Parker 911-000005-001 SRS Model 13 3-Way NC Miniature Pneumatic Solenoid Valve 20 PSI 0.030 in 5 VDC Front Pins

Function: 3-way normally closed, load vents while supply is blocked when de-energised
Performance: 20 PSI (1.37 bar), 0.030 in (0.76 mm), Cv 0.017
Electrical: 5 VDC, 0.5 W, 0.025 in front square pins
Mounting: 10 mm manifold, gasket supplied
Media and materials: non-reactive gas, PBT, stainless steel and FKM

This product is supplied to order, so pricing may vary. Contact us for up-to-date pricing and availability.

Not all items are held in stock as some are made to order or sourced on request. In-stock items usually arrive within 1–2 days, and we’ll confirm lead times by email once your order is processed.

Need help with this product or looking for an alternative? Talk to an expert today by emailing info@aegroup.uk.com or calling 01342 826488.

Description

Product Overview

Parker 911-000005-001 is an SRS Model 13 10 mm manifold-mounted miniature pneumatic solenoid valve with 3-way normally closed operation. It is rated to 20 PSI (1.37 bar) with a 0.030 in (0.76 mm) orifice, nominal Cv 0.017 and flow up to 9 SLPM. The 5 VDC, 0.5 W coil uses front pins.

For pressure service, port 1 is supply, port 2 is the load and port 3 is exhaust. De-energised, port 2 vents to port 3 while port 1 is blocked; energised, port 1 supplies port 2 while port 3 is blocked. Within the SRS model matrix, Model 13 is the low-power 0.030 in option, with the longest SRS cycle requirement at up to 200 million cycles.

How 911-000005-001 Differs

These nearby configurations isolate the main changes in voltage, electrical termination, pneumatic function and performance model.

  • Voltage alternative: Parker 911-000005-010 keeps Model 13, 3-way normally closed operation and front pins, but changes the coil from 5 VDC to 12 VDC.
  • Electrical-interface alternative: Parker 911-000005-002 keeps Model 13, 3-way normally closed operation and 5 VDC, but changes front pins to manifold pins.
  • Function alternative: Parker 911-000005-004 keeps Model 13, 5 VDC and front pins, but changes from 3-way normally closed to 3-way normally open operation.
  • Performance alternative: Parker 911-000006-001 keeps the same function, voltage and electrical interface, but changes Model 13 (20 PSI, 0.030 in, Cv 0.017, 9 SLPM, 0.5 W, 200 million cycles, 27 in Hg vacuum) to Model 14 (50 PSI, 0.030 in, Cv 0.017, 18 SLPM, 1 W, 25 million cycles, 27 in Hg vacuum).

Technical Specifications

  • Manufacturer and part: Parker Hannifin, 911-000005-001
  • Series and valve type: SRS, 3-port direct-acting poppet valve
  • Function: 3-Way Normally Closed
  • Pressure and flow: up to 20 PSI (1.37 bar) and 9 SLPM
  • Vacuum capability: up to 27 in Hg (686 mm Hg)
  • Orifice and Cv: 0.030 in (0.76 mm), nominal Cv 0.017
  • Coil: 5 VDC ±10%, 0.5 W
  • Electrical termination: Two 0.025 in (0.64 mm) square tin-plated beryllium copper pins at the front interface
  • Pneumatic mounting: 10 mm manifold mount with gasket supplied
  • Media and wetted materials: compatible non-reactive gases; glass-reinforced PBT, 430 FR stainless steel, 300 series stainless steel and FKM
  • Response and leak rate: less than 30 ms cycling; less than 0.016 sccm of air
  • Cycle requirement: up to 200 million cycles
  • Burst pressure: 200 psig (13.7 bar)
  • Temperature: 0 to 50 °C operating, -40 to 70 °C storage
  • Basic envelope and mass: 1.50 x 0.39 x 0.61 in (38.1 x 10.0 x 15.5 mm), approximately 0.23 oz (6.5 g)
  • Internal volume and filtration: 0.0016 in³ (0.027 cm³), 40 micron filtration recommended
  • Compliance: RoHS compliant

Application and Integration

The combination in 911-000005-001 supports default supply isolation, controlled gas admission and load venting when coil power is removed at pressures up to 20 PSI. Typical SRS uses include sensor-zeroing isolation, patient-monitor pressure control, analyser sample isolation and portable-device gas shut-off. These are system applications for compatible non-reactive gases and do not replace the equipment designer’s media and device-level assessment.

The front pins place the electrical contact at the exposed end of the valve. Provide supported PCB or connector geometry, allow front clearance and avoid transferring assembly load into the pins. The 5 VDC coil suits compact electronic controls; size the driver and protection for the stated coil power and switching duty. Install the supplied gasket on a clean manifold face, use 40 micron filtration and keep the ambient temperature between 0 and 50 °C.

OEM Pneumatic Control Support

AEG can supply Parker 911-000005-001 as an individual SRS valve or support its integration into an OEM pneumatic assembly. Selection support can cover the 20 PSI Model 13 flow path, 3-way normally closed porting, 5 VDC drive, front pins, manifold design, prototyping, assembly and functional testing.

For technical support, contact the AEG sales team on 01342 826488 or email info@aegroup.uk.com.

Brand

Parker

Parker Hannifin develops precision fluid control valves for OEM equipment that requires compact dimensions, reliable switching and efficient electrical control. Its extensive portfolio includes miniature pneumatic solenoid valves, proportional flow valves, cartridge valves and diaphragm isolation valves for controlling gases and liquids. Available configurations support pressure and vacuum switching, proportional flow control and media isolation, with options for manifold, PCB and tube integration.
Parker valve technologies are used within respiratory equipment, anaesthesia systems, patient monitoring devices, diagnostic instruments, laboratory automation and other medical or life science equipment. AEG helps OEM customers select the appropriate valve function, pressure range, flow capacity, voltage, materials, elastomer and connection method, before integrating the selected components into custom manifolds, pneumatic assemblies or complete fluid control solutions.

Technical Information

Technical Specifications

Series and ISO
SRS Model 13

Voltage:
5 VDC ±10%

Valve Operation Type:
Electronic

Valve Actuation:
Solenoid-actuated direct-acting poppet valve

Valve Function:
3-Way Normally Closed

Operating Pressure:
20 PSI model

Orifice Size:
0.030 in (0.76 mm)

Primary Material:
Glass-reinforced PBT

Filter Grade in micron:
40 micron recommended

Manufacturer:
Parker

Max Supply Pressure:
0 to 20 PSI (0 to 1.37 bar)

Response:
Less than 30 ms cycling

Temperature Range:
0 to 50 °C

Vacuum Range:
Up to 27 in Hg (686 mm Hg)

Operating Media:
Compatible non-reactive gases

ROHS Compliant:
YES
Material:
FKM
Temperature Max (Celsius):
50 °C
Temperature Minimum (Celsius) EU:
0 °C
Temperature Minimum (Fahrenheit):
50 °C

 

Air Engineering Group makes every effort to provide the most current product details directly from our manufacturers. However, because manufacturer specifications change frequently, we recommend verifying critical dimensions or performance metrics with our team prior to purchase.

 

Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.

Lead Time

Product Availability

We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.


Order In and Made to Order Items

Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.


Lead Times and Order Updates

For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.


Delivery Charges

Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.


Availability and Lead Time Enquiries

For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.

More Than Components

Experts you can trust. Technologies you can depend on.

 

Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.

 

Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.

 

The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.

 

Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.

 

Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.

 

Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.

Applications & Integrations

Applications for 911-000005-001

Parker 911-000005-001 combines 3-way normally closed operation, a 20 PSI rating and front pins for compact non-reactive gas circuits. The 0.030 in (0.76 mm) orifice, nominal Cv 0.017 and flow up to 9 SLPM suit sensor-zeroing isolation, patient-monitor pressure control, analyser sample isolation and portable-device gas shut-off. Operate only with compatible non-reactive gases.

Flow Behaviour

In pressure service, the de-energised valve connects load port 2 to exhaust port 3 and isolates supply port 1. Energising the coil opens port 1 to port 2 and closes port 3. For vacuum use, place vacuum at port 3, the load at port 2 and atmosphere at port 1; the unpowered valve applies vacuum and the powered valve vents the load.

Typical SRS Applications

The SRS platform is used in medical and analytical gas control, blood-pressure monitoring, sensor zeroing, patient-monitor pneumatic circuits and portable medical devices. Model 13 adds 20 PSI capacity and a 0.030 in flow path for default supply isolation, controlled gas admission and load venting when coil power is removed.

Integration Checks

Verify the 20 PSI pressure limit and 27 in Hg vacuum limit, install the manifold gasket on a clean sealing face and use 40 micron filtration between 0 and 50 °C. The front pins place the electrical contact at the exposed end of the valve. Provide supported PCB or connector geometry, allow front clearance and avoid transferring assembly load into the pins. The 5 VDC coil suits compact electronic controls; size the driver and protection for the stated coil power and switching duty.

Selection Notes

For a paired-model comparison, Parker 911-000006-001 uses Model 14 (50 PSI, 0.030 in, Cv 0.017, 18 SLPM, 1 W, 25 million cycles, 27 in Hg vacuum). For an electrical-interface comparison, Parker 911-000005-002 changes front pins to manifold pins. Review every stated change before selecting the driver and manifold layout.

Explore Our Related Parker OEM Capabilities:

Parker Precision Miniature Valve Solutions
Learn how AEG supplies and integrates Parker miniature solenoid and proportional valves.
Follow the process from application review and concept development through to prototyping, manufacture and assembly.
OEM Pneumatic and Fluid Control Solutions
Explore our capabilities in component integration, custom manifolds and complete OEM assemblies.
Medical Device OEM Solutions
Discover our support for medical device fluid control systems, subassemblies and repeat production.

Associated Products

Read more

Read more

Read more

Read more

Components Integrated into OEM Solutions

Our capabilities extend beyond individual component supply. We integrate pneumatic and fluid control products into custom manifolds, control assemblies and complete OEM solutions developed around the specific technical, operational and production requirements of each machine, device or system.

AEG can assist from initial concept and component selection through to prototyping, assembly and testing. By combining proven products with practical design expertise, we help OEMs reduce connections, simplify installation, improve repeatability and prepare reliable solutions for ongoing production.