Parker 009-0442-900 Pulse Valve 2 Way NC 0.020 in 28 VDC PTFE Exit Cone

Pressure and orifice: 1250 psi; 0.020 in (0.51 mm)
Electrical: 28 VDC; 11.2 W
Poppet and seals: PTFE; FFKM
Ports: 1/4 in A-LOK inlet; flange, exit cone
Response and function: <2 ms cycling; 2 way NC

This product is supplied to order, so pricing may vary. Contact us for up-to-date pricing and availability.

Not all items are held in stock as some are made to order or sourced on request. In-stock items usually arrive within 1–2 days, and we’ll confirm lead times by email once your order is processed.

Need help with this product or looking for an alternative? Talk to an expert today by emailing info@aegroup.uk.com or calling 01342 826488.

Description

Product Overview

Parker 009-0442-900 is a two-way normally closed Pulse valve for gas control, with a 0.020 inch (0.51 mm) orifice, 28 VDC coil and 1250 psi (86.2 bar) operating limit. It uses a PTFE poppet, FFKM seals, a 1/4 inch A-LOK inlet and a flanged outlet with an exit cone. Its inert non-isolation construction exposes the internal wetted materials to the gas.

This 28 VDC configuration combines the 0.020 inch orifice, PTFE poppet and FFKM seals with an exit cone at the flange. It suits gas pulse assemblies where the defined cone geometry is required. The operating limit remains 1250 psi, matching the no-cone PTFE option of the same orifice.

Alternative Configurations

  • Parker 009-0582-900: outlet geometry changes from Exit Cone to No Cone.
  • Parker 009-0181-900: orifice changes from 0.020 inch (0.51 mm) to 0.031 inch (0.79 mm).

Parker 009-0442-900 Technical Specifications

  • Manufacturer and family: Parker Hannifin, Pulse Valves
  • Exact part number: 009-0442-900
  • Function: Two-way normally closed, solenoid actuated
  • Maximum operating pressure: 1250 psi (86.2 bar), published operating limit
  • Vacuum capability: Down to 1 × 10⁻⁵ Torr, published family specification
  • Orifice: 0.020 inch (0.51 mm)
  • Inlet and outlet: 1/4 inch A-LOK inlet; flange, exit cone
  • Body and seals: Passivated stainless steel; PTFE poppet; FFKM (Kalrez) O-rings
  • Other wetted components: PTFE coated stainless steel armature; stainless steel main and buffer springs
  • Electrical rating: 28 VDC, 11.2 W, 400 mA nominal, 70 ohms ±5% at 21 °C
  • Electrical connection: 12 inch (304.8 mm) standard lead wires
  • Response: Less than 2 ms cycling, published family specification
  • Maximum cycle frequency: 250 Hz, published family FAQ specification
  • Helium leakage: 1 × 10⁻⁷ cc/sec/atm, published family specification
  • Operating environment: 4 to 105 °C; 100% duty cycle, potted coil
  • Proof pressure: 1.5 times rated operating pressure
  • Recommended filtration: 40 µm maximum
  • Weight: 2.8 oz (79.4 g), published family figure
  • Reference dimensions: 45.7 mm drawing reference height excluding the compression nut and ferrules; 33.8 mm flange diameter; 17.5 mm cylindrical body diameter; 4.1 mm flange thickness
  • Mounting: Four 4.75 ±0.13 mm diameter through holes, equally spaced on a 26.97 ±0.13 mm diameter bolt circle
  • Compliance: RoHS compliant, family statement

Gas Pulse and Mechanical Integration

The gas path is closed when the coil is de-energised and opens when energised. Upper inlet port 2 is over the seat and connects through the valve to lower flanged outlet port 1 under the seat. The flanged outlet includes an exit cone, which Parker identifies as improving exit stream uniformity. Check its discharge geometry against the gas sampling or spectroscopy assembly.

For optional hit and hold control, apply the full rated 28 VDC initially. The published generic two-way solenoid table gives a 6 VDC hold setting at 0.51 W. Validate the drive waveform and timing for the gas pulse application. The optional IOTA ONE driver, 060-0001-900, is designed to operate one valve at a time. Configure it for the selected coil using its manual.

Parker’s FAQ quotes a typical fastest pulse duration of 300 µs, opening response of 180 to 200 µs and closing response of 50 to 250 µs. Treat these as family timing guidance and validate the valve, driver and gas circuit together.

Four 4.75 ±0.13 mm diameter through holes, equally spaced on a 26.97 ±0.13 mm diameter bolt circle. Use 1/4 inch (6.35 mm) outside diameter tubing at the A-LOK inlet. Compression nuts and ferrules are supplied. The valve flange has an AS-568A-901 O-ring groove. Match the outlet to the mating assembly, and allow space for the fittings, tubing and electrical leads. Select the complete wetted build for the gas and actual operating conditions.

OEM Gas Control Support

Air Engineering Group Ltd can supply Parker 009-0442-900 and support its 0.020 inch orifice, 28 VDC control and exit cone outlet within OEM gas equipment. Support includes valve selection, gas circuit and manifold design, prototyping, assembly and functional testing against agreed application requirements.

Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.

Brand

Parker

Parker Hannifin develops precision fluid control valves for OEM equipment that requires compact dimensions, reliable switching and efficient electrical control. Its extensive portfolio includes miniature pneumatic solenoid valves, proportional flow valves, cartridge valves and diaphragm isolation valves for controlling gases and liquids. Available configurations support pressure and vacuum switching, proportional flow control and media isolation, with options for manifold, PCB and tube integration.
Parker valve technologies are used within respiratory equipment, anaesthesia systems, patient monitoring devices, diagnostic instruments, laboratory automation and other medical or life science equipment. AEG helps OEM customers select the appropriate valve function, pressure range, flow capacity, voltage, materials, elastomer and connection method, before integrating the selected components into custom manifolds, pneumatic assemblies or complete fluid control solutions.

Technical Information

Technical Specifications

Series and ISO
Pulse Valves

Voltage:
28 VDC

Valve Operation Type:
Electronic

Valve Actuation:
Solenoid actuated inert non-isolation poppet valve

Valve Function:
2 Way Normally Closed

Orifice Size:
0.020 inch (0.51 mm)

Primary Material:
Passivated stainless steel

Filter Grade in micron:
40 µm maximum recommended

Manufacturer:
Parker Hannifin

Max Supply Pressure:
1250 psi (86.2 bar), published operating limit

Power Supply:
11.2 W

Response:
Less than 2 ms cycling, published family specification

Temperature Range:
4 to 105 °C operating environment

Vacuum Range:
Down to 1 × 10⁻⁵ Torr, published family specification

Operating Media:
Compatible gases

ROHS Compliant:
YES
Material:
FFKM (Kalrez)
Temperature Max (Celsius):
105 °C
Temperature Minimum (Celsius) EU:
4 °C
Temperature Minimum (Fahrenheit):
105 °C

 

Air Engineering Group makes every effort to provide the most current product details directly from our manufacturers. However, because manufacturer specifications change frequently, we recommend verifying critical dimensions or performance metrics with our team prior to purchase.

 

Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.

Lead Time

Product Availability

We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.


Order In and Made to Order Items

Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.


Lead Times and Order Updates

For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.


Delivery Charges

Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.


Availability and Lead Time Enquiries

For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.

More Than Components

Experts you can trust. Technologies you can depend on.

 

Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.

 

Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.

 

The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.

 

Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.

 

Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.

 

Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.

Applications & Integrations

Applications and Integration

Parker 009-0442-900 combines a 0.020 inch orifice, 1250 psi limit, 28 VDC coil, PTFE poppet and exit cone flange. This 28 VDC configuration combines the 0.020 inch orifice, PTFE poppet and FFKM seals with an exit cone at the flange. It suits gas pulse assemblies where the defined cone geometry is required. The operating limit remains 1250 psi, matching the no-cone PTFE option of the same orifice.

Parker identifies gas pulse generation for laser spectroscopy and gas analysis as applications for the Pulse family. This is a non-isolation gas valve, so compatibility assessment includes the poppet, FFKM O-rings, stainless steel components and PTFE coated armature.

Driver and Circuit Integration

The gas path is closed when the coil is de-energised and opens when energised. Upper inlet port 2 is over the seat and connects through the valve to lower flanged outlet port 1 under the seat. The flanged outlet includes an exit cone, which Parker identifies as improving exit stream uniformity. Check its discharge geometry against the gas sampling or spectroscopy assembly.

Provide 28 VDC and capacity for the rated 11.2 W input. For optional hit and hold control, apply the full rated 28 VDC initially. The published generic two-way solenoid table gives a 6 VDC hold setting at 0.51 W. Validate the drive waveform and timing for the gas pulse application. The optional IOTA ONE driver operates one valve at a time; set it for the selected coil using its manual.

Use the four flange mounting holes on the 26.97 ±0.13 mm diameter bolt circle. Use 1/4 inch (6.35 mm) outside diameter tubing at the A-LOK inlet. Compression nuts and ferrules are supplied. The valve flange has an AS-568A-901 O-ring groove. Match the outlet to the mating assembly, and allow space for the fittings, tubing and electrical leads. Apply 40 µm maximum recommended filtration and keep the operating environment within 4 to 105 °C.

Explore Our Related Parker OEM Capabilities:

Parker Precision Miniature Valve Solutions
Learn how AEG supplies and integrates Parker miniature solenoid and proportional valves.
Follow the process from application review and concept development through to prototyping, manufacture and assembly.
OEM Pneumatic and Fluid Control Solutions
Explore our capabilities in component integration, custom manifolds and complete OEM assemblies.
Medical Device OEM Solutions
Discover our support for medical device fluid control systems, subassemblies and repeat production.

Associated Products

Components Integrated into OEM Solutions

Our capabilities extend beyond individual component supply. We integrate pneumatic and fluid control products into custom manifolds, control assemblies and complete OEM solutions developed around the specific technical, operational and production requirements of each machine, device or system.

AEG can assist from initial concept and component selection through to prototyping, assembly and testing. By combining proven products with practical design expertise, we help OEMs reduce connections, simplify installation, improve repeatability and prepare reliable solutions for ongoing production.