 1.
Typical V2 Applications
V2 valves are used for oxygen-conserver circuits, flow control, shut-off and portable medical-device pneumatics. This SKU’s 3-way normally open state supports default gas delivery without continuous coil power, followed by controlled exhaust.
Integration Checks
The moulded body barbs accept compatible I.D. tubing and avoid a separate manifold. Confirm tube retention, bend radius and clearance around the port axes. The solder-tab interface supports a direct board connection. Set the PCB spacing from the Parker interface drawing and keep soldering heat and assembly load away from the plastic body. The 12 VDC coil integrates with common instrument control rails; size the output stage and switching protection for the stated coil power. Verify the 6 PSI limit, 27 in Hg vacuum capability, 40 micron filtration and 0 to 70 °C operating range.
Selection Notes
Compared with Parker 991-003074-026, this SKU differs by electrical termination from two solder tabs to four PC pins and body connection from barbed body to manifold body. Parker 991-003063-028 provides another nearby choice and changes electrical termination from two solder tabs to 18 in wire leads. Review each changed field against the required port logic, driver and installation layout.