Parker 003-0194-900 Series 3 3 Way Inert Liquid Valve 100 psig 24 VDC 1/16 in Barb FKM

Function: 3 Way
Pressure and orifice: Vacuum to 100 psig; 1.40 mm
Electrical: 24 VDC; 4.2 W; flying leads
Liquid connection: 1/16 inch (1.6 mm) ID tubing barbs
Materials: PEEK / PTFE / stainless steel / FKM

This product is supplied to order, so pricing may vary. Contact us for up-to-date pricing and availability.

Not all items are held in stock as some are made to order or sourced on request. In-stock items usually arrive within 1–2 days, and we’ll confirm lead times by email once your order is processed.

Need help with this product or looking for an alternative? Talk to an expert today by emailing info@aegroup.uk.com or calling 01342 826488.

Description

Product Overview

Parker 003-0194-900 is a Series 3 miniature inert liquid solenoid valve with 3 way operation, a 0.055 inch (1.40 mm) orifice, a vacuum to 100 psig (approximately 6.89 bar) operating range, 24 VDC coil and 1/16 inch (1.6 mm) ID tubing barbs. It combines a PEEK liquid body, PTFE and stainless steel wetted components with FKM seals.

The 1.40 mm orifice provides the highest pressure rating in the standard Series 3 ordering table. It suits circuits where a 100 psig rating takes priority over the larger orifice options.

Selection Differences

  • Voltage selection: 003-0130-900 uses 12 VDC and 2.5 W rated power with the same function, orifice, seal build and liquid interface.
  • Seal and build selection: 003-0863-900 is the dedicated bleach-compatible FKM version with the same function, pressure rating, voltage and liquid interface.
  • Circuit function: 003-0096-900 provides 2 way normally closed operation at the same pressure rating and voltage, with the same seal build and tubing size.

Parker 003-0194-900 Technical Specifications

  • Part number: 003-0194-900
  • Function and construction: 3 Way; direct acting inert non-isolation liquid valve
  • Operating pressure: Vacuum to 100 psig (approximately 6.89 bar)
  • Orifice: 0.055 inch (1.40 mm)
  • Liquid connections: 1/16 inch (1.6 mm) ID tubing barbs
  • Electrical supply: 24 VDC; 4.2 W rated power; 173 mA nominal current
  • Coil resistance: 139 ohms, ±5% at 21.1 °C
  • Electrical leads: 12 inch (304.8 mm), 26 AWG, PTFE insulated flying leads
  • Body and wetted materials: PEEK body; PTFE and stainless steel wetted components; FKM seals
  • Seal build: FKM standard version
  • Operating environment: 4 to 66 °C (40 to 150 °F)
  • Response and leakage: Less than 12 ms cycling; bubble-tight leak specification
  • Proof pressure: 1.5 times rated pressure (150 psig)
  • Filtration: 40 µm maximum recommended
  • Nominal life: 10 million cycles, application dependent
  • Internal volume: 238 µL, published family figure for the 1/16 inch barbed interface
  • Weight: 51 to 56 g, family range
  • Power reduction: 12 VDC / 1.04 W hold after 25 ms at full rated voltage
  • Compliance: RoHS compliant

Liquid and Electrical Integration

When de-energised, common port 2 connects to normally open port 3. Energising the coil switches common port 2 to normally closed port 1. This provides liquid selection or diversion between two paths.

The standard FKM build supports compatible reagent, wash solution, saline and ink circuits. Parker rates FKM favourably for deionised water, isopropanol and saline in its abbreviated compatibility chart. Select the seal against the complete liquid formulation and operating conditions. The 1/16 inch (1.6 mm) barbs are sized for tubing internal diameter, not thread size or tubing outside diameter. Use compatible tubing, secure the connections and support the valve independently of the tube runs. The body has two #4-40 UNC-2B mounting holes with 6.4 mm thread depth.

Apply full 24 VDC for the initial 25 ms, then reduce to 12 VDC for approximately 1.04 W hold power. Validate the driver and switching behaviour in the intended circuit.

The ordering code identifies the valve with its standard flying leads. Select suitable mounting hardware, compatible tubing and an electrical driver for the complete equipment assembly.

OEM Fluid Control Support

Air Engineering Group Ltd can supply Parker 003-0194-900 as an individual valve or support integration into an OEM liquid control assembly. Support can include application review, component selection, manifold and circuit design, prototyping, assembly, functional testing and repeat manufacture against agreed requirements.

Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.

Brand

Parker

Parker Hannifin develops precision fluid control valves for OEM equipment that requires compact dimensions, reliable switching and efficient electrical control. Its extensive portfolio includes miniature pneumatic solenoid valves, proportional flow valves, cartridge valves and diaphragm isolation valves for controlling gases and liquids. Available configurations support pressure and vacuum switching, proportional flow control and media isolation, with options for manifold, PCB and tube integration.
Parker valve technologies are used within respiratory equipment, anaesthesia systems, patient monitoring devices, diagnostic instruments, laboratory automation and other medical or life science equipment. AEG helps OEM customers select the appropriate valve function, pressure range, flow capacity, voltage, materials, elastomer and connection method, before integrating the selected components into custom manifolds, pneumatic assemblies or complete fluid control solutions.

Technical Information

Technical Specifications

Series and ISO
Series 3

Voltage:
24 VDC

Valve Operation Type:
Inert non-isolation liquid valve

Valve Actuation:
Direct acting solenoid

Valve Function:
3 Way

Operating Pressure:
Vacuum to 100 psig

Orifice Size:
0.055 inch (1.40 mm)

Primary Material:
PEEK

Filter Grade in micron:
40 µm maximum recommended

Manufacturer:
Parker Hannifin

Max Supply Pressure:
100 psig (approximately 6.89 bar)

Power Supply:
4.2 W

Response:
Less than 12 ms cycling

Temperature Range:
4 to 66 °C (40 to 150 °F)

Vacuum Range:
Vacuum capable; pressure and vacuum port arrangements are shown in the valve circuit drawings

Operating Media:
Compatible liquids

ROHS Compliant:
YES
Material:
FKM
Temperature Max (Celsius):
66 °C
Temperature Minimum (Celsius) EU:
4 °C
Temperature Minimum (Fahrenheit):
66 °C

 

Air Engineering Group makes every effort to provide the most current product details directly from our manufacturers. However, because manufacturer specifications change frequently, we recommend verifying critical dimensions or performance metrics with our team prior to purchase.

 

Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.

Lead Time

Product Availability

We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.


Order In and Made to Order Items

Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.


Lead Times and Order Updates

For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.


Delivery Charges

Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.


Availability and Lead Time Enquiries

For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.

More Than Components

Experts you can trust. Technologies you can depend on.

 

Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.

 

Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.

 

The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.

 

Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.

 

Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.

 

Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.

Applications & Integrations

Applications & Integration

Parker 003-0194-900 supports reagent selection, rinse switching and liquid diversion in analytical or printing equipment. Its 3 way function, 1.40 mm orifice and 100 psig limit define its place in the circuit. The 1.40 mm orifice provides the highest pressure rating in the standard Series 3 ordering table. It suits circuits where a 100 psig rating takes priority over the larger orifice options.

Liquid Compatibility

The standard FKM build supports compatible reagent, wash solution, saline and ink circuits. Parker rates FKM favourably for deionised water, isopropanol and saline in its abbreviated compatibility chart. Select the seal against the complete liquid formulation and operating conditions.

Integration Guidance

The 1/16 inch (1.6 mm) barbs are sized for tubing internal diameter, not thread size or tubing outside diameter. Use compatible tubing, secure the connections and support the valve independently of the tube runs. The body has two #4-40 UNC-2B mounting holes with 6.4 mm thread depth. When de-energised, common port 2 connects to normally open port 3. Energising the coil switches common port 2 to normally closed port 1. This provides liquid selection or diversion between two paths.

Provide a 24 VDC driver suitable for 4.2 W rated power and 173 mA nominal current. Apply full 24 VDC for the initial 25 ms, then reduce to 12 VDC for approximately 1.04 W hold power. Validate the driver and switching behaviour in the intended circuit. Size the liquid circuit for the required flow, viscosity and differential pressure, with filtration of 40 µm maximum and an operating environment of 4 to 66 °C.

Explore Our Related Parker OEM Capabilities:

Parker Precision Miniature Valve Solutions
Learn how AEG supplies and integrates Parker miniature solenoid and proportional valves.
Follow the process from application review and concept development through to prototyping, manufacture and assembly.
OEM Pneumatic and Fluid Control Solutions
Explore our capabilities in component integration, custom manifolds and complete OEM assemblies.
Medical Device OEM Solutions
Discover our support for medical device fluid control systems, subassemblies and repeat production.

Associated Products

Read more

Read more

Read more

Read more

Components Integrated into OEM Solutions

Our capabilities extend beyond individual component supply. We integrate pneumatic and fluid control products into custom manifolds, control assemblies and complete OEM solutions developed around the specific technical, operational and production requirements of each machine, device or system.

AEG can assist from initial concept and component selection through to prototyping, assembly and testing. By combining proven products with practical design expertise, we help OEMs reduce connections, simplify installation, improve repeatability and prepare reliable solutions for ongoing production.