Parker 009-0270-900 Series 9 2 Way NC Miniature Solenoid Valve 250 psig 24 VDC 0.060 in 1/8 in A-LOK FKM

Function: 2 Way NC
Pressure: 250 psig (approx. 17.2 bar)
Orifice: 0.060 in (1.52 mm)
Electrical: 24 VDC, 12 W, flying leads
Connections and seals: 1/8 in A-LOK; FKM

This product is supplied to order, so pricing may vary. Contact us for up-to-date pricing and availability.

Not all items are held in stock as some are made to order or sourced on request. In-stock items usually arrive within 1–2 days, and we’ll confirm lead times by email once your order is processed.

Need help with this product or looking for an alternative? Talk to an expert today by emailing info@aegroup.uk.com or calling 01342 826488.

Description

Product Overview

Parker 009-0270-900 is a Series 9 miniature gas and liquid solenoid valve with 2 way normally closed operation, a 0.060 inch (1.52 mm) orifice, a 250 psig pressure limit, 24 VDC supply and 1/8 inch A-LOK connections. Its 316 stainless steel body and FKM seal build support compatible analytical media. The non-isolation construction exposes the internal wetted materials to the medium.

The 0.060 inch orifice and 250 psig rating support normally closed gas supply, analytical sample admission and process isolation. Compared with the 0.030 inch high pressure builds, this configuration has a larger flow passage and a lower operating pressure limit.

Alternative Configurations

  • Parker 009-0631-900: connection changes from 1/8 inch A-LOK to 1/8 inch FNPT; body footprint changes from 19.1 x 19.1 mm to 25.4 x 16.0 mm; mounting thread depth changes from 5.1 mm minimum to 3.18 mm minimum.
  • Parker 009-0269-900: function changes from 2 Way Normally Closed to 3 Way; pressure limit changes from 250 psig to 100 psig; published hold voltage changes from 5 VDC to 12 VDC; published hold power changes from 0.52 W to 3 W; drawing height changes from 41.7 mm to 54.9 mm including the upper port.

Parker 009-0270-900 Technical Specifications

  • Manufacturer and series: Parker Hannifin, Series 9
  • Exact part number: 009-0270-900
  • Valve function: 2 Way Normally Closed
  • Maximum operating pressure: 250 psig (approximately 17.2 bar)
  • Vacuum capability: Down to 1 × 10⁻⁵ Torr, family specification
  • Orifice diameter: 0.060 inch (1.52 mm)
  • Connections: 2 ports, 1/8 inch A-LOK
  • Body and seal build: 316 stainless steel; FKM
  • Other wetted materials: PTFE and stainless steel
  • Electrical rating: 24 VDC, 12 W, 500 mA nominal, 48 ohms ±5% at 21 °C
  • Electrical connection: 24 AWG PTFE insulated flying leads, 12 inch (304.8 mm) minimum length
  • Response time: Less than 5 ms, published orifice specification
  • Helium leak specification: 1 × 10⁻⁷ atm cc/sec, gas datasheet family performance specification
  • Operating environment: 4 to 105 °C, continuous duty coil
  • Proof pressure: 1.5 times rated pressure, family specification
  • Recommended filtration: 40 µm maximum
  • Dimensions: 41.7 mm drawing height; 19.1 mm square body; 17.5 mm coil diameter; 48.5 mm shown fitting span
  • Mounting: Two #4-40 UNC-2B mounting holes, 11.1 ±0.3 mm centre spacing and 5.1 mm minimum thread depth
  • Internal volume: 342.7 to 540.6 µL, family range
  • Compliance: RoHS compliant, family specification

Electrical Control and Installation

The flow path is closed when the coil is de-energised and opens when energised. Ports 1 and 2 identify the under-seat and over-seat connections respectively.

The 24 VDC coil has a full rated input of 12 W. After full 24 VDC actuation, hold at 5 VDC with 0.52 W published hold power; validate switching and holding performance in the assembled circuit. Use an appropriate driver and provide strain relief for the flying leads. Use 1/8 inch (approximately 3.18 mm) outside diameter tubing with the A-LOK compression fittings. The drawing shows compression nuts and ferrules as supplied. Allow clearance for fitting assembly and tube insertion.

Check the valve orientation, port assignment and upstream and downstream pressure for the complete circuit. Choose the FKM build for the medium, concentration and operating temperature. Flow depends on the pressure conditions and the properties of the gas or liquid. Use the 41.7 mm drawing height and the stated mounting pattern to plan the assembly.

OEM Fluid Control Support

Air Engineering Group Ltd can supply Parker 009-0270-900 and help integrate its 2 way nc function, 24 VDC control and 1/8 inch A-LOK interface into OEM equipment. Support includes valve selection, fluid circuit and manifold design, prototyping, assembly and functional testing against agreed application requirements.

Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.

Brand

Parker

Parker Hannifin develops precision fluid control valves for OEM equipment that requires compact dimensions, reliable switching and efficient electrical control. Its extensive portfolio includes miniature pneumatic solenoid valves, proportional flow valves, cartridge valves and diaphragm isolation valves for controlling gases and liquids. Available configurations support pressure and vacuum switching, proportional flow control and media isolation, with options for manifold, PCB and tube integration.
Parker valve technologies are used within respiratory equipment, anaesthesia systems, patient monitoring devices, diagnostic instruments, laboratory automation and other medical or life science equipment. AEG helps OEM customers select the appropriate valve function, pressure range, flow capacity, voltage, materials, elastomer and connection method, before integrating the selected components into custom manifolds, pneumatic assemblies or complete fluid control solutions.

Technical Information

Technical Specifications

Series and ISO
Series 9

Voltage:
24 VDC

Valve Operation Type:
Electronic

Valve Actuation:
Solenoid-actuated poppet valve

Valve Function:
2 Way Normally Closed

Operating Pressure:
250 psig

Orifice Size:
0.060 inch (1.52 mm)

Primary Material:
316 stainless steel

Filter Grade in micron:
40 µm maximum recommended

Manufacturer:
Parker Hannifin

Max Supply Pressure:
250 psig (approximately 17.2 bar)

Power Supply:
12 W

Response:
Less than 5 ms, published orifice specification

Temperature Range:
4 to 105 °C operating environment

Vacuum Range:
Down to 1 × 10⁻⁵ Torr, family specification

Operating Media:
Compatible gases and liquids

ROHS Compliant:
YES
Material:
FKM
Temperature Max (Celsius):
105 °C
Temperature Minimum (Celsius) EU:
4 °C
Temperature Minimum (Fahrenheit):
105 °C

 

Air Engineering Group makes every effort to provide the most current product details directly from our manufacturers. However, because manufacturer specifications change frequently, we recommend verifying critical dimensions or performance metrics with our team prior to purchase.

 

Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.

Lead Time

Product Availability

We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.


Order In and Made to Order Items

Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.


Lead Times and Order Updates

For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.


Delivery Charges

Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.


Availability and Lead Time Enquiries

For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.

More Than Components

Experts you can trust. Technologies you can depend on.

 

Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.

 

Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.

 

The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.

 

Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.

 

Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.

 

Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.

Applications & Integrations

Applications and Integration

Parker 009-0270-900 combines 2 way nc operation, a 250 psig pressure limit, 0.060 inch orifice, 24 VDC coil, 1/8 inch A-LOK connections and FKM. The 0.060 inch orifice and 250 psig rating support normally closed gas supply, analytical sample admission and process isolation. Compared with the 0.030 inch high pressure builds, this configuration has a larger flow passage and a lower operating pressure limit.

Parker lists calibrant gas control for mass spectrometers, gas chromatography and process gas analysis as Series 9 applications. The liquid range also supports process liquid analysis, high pressure liquid control and cooling circuits. Select the complete wetted-material build for the actual medium and operating conditions.

Circuit and Mechanical Integration

The flow path is closed when the coil is de-energised and opens when energised. Ports 1 and 2 identify the under-seat and over-seat connections respectively. Use 1/8 inch (approximately 3.18 mm) outside diameter tubing with the A-LOK compression fittings. The drawing shows compression nuts and ferrules as supplied. Allow clearance for fitting assembly and tube insertion. Mount the body using two #4-40 UNC-2B mounting holes, 11.1 ±0.3 mm centre spacing and 5.1 mm minimum thread depth. The valve has a 41.7 mm drawing height and a 17.5 mm coil diameter.

Provide 24 VDC and capacity for the 12 W coil input. After full 24 VDC actuation, hold at 5 VDC with 0.52 W published hold power; validate switching and holding performance in the assembled circuit. Route the 24 AWG PTFE insulated leads away from moving components and provide cable support. Use 40 µm maximum filtration and an operating environment of 4 to 105 °C.

Explore Our Related Parker OEM Capabilities:

Parker Precision Miniature Valve Solutions
Learn how AEG supplies and integrates Parker miniature solenoid and proportional valves.
Follow the process from application review and concept development through to prototyping, manufacture and assembly.
OEM Pneumatic and Fluid Control Solutions
Explore our capabilities in component integration, custom manifolds and complete OEM assemblies.
Medical Device OEM Solutions
Discover our support for medical device fluid control systems, subassemblies and repeat production.

Associated Products

Read more

Read more

Read more

Read more

Components Integrated into OEM Solutions

Our capabilities extend beyond individual component supply. We integrate pneumatic and fluid control products into custom manifolds, control assemblies and complete OEM solutions developed around the specific technical, operational and production requirements of each machine, device or system.

AEG can assist from initial concept and component selection through to prototyping, assembly and testing. By combining proven products with practical design expertise, we help OEMs reduce connections, simplify installation, improve repeatability and prepare reliable solutions for ongoing production.