Description
Product Overview
Parker 009-0100-900 is a Series 9 miniature gas and liquid solenoid valve with 2 way normally closed operation, a 0.030 inch (0.76 mm) orifice, a 1250 psig pressure limit, 12 VDC supply and 1/16 inch A-LOK connections. Its 316 stainless steel body and FKM and Vespel seal build support compatible analytical media. The non-isolation construction exposes the internal wetted materials to the medium.
The 0.030 inch orifice and 1250 psig rating suit compact high pressure gas shut-off and calibrant delivery circuits. The Vespel poppet and FKM seals must both suit the selected medium. Compatible liquid duties include controlled sampling and high pressure liquid switching.
Alternative Configurations
- Parker 009-0172-900: supply voltage changes from 12 VDC to 24 VDC; nominal current changes from 1000 mA to 500 mA; nominal coil resistance changes from 12 ohms to 48 ohms; published hold power changes from 2.1 W to 0.52 W.
- Parker 009-0272-900: supply voltage changes from 12 VDC to 24 VDC; connection changes from 1/16 inch A-LOK to 1/4-28 UNF female; nominal current changes from 1000 mA to 500 mA; nominal coil resistance changes from 12 ohms to 48 ohms; published hold power changes from 2.1 W to 0.52 W; drawing height changes from 41.7 mm to 41.9 mm; body footprint changes from 19.1 x 19.1 mm to 25.4 x 16.0 mm; mounting thread depth changes from 5.6 mm minimum to 6.4 mm.
Parker 009-0100-900 Technical Specifications
- Manufacturer and series: Parker Hannifin, Series 9
- Exact part number: 009-0100-900
- Valve function: 2 Way Normally Closed
- Maximum operating pressure: 1250 psig (approximately 86.2 bar)
- Vacuum capability: Down to 1 × 10⁻⁵ Torr, family specification
- Orifice diameter: 0.030 inch (0.76 mm)
- Connections: 2 ports, 1/16 inch A-LOK
- Body and seal build: 316 stainless steel; FKM and Vespel
- Other wetted materials: PTFE, stainless steel and Vespel poppet
- Electrical rating: 12 VDC, 12 W, 1000 mA nominal, 12 ohms ±5% at 21 °C
- Electrical connection: 24 AWG PTFE insulated flying leads, 12 inch (304.8 mm) minimum length
- Response time: Less than 5 ms, published orifice specification
- Helium leak specification: 1 × 10⁻⁷ atm cc/sec, gas datasheet family performance specification
- Operating environment: 4 to 105 °C, continuous duty coil
- Proof pressure: 1.5 times rated pressure, family specification
- Recommended filtration: 40 µm maximum
- Dimensions: 41.7 mm drawing height; 19.1 mm square body; 17.5 mm coil diameter; 41.4 mm shown fitting span
- Mounting: Two #4-40 UNC-2B mounting holes, 11.1 ±0.3 mm centre spacing and 5.6 mm minimum thread depth
- Internal volume: 342.7 to 540.6 µL, family range
- Compliance: RoHS compliant, family specification
Electrical Control and Installation
The flow path is closed when the coil is de-energised and opens when energised. Ports 1 and 2 identify the under-seat and over-seat connections respectively.
The 12 VDC coil has a full rated input of 12 W. After full 12 VDC actuation, hold at 5 VDC with 2.1 W published hold power; validate switching and holding performance in the assembled circuit. Use an appropriate driver and provide strain relief for the flying leads. Use 1/16 inch (approximately 1.6 mm) outside diameter tubing with the A-LOK compression fittings. The drawing shows compression nuts and ferrules as supplied. Allow clearance for fitting assembly and tube insertion.
Check the valve orientation, port assignment and upstream and downstream pressure for the complete circuit. Choose the FKM and Vespel build for the medium, concentration and operating temperature. Flow depends on the pressure conditions and the properties of the gas or liquid. Use the 41.7 mm drawing height and the stated mounting pattern to plan the assembly.
OEM Fluid Control Support
Air Engineering Group Ltd can supply Parker 009-0100-900 and help integrate its 2 way nc function, 12 VDC control and 1/16 inch A-LOK interface into OEM equipment. Support includes valve selection, fluid circuit and manifold design, prototyping, assembly and functional testing against agreed application requirements.
Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.
Brand
Parker
Parker Hannifin develops precision fluid control valves for OEM equipment that requires compact dimensions, reliable switching and efficient electrical control. Its extensive portfolio includes miniature pneumatic solenoid valves, proportional flow valves, cartridge valves and diaphragm isolation valves for controlling gases and liquids. Available configurations support pressure and vacuum switching, proportional flow control and media isolation, with options for manifold, PCB and tube integration.
Parker valve technologies are used within respiratory equipment, anaesthesia systems, patient monitoring devices, diagnostic instruments, laboratory automation and other medical or life science equipment. AEG helps OEM customers select the appropriate valve function, pressure range, flow capacity, voltage, materials, elastomer and connection method, before integrating the selected components into custom manifolds, pneumatic assemblies or complete fluid control solutions.
Lead Time
Product Availability
We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.
Order In and Made to Order Items
Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.
Lead Times and Order Updates
For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.
Delivery Charges
Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.
Availability and Lead Time Enquiries
For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
More Than Components
Experts you can trust. Technologies you can depend on.
Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.
Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.
The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.
Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.
Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.
Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
Applications & Integrations
Applications and Integration
Parker 009-0100-900 combines 2 way nc operation, a 1250 psig pressure limit, 0.030 inch orifice, 12 VDC coil, 1/16 inch A-LOK connections and FKM and Vespel. The 0.030 inch orifice and 1250 psig rating suit compact high pressure gas shut-off and calibrant delivery circuits. The Vespel poppet and FKM seals must both suit the selected medium. Compatible liquid duties include controlled sampling and high pressure liquid switching.
Parker lists calibrant gas control for mass spectrometers, gas chromatography and process gas analysis as Series 9 applications. The liquid range also supports process liquid analysis, high pressure liquid control and cooling circuits. Select the complete wetted-material build for the actual medium and operating conditions.
Circuit and Mechanical Integration
The flow path is closed when the coil is de-energised and opens when energised. Ports 1 and 2 identify the under-seat and over-seat connections respectively. Use 1/16 inch (approximately 1.6 mm) outside diameter tubing with the A-LOK compression fittings. The drawing shows compression nuts and ferrules as supplied. Allow clearance for fitting assembly and tube insertion. Mount the body using two #4-40 UNC-2B mounting holes, 11.1 ±0.3 mm centre spacing and 5.6 mm minimum thread depth. The valve has a 41.7 mm drawing height and a 17.5 mm coil diameter.
Provide 12 VDC and capacity for the 12 W coil input. After full 12 VDC actuation, hold at 5 VDC with 2.1 W published hold power; validate switching and holding performance in the assembled circuit. Route the 24 AWG PTFE insulated leads away from moving components and provide cable support. Use 40 µm maximum filtration and an operating environment of 4 to 105 °C.