Description
John Guest 12SCV Single Check Valve 12 mm
The John Guest 12SCV single check valve is for liquids only. Its 12 mm push-fit connections permit forward flow while resisting reverse flow. It suits compatible drinks dispense and potable-liquid lines and is unsuitable for compressed air or vacuum service.
Key product details
- Supplier: John Guest (RWC)
- Product code: 12SCV
- Type: Single check valve
- Connections: 12 mm
- Product category: Liquid Check Valves & Service Valves
Selection and use
Install 12SCV with 12 mm outside-diameter tube and orient the body arrow in the intended liquid flow direction. The range has a typical 2 kPa opening pressure; available forward pressure must also overcome the rest of the circuit resistance. The rated potable-liquid pressure is 10 bar at 20 °C or 7 bar at 65 °C. Do not allow the liquid to freeze, and include the check element in routine inspection where backflow control is important.
Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.
Lead Time
Product Availability
We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.
Order In and Made to Order Items
Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.
Lead Times and Order Updates
For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.
Delivery Charges
Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.
Availability and Lead Time Enquiries
For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
More Than Components
Experts you can trust. Technologies you can depend on.
Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.
Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.
The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.
Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.
Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.
Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
Applications & Integrations
Applications
John Guest 12SCV provides a one-way check function for a liquid line using 12 mm outside-diameter tube. It is useful in drinks dispense and compatible water circuits where reverse liquid movement must be limited at a branch or equipment connection. The actual available forward pressure must support the required liquid flow through the valve. Unlike a plain isolation valve, its job is to restrict return flow while allowing the specified forward direction. The John Guest 12SCV check valve is for liquids only; pneumatic and vacuum duties are outside its specified use. The one-way internal mechanism is distinct from a manually operated valve that merely opens or closes a line.
Integrations
In a drinks dispense or approved liquid installation, place John Guest 12SCV in the 12 mm tube run at the equipment branch it is intended to protect. Identify its inlet and outlet using the flow marking on the 12SCV valve, leaving access to the body for inspection. Use a separate service valve if the equipment also needs positive isolation for maintenance. Support the adjacent tube and confirm the pipe material and actual system conditions against John Guest technical limits. The listed valve form matters because a single check, double check and service valve perform different duties even where tube diameters match. Periodic access also allows the installer to inspect the direction marking and verify correct operation in service.