Description
ControlAir Type 625 1:1 valve-actuator volume booster
ControlAir Type 625 delivers extra air volume to a diaphragm or piston actuator while following its pneumatic pilot pressure. A soft valve seat helps avoid continuous leakage at a stable operating point; the one-to-one ratio maintains the controller’s intended pressure signal.
Key Product Details
- Supplier: ControlAir
- Manufacturer model: Type 625
- Store SKU: Type 625
- Product type: 1:1 valve-actuator volume booster
- Distinguishing details: 1:1 signal ratio; adjustable bypass and 100-mesh screen
- Product category: Pneumatic Volume Boosters
Type 625 operation
A fixed deadband and adjustable bypass allow small control corrections to pass while large deviations use the booster valve. An integral 100-mesh screen protects internal parts from larger particulate.
Type 625 configuration
The Type 625 is intended for pneumatic valve actuation with a low-flow pilot and larger actuator volume. The fixed deadband restrains unnecessary booster cycling; the bypass valve passes small controller corrections so the main valve need not open for every change. Larger commands operate the booster to speed filling or exhausting the actuator. The integrated inlet screen protects the booster, while the quality of the plant-air supply still depends on upstream preparation. Set the bypass with the actual positioner, actuator volume and pipework connected, then check both small-step stability and full-stroke time. Check air consumption at steady state separately from peak flow during a stroke. Size the branch supply for changes in actuator demand and leave space to inspect the integrated screen.
Technical specifications
Signal-to-output pressure ratio: 1:1
Signal, supply and outlet ports: 1/4 inch NPT
Maximum supply and signal pressure: 150 psig each
Integral protection: 100-mesh inlet filter
Response control: Fixed deadband and adjustable bypass
Forward and exhaust coefficient: Cv 1.5 maximum each
Exhaust capacity: 15 SCFM at 5 psig above a 20 psig outlet setting
Selection and use
For ControlAir Type 625, select the porting and pressure rating of the complete actuator system. Adjust bypass during commissioning to avoid hunting without sacrificing required valve stroke speed.
Connect the controller signal, a clean separately regulated supply and the actuator line to their correct ports. Keep service access to the integrated screen and bypass setting.
Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.
Lead Time
Product Availability
We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.
Order In and Made to Order Items
Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.
Lead Times and Order Updates
For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.
Delivery Charges
Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.
Availability and Lead Time Enquiries
For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
More Than Components
Experts you can trust. Technologies you can depend on.
Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.
Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.
The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.
Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.
Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.
Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
Applications & Integrations
Applications
ControlAir Type 625 (SKU Type 625) boosts pneumatic airflow to a larger diaphragm or piston actuator without changing the control signal’s intended output pressure. The integral adjustable bypass passes smaller signal changes and allows larger changes to open the main booster valve, balancing fast motion against stable position. This makes it useful where a low-volume pilot alone gives unacceptable actuator lag. Small command changes can pass through the bypass without opening the high-flow path, while large corrections receive additional air. The plant supply still determines the maximum achievable actuator pressure. The bypass does not increase the plant air pressure on its own.
Integrations
Run filtered plant air into the Type 625 supply, a separate pilot signal from the existing control device, and the boosted outlet to the actuator. Identify the ordered unit’s actual ports and exhaust before installation, and size lines for the required fill and vent rates. Adjust bypass incrementally while testing both increasing and decreasing signals. The positioner, air source, compatible fittings and actuator are separate from this booster. A fast initial stroke followed by overshoot suggests the bypass needs adjustment with the real valve load attached. Record the final adjustment after checking the actuator’s movement in both directions. Check that the exhaust route remains clear under the installation conditions.