Description
Product Overview
Parker 018-0074-900 is a Series 18 miniature PTFE manifold valve with 4 independently controlled two-way normally closed stations and 12 VDC operation. It connects 4 liquid branches to one common port through an isolated PTFE wetted path. Maximum operating pressure is 20 psig, approximately 1.38 bar.
Four independently controlled liquid branches suit multi-solvent selection and gradient mixing in a 12 VDC instrument. This build has a 57.1 µL outlet path and a published four-station weight of 352 g. The 5 VDC, 0.44 W solenoid hold setting offers reduced input after actuation while retaining all four channels.
Alternative Configurations
- Parker 018-0048-900: supply voltage changes from 12 VDC to 24 VDC; published coil input changes from 2.5 W to 4.2 W; published nominal current changes from 211 mA to 173 mA; published nominal coil resistance changes from 57 ohms to 139 ohms; published hold voltage changes from 5 VDC to 8 VDC; published hold power changes from 0.44 W to 0.46 W.
- Parker 018-0083-900: station count changes from 4 to 3; total fluid ports changes from 5 to 4; published configuration weight changes from 352 g to 289 g; outlet path volume changes from 57.1 µL to 42.4 µL.
Parker 018-0074-900 Technical Specifications
- Manufacturer and series: Parker Hannifin, Series 18
- Exact part number: 018-0074-900
- Valve configuration: 4 stations; two-way normally closed at each station
- Fluid ports: 4 branch ports and one common port, 5 fluid ports in total
- Connections: 1/4-28 UNF-2B female flat-bottom threaded ports
- Operating pressure: Vacuum to 20 psig (approximately 1.38 bar)
- Orifice: 0.062 inch (1.57 mm), published ordering value
- Proof pressure: 1.5 times rated operating pressure
- Wetted materials: PTFE body, seals and poppet diaphragms; all wetted parts PTFE
- Electrical supply: 12 VDC
- Published coil rating: 2.5 W; 211 mA nominal; 57 ohms ±5% at 21 °C
- Electrical connection: 12 inch (304.8 mm) 26 AWG PTFE insulated lead wires
- Response time: Less than 12 ms, published family specification
- Leak performance: Bubble tight, published family specification
- Operating environment: 4 to 66 °C; 100% continuous duty
- Internal volume: Valve: 12.6 µL; inlet path: 25.2 µL; outlet path: 57.1 µL
- Weight: 12.4 oz (352 g), published 4-station configuration figure
- Life rating: 10 million cycles, application dependent
- Recommended filtration: 10 µm maximum
- Reference geometry: Drawing references: 104.4 mm span across opposed coils; 38.1 mm square central body; 31.8 mm body thickness; 20.6 mm coil diameter
- Mounting: 2 mounting through holes, 4.1 mm diameter, in the central manifold body
- Compliance: RoHS compliant, family statement
Fluid and Electrical Integration
Each of the 4 stations is independently controlled and normally closed. Its branch port is isolated from the common port when de-energised and opens to the common port when energised. Use the branch ports as inlets for flow mixing, or the common port as the inlet for selection and stream splitting.
For optional hit and hold drive, apply the full rated 12 VDC for initial actuation, then reduce to 5 VDC at 0.44 W, the published solenoid hold setting. The drive diagram illustrates 25 ms at rated voltage before the hold phase. Validate timing in the assembled circuit. Provide separate control for the 4 coils and size the supply for the number of stations energised together.
2 mounting through holes, 4.1 mm diameter, in the central manifold body. Use matching 1/4-28 UNF-2B fittings for the flat-bottom liquid ports. Allow space beyond the drawing references for fittings, connected tubing and lead routing. Select all valve and fitting materials for the liquid, concentration and temperature. Keep the manifold within its 20 psig rating, including when installed on the solvent side of an HPLC pump.
OEM Fluid Control Support
Air Engineering Group Ltd can supply Parker 018-0074-900 and support its 4-station layout and 12 VDC control within OEM liquid systems. Support includes valve selection, circuit and manifold design, prototyping, assembly and functional testing against agreed application requirements.
Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.
Brand
Parker
Parker Hannifin develops precision fluid control valves for OEM equipment that requires compact dimensions, reliable switching and efficient electrical control. Its extensive portfolio includes miniature pneumatic solenoid valves, proportional flow valves, cartridge valves and diaphragm isolation valves for controlling gases and liquids. Available configurations support pressure and vacuum switching, proportional flow control and media isolation, with options for manifold, PCB and tube integration.
Parker valve technologies are used within respiratory equipment, anaesthesia systems, patient monitoring devices, diagnostic instruments, laboratory automation and other medical or life science equipment. AEG helps OEM customers select the appropriate valve function, pressure range, flow capacity, voltage, materials, elastomer and connection method, before integrating the selected components into custom manifolds, pneumatic assemblies or complete fluid control solutions.
Lead Time
Product Availability
We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.
Order In and Made to Order Items
Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.
Lead Times and Order Updates
For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.
Delivery Charges
Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.
Availability and Lead Time Enquiries
For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
More Than Components
Experts you can trust. Technologies you can depend on.
Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.
Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.
The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.
Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.
Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.
Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
Applications & Integrations
Applications and Integration
Parker 018-0074-900 provides 4 normally closed liquid channels with 12 VDC control, 5 threaded fluid ports and a 20 psig pressure limit. Four independently controlled liquid branches suit multi-solvent selection and gradient mixing in a 12 VDC instrument. This build has a 57.1 µL outlet path and a published four-station weight of 352 g. The 5 VDC, 0.44 W solenoid hold setting offers reduced input after actuation while retaining all four channels.
Parker lists liquid chromatography gradient generation, liquid selection and mixing as family applications. Its symmetrical manifold design gives each fluid channel the same path length and timing characteristics.
Circuit and Mechanical Integration
Each of the 4 stations is independently controlled and normally closed. Its branch port is isolated from the common port when de-energised and opens to the common port when energised. Use the branch ports as inlets for flow mixing, or the common port as the inlet for selection and stream splitting.
The published volume breakdown is valve: 12.6 µl; inlet path: 25.2 µl; outlet path: 57.1 µl. Use these separate path values when reviewing delay volume. For optional hit and hold drive, apply the full rated 12 VDC for initial actuation, then reduce to 5 VDC at 0.44 W, the published solenoid hold setting. The drive diagram illustrates 25 ms at rated voltage before the hold phase. Validate timing in the assembled circuit. Provide separate control for the 4 coils and size the supply for the number of stations energised together.
Mount through the 2 holes of 4.1 mm diameter and allow access to all 5 liquid ports. Use matching 1/4-28 UNF-2B fittings for the flat-bottom liquid ports. Allow space beyond the drawing references for fittings, connected tubing and lead routing. Select all valve and fitting materials for the liquid, concentration and temperature. Use 10 µm maximum recommended filtration and keep the operating environment within 4 to 66 °C. The manifold’s working limit remains 20 psig when used upstream of an HPLC pump.