CompAir 47703058001 is the part number for the CD250F, an air cooled refrigerant dryer rated at 25 m³/min compressed air throughput at a +3 °C pressure dew point under the manufacturer’s reference conditions. Its G3 air connection and electronic no loss drain distinguish this configuration. Cooling condenses water vapour so separated liquid can drain from the system. Its air cooled condenser needs adequate ventilation around the dryer cabinet.
CompAir 47703058001 technical information
The maximum working pressure is 14 bar, an upper limit rather than the nominal flow test pressure. The stated flow is dryer throughput, not compressor free air delivery. The historical model table gives 400 V three phase at 50 Hz, R407C refrigerant and 2.78 kW nominal absorbed power. Its catalogue envelope is 806 × 1012 × 1539 mm (width × depth × height), before pipework and access clearances. Correct capacity for actual working pressure, inlet temperature and condenser conditions.
Drain selection and neighbouring models
The CD216F is rated at 21.67 m³/min and shares this model’s G3 connection and quoted cabinet envelope. The higher rated flow of CD250F should therefore be assessed against measured demand, rather than cabinet size alone. The corresponding CD250FW uses a water cooled condenser, so plant water availability affects the choice. The electronic no loss drain responds to collected condensate instead of relying on a fixed timer, reducing routine compressed air release. Check its sensor and outlet during servicing; arrange treatment for the discharged liquid. Select its 25 m³/min capacity for a central industrial load that exceeds the capacity of small point of use dryers, checking real demand against compressor delivery.
Installation and air treatment
Allow cooling and service clearance, prevent hot exhaust recirculation and assess the highest likely plant room temperature. Install downstream of the compressor and any appropriate receiver. Specify additional separation or filtration where the required particle and oil quality calls for it. This air cooled version needs no condenser water connection, but warm rooms can reduce usable dryer capacity.
Application fit
For a production compressor room supplying several workstations or a factory compressed air ringmain, check the maximum coincident compressor delivery and whether standby machines can operate together. A +3 °C pressure dew point describes water performance under stated conditions; it does not certify oil free, breathing or product contact air. A lower required pressure dew point calls for a different drying method.
Due to the technical nature of this product, please contact our sales team on 01342 826488 or email info@aegroup.uk.com if you have any questions.
Lead Time
Product Availability
We work with a wide network of trusted manufacturers and suppliers to offer a comprehensive range of industrial components and systems. Many popular items are held in stock and available for prompt dispatch. These products are supplied directly from our UK facilities where possible to minimise lead times.
Order In and Made to Order Items
Some specialist products are not held as off the shelf stock. These items are ordered directly from the manufacturer and may be produced to order or configured for specific applications. As a result, lead times can be longer than standard stocked products, particularly for low volume or unique items. Lead times will vary depending on supplier schedules and production requirements.
Lead Times and Order Updates
For all order in products, we aim to provide clear lead time information at the point of order or shortly afterwards. Our team will keep you informed throughout the process and will advise if supplier lead times change. If you have a time critical requirement, we recommend contacting us before placing your order so we can confirm availability.
Delivery Charges
Additional delivery charges may apply to large orders, oversized items, palletised shipments, or deliveries outside the UK mainland including remote locations. Our sales team can confirm any applicable charges either before or after your order is placed to ensure full transparency.
Availability and Lead Time Enquiries
For the latest information on product availability and current lead times, please contact our team directly. We will confirm stock status, supplier lead times, and delivery expectations to support your ordering decision. You can email info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
More Than Components
Experts you can trust. Technologies you can depend on.
Air Engineering Group is more than a component supplier. We operate as an engineering partner supporting customers from concept through to long term operation. Our role extends beyond product supply into system design, integration, build, installation, and lifecycle support. This approach allows us to solve complex technical challenges while improving reliability, efficiency, and operational assurance across demanding industrial environments.
Our OEM Fluid Technology Division focuses on engineered solutions for original equipment manufacturers. We support customers with design input, component selection, manifold assemblies, sub assemblies, and fully integrated pneumatic and fluid systems. Working closely with OEM teams, we help reduce complexity, improve performance, and accelerate development while maintaining consistency from prototype through to production.
The Compressed Air and Gas Division delivers complete compressed air and gas solutions for industrial and commercial applications. This includes system design, equipment supply, installation, commissioning, servicing, and ongoing maintenance. By taking responsibility for the full system, we help customers improve uptime, control energy use, and protect critical assets throughout their operational life.
Our Pneumatic and Fluid Product Division provides a comprehensive range of valves, actuators, regulators, filtration, fittings, and control components. Supported by in house technical expertise, this division ensures customers specify the correct products for their application while benefiting from reliable supply and informed engineering support. Together, these three divisions position us as a complete engineering solutions provider rather than a simple distributor.
Our approach to business is built around a clear customer first focus supported by engineering integrity and accountability. We take time to understand each application, operating environment, and performance requirement before recommending or designing a solution. This ensures customers receive systems and components that deliver reliability, efficiency, and long term value rather than short term fixes. Through clear communication, responsive support, and consistent technical standards, we build trusted partnerships that prioritise uptime, risk reduction, and operational confidence.
Speak to our engineering team by emailing info@aegroup.uk.com or call +44 (0)1342 826488 to speak with a member of our team who can assist with your enquiry.
Applications & Integrations
Product reference: CompAir CD250F (SKU: 47703058001). This air cooled refrigerant dryer has a catalogue rating of 25 m³/min nominal throughput at a +3 °C pressure dew point. Its G3 air connection and electronic no loss drain define the selected configuration.
Suitable applications
It may suit a production compressor room supplying several workstations or a factory compressed air ringmain when measured inlet flow and the required moisture level fall within the dryer’s corrected duty. The 25 m³/min nominal rating is a starting point: calculate duty at the installation’s working pressure, compressed air inlet temperature and plant room ambient temperature. The maximum working pressure is 14 bar, an upper limit rather than the nominal flow test pressure.
Integration with the compressed air system
Allow cooling and service clearance, prevent hot exhaust recirculation and assess the highest likely plant room temperature. Fit the G3 air connection to appropriately sized pipework and account for system pressure drop, bypass arrangements and safe isolation. Confirm that the electronic drain and its outlet remain accessible, that any alarm is checked, and that condensate is handled according to the site’s disposal arrangements. Confirm the exact electrical supply before installation. Consider upstream bulk water separation and filtration where necessary, and select downstream filtration against the users’ oil and particle specifications.