Description
ControlAir P200 Pneumatic-to-Current P/I Transducer
The ControlAir P200 converts a pneumatic instrument signal into a proportional two-wire 4–20 mA current output, allowing a controller to read pressure from a pneumatic control line.
Key Product Details
- Supplier: ControlAir
- Product code: CA P200
- Manufacturer model: ControlAir P200
- Description: Pneumatic-to-Current P/I Transducer
- Product category: Pneumatic Instrumentation / PI Transducers
The P200 converts the signal from a pneumatic instrument into an electrical current that can be read by an electronic controller. Separate pneumatic and conduit connections keep the pressure input distinct from loop wiring.
The pneumatic calibration must correspond to the pressure span used by the existing instrument: a 3–15 psig control signal needs the P11 version, while a 6–30 psig signal needs P13. The current loop is powered through the two-wire connection, so a monitoring input cannot be treated as a dry contact. At 24 VDC the permitted external load reaches 700 ohms. Multiturn zero and span controls offer around ±20% calibration adjustment; record readings at both ends of the chosen pressure range during commissioning. The base P200 carries FM explosion-proof approval, while CSA explosion-proof and intrinsically safe classifications are additional options. Verify the exact device marking against the installation.
Technical specifications
Direction: 3–15 or 6–30 psig pneumatic input to a two-wire 4–20 mA output.
Input selection: P11 is the 3–15 psig range; P13 is the 6–30 psig range.
Connections: 1/4 inch NPT female air signal and 1/2 inch NPT female electrical conduit.
Loop power: 10–42 VDC at the input terminals; up to 700 ohms external load at 24 VDC.
Accuracy and response: ±0.15% of span guaranteed, ±0.10% typical; 10 ms to 99% of a step change.
Certification: FM explosion-proof base device; CSA classification depends on the option supplied.
Selection and use
Match the actual pneumatic signal range to the factory calibration and connect the current loop to a suitable 10–42 VDC supply and receiver. The zero and span adjustments allow commissioning, while loop resistance must remain within the installed supply-voltage budget. Check the installed unit’s FM marking and any separately ordered CSA approval against the location classification.
Unlike an I/P transducer, this P/I device converts pressure to current, not current to pressure. It does not regulate air or provide a pneumatic output.
Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.
Lead Time
Product Availability
We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.
Order In and Made to Order Items
Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.
Lead Times and Order Updates
For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.
Delivery Charges
Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.
Availability and Lead Time Enquiries
For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
More Than Components
Experts you can trust. Technologies you can depend on.
Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.
Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.
The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.
Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.
Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.
Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
Applications & Integrations
Applications
ControlAir P200 (SKU CA P200) converts a 3–15 or 6–30 psig pneumatic control signal into a proportional 4–20 mA electrical current. It connects an existing pneumatic instrument or field device to an electronic indicator, PLC input or control system without replacing the original air signal source. This is the pressure-to-current direction of conversion, so it is unsuitable where a current command must drive a pneumatic valve. An analogue display can therefore represent an air signal remotely, while an analogue PLC card can log changes over time. The chosen input span should follow the instrument that already produces the pneumatic signal.
Integrations
Route the sensed pressure to the pneumatic input and wire the two-wire current loop to the receiving instrument using the correct polarity and permissible loop load. Specify the selected pneumatic calibration before matching the input span to the receiving analogue channel. Keep pressure tubing tight and dry, allow enclosure access for setup, and test the current at several known pressures. Hazardous-area approval depends on the ordered P200 configuration. Specify the power and input impedance available in the receiving current loop before wiring. A differential reading at the pneumatic port and a loop-current reading at the terminals reveal whether any error originates in signal delivery or conversion.