Sample and Reagent Handling Valves for IVD Analysers
Match your valves and fluid paths to the analyser sequence
At Air Engineering Group (AEG), we help you select IVD analyser valves and develop the manifolds around them. We work through the sample, reagent, wash, and waste stages of your in vitro diagnostic system with your engineers, checking the valve functions, wetted materials, and flow paths each stage needs.
Whether you are developing a clinical chemistry or haematology analyser, you can start with a fluidic schematic, reagent list, or prototype test results. Our OEM Fluid Technology team can help you investigate compatibility, carryover, and how the circuit behaves as the analyser switches between fluids.
Choosing IVD analyser valves around the liquid circuit
We start by tracing each liquid from its source to the dispense or measurement point and on to waste. This shows us where paths are shared, which connections must close or switch, and what should happen when power is removed. Your flow requirements, fluid properties, and operating pressures then guide the valve selection.
| Circuit requirement | Valve arrangement to assess | What we check with your team |
|---|---|---|
| Transfer or isolate a sample | Two way shutoff or three way selection valve | Required sample volume, flow, switching sequence, leakage, and liquid retained in shared passages. |
| Select a reagent | Three way isolation valve or several valves on a manifold | Reagent chemistry, seal compatibility, port connections, pressure conditions, and switching order. |
| Introduce wash or rinse fluid | Isolation valve selected for the cleaning medium | Cleaning fluid concentration, temperature, contact time, wash volume, and which passages need flushing. |
| Route liquid to waste | Valve configuration suited to the drainage conditions | Back pressure or vacuum, fluid properties, residual liquid, and the required valve state between cycles. |
Comparing Parker LQX12 and R9 isolation valves
Parker LQX12 and R9 valves use a diaphragm to separate the liquid path from the solenoid mechanism. We assess that wetted path against your sample, reagent, and cleaning fluids, including the materials used in the manifold, tubing, and fittings.
When valve spacing is tight, we can compare the 12 mm wide LQX12 with the 9 mm wide R9. Both families include two way normally closed and three way universal configurations, with PEEK wetted components and EPDM or FFKM options. We then check the exact model’s flow capability, pressure limits, connections, and electrical requirements against your circuit.
Your reagent and cleaning fluids help determine the material choice. Share their chemical names, concentrations, temperatures, and contact times so we can assess the selected configuration under the conditions it will encounter.
Why the shared liquid path matters
Follow the full liquid sequence through the passages fluids share
We look beyond the valve when reviewing carryover. Liquid can remain in shared tubing, fittings, and manifold passages after a valve switches. We also check for unswept areas, where fluid can remain outside the main flow and take longer to clear during washing. Parker’s carryover guidance identifies fluid path design and unswept volume as factors in the amount of material carried into a subsequent sample or reagent.
For example, a 200 mm length of tubing with a 0.8 mm internal diameter holds approximately 100 µL. We include that volume alongside the valve, fittings, and manifold passages when reviewing the path between reagent selection and the measurement point.
Your engineers can then test the intended reagent, wash, and subsequent sample sequence. We use the results to assess whether changes to valve placement, shared passage length, or wash settings would help the next prototype.
IVD fluidic manifold design around the analyser sequence
Keep liquid paths compact while preserving access for testing and maintenance
During early trials, we use separate valves and tubing so we can change the circuit as your team refines the sample, reagent, and wash sequences. Once the routing is established, we look at which connections can move into a common manifold. We check that the valve ports line up with the internal passages and plan how each valve will mount, seal, and connect to the rest of the circuit.
Where several valves feed a shared outlet, we look at how much liquid could remain in that common passage between runs. A shorter passage can reduce the volume the wash cycle needs to clear. We also leave room to reach fasteners and inspect seals during servicing, and agree how to check for leakage between neighbouring channels at the expected operating pressures.
Fluidic manifold prototyping and performance testing for IVD analysers
Before building the prototype, we agree with your engineers what the fluidic assembly needs to achieve. This can include carryover limits, dispense repeatability, wash volume, leakage, and performance across the expected pressures and temperatures. We test the sequence with the intended fluids or agreed test liquids, pump or pressure source, tubing, and valve driver.
For each build, we record the valve codes, seal materials, manifold revision, fluid conditions, test sequence, and results. Your engineering and purchasing teams can then see which configuration was tested, how it performed, and what changed between prototypes as the design progresses towards repeat production.
IVD sample and reagent handling FAQs
Q1: What does AEG need to compare IVD analyser valves?
Share your fluidic schematic, sample and reagent details, cleaning fluids, flow or dispense requirements, and operating pressures. Include any temperature, space, or electrical constraints. If the specification is still developing, a circuit sketch and an outline of the analyser sequence will start the discussion.
Q2: How do Parker LQX12 and R9 valves compare?
LQX12 uses a 12 mm wide format, while R9 uses a 9 mm wide format. Both families offer two way normally closed and three way universal options. We compare the exact configuration’s wetted materials, pressure limits, flow characteristics, porting, and mounting arrangement against your analyser requirements.
Q3: Why can carryover remain after changing a valve?
Residual liquid can remain elsewhere in the shared circuit, including tubing, fittings, and manifold passages. We review the complete route and wash sequence with your team, then assess carryover at the point where the analyser dispenses or measures the fluid.
Q4: How do you assess reagent dispense repeatability?
We assess the valve together with the pump or pressure source, driver settings, liquid properties, and timing sequence. Repeated measurements at the intended dispense point help your team establish whether the assembled circuit meets its volume and repeatability targets.
Q5: Can AEG work with our existing manifold and wash sequence?
Yes. Share the manifold drawing, valve references, fluid connections, and current switching and wash sequence. If you have prototype results, we can use them to investigate retained liquid, leakage, restrictions, or inconsistent delivery and agree which changes to test next.
Review your analyser’s liquid circuit with AEG
Start with your schematic, reagent list, or latest carryover results
Send us your fluidic drawing or use the form below to explain which part of the analyser needs attention. We can work through the sample and reagent properties, required flow or dose, operating pressures, and any limits on space or power with you.
If your prototype is running, include the wash sequence and any carryover or dispense results you already have. Our OEM Fluid Technology team can review the valve and manifold together, agree the next bench checks, and help your engineering and purchasing teams plan prototype quantities or repeat assemblies.
Call 01342 826488 or email info@aegroup.uk.com.
Choosing Parker diaphragm isolation valves for your IVD analyser
AEG’s OEM Fluid Technology Division helps you select valves and design manifolds for sample and reagent handling. We check wetted material compatibility and look for passages that may be difficult to flush.
Share a circuit sketch, details of your reagents and wash fluids, target flow rates, and operating pressures. Include any wash sequences, sample carryover limits, or bench results you have.
Compare Parker R9 diaphragm isolation valves, read the Parker LQX12 isolation valve guide, or explore our Parker miniature valves and OEM fluid control solutions.
Discuss your IVD analyser prototype with AEG
AEG’s OEM Fluid Technology team helps you select Parker valves and design manifolds for sample, reagent, and wash circuits in IVD analysers.
We can assess reagent compatibility, review wash sequences, and help investigate sample carryover. We work with your engineering and purchasing teams from prototype testing through to production supply and after sales support.
Use the form below to tell us what you’re developing and where you need help. A part number, circuit sketch, or brief description of what you’re seeing on the bench is enough to get started.