EXperts you can trust. Technologies you can depend on.

Experts you can trust. Technologies you can depend on.

PSA Valve Manifolds for OEM Oxygen Concentrators

Parker Series 11/25/26 miniature solenoid valves with yellow coils and metal valve bodies

Coordinate sieve bed switching within a compact pneumatic assembly

Air Engineering Group (AEG) helps manufacturers of portable and stationary oxygen concentrators develop PSA valve manifolds around their operating sequence. We select Parker valves, review pneumatic connections, and develop assemblies that bring the compressor, sieve beds, exhaust paths, and control electronics together.

Whether you need to investigate uneven bed pressures, reduce connection complexity, or improve crossover timing, we help identify practical changes and agree how to test them. Our support covers component selection, manifold development, prototype assembly, and preparation for repeat production.

Discuss your oxygen concentrator valve assembly with AEG

Design PSA valve manifolds around your operating cycle

Map the supply, exhaust, and equalisation paths

Pressure swing adsorption (PSA) uses molecular sieve material to separate nitrogen from compressed air. In a typical arrangement, one bed produces oxygen enriched gas while the other depressurises and regenerates. The valves coordinate these changing connections as the beds alternate.

We start with your schematic and map the supply, exhaust, crossover, and any separate purge paths against the control sequence. For each valve, we identify the required flow direction, pressures at both ports, and state when electrical power is removed. This includes conditions during initial pressurisation, normal cycling, and shutdown.

Where the circuit uses pneumatic pilot control, we assess the pilot passages and main switching valves together. A restriction in either can affect when the bed connection actually changes.

Select Parker valves for the intended switching duty

Parker identifies Series MX applications in sieve bed switching and equalisation. Its example concentrator circuit shows MX valves controlling separate bed switching valves, with a Series 11 crossover valve between the beds. This illustrates why we distinguish pilot control from direct process gas switching before selecting components.

Parker valve familyPublished family detailsWhat AEG assesses
Series MXNominal 10 mm format. Versions rated for maximum operating differentials of 6 or 30 psid, approximately 0.4 or 2.0 bar.Pilot or direct switching duty, available flow, port arrangement, manifold interface, and electrical drive.
Series 11Nominal 15 mm family with brass or stainless steel bodies. Oxygen service cleaning options are available.Crossover requirements, selected orifice, pressure limits, leakage, flow direction, and cleanliness specification.


These are family references. The selected part number determines the applicable pressure, flow, electrical, and material requirements.

For an equalisation connection, we assess flow as the pressure difference between the beds falls. A flow value quoted at maximum differential does not describe the transfer rate throughout the entire crossover period.

Trace pressure losses and unwanted leakage

If one bed pressurises or exhausts more slowly than expected, we compare pressure traces with the valve commands. The investigation follows the complete path through the switching valve, fittings, manifold passages, filters, and exhaust silencer. Measurement points on either side of a suspected restriction help locate the pressure loss.

We also separate external leakage from leakage through closed valve seats or between manifold passages. During a pressure holding stage, an unintended connection to the other bed or exhaust can change the pressure profile. Isolating sections and repeating the same sequence helps establish which component or connection needs attention.

These findings guide whether to change the valve, enlarge a restricted passage, revise the exhaust arrangement, or adjust the sequence.

Explore AEG’s custom manifold solutions

Match valve timing to the electrical driver

Series MX Model 7 requires hit and hold control. Parker specifies a minimum 50 ms actuation at rated voltage, followed by reduced holding voltage. The valve must not remain continuously at full actuation voltage.

We review the driver alongside the pneumatic sequence, including simultaneous valve operation, supply variation, and enclosure temperature. Recording coil current with the command signal and bed pressure helps distinguish an electrical actuation problem from a restriction elsewhere in the circuit.

For portable equipment, the power review includes opening pulses, holding periods, and switching frequency. We assess these alongside compressor demand so your team can judge the effect on the complete instrument’s energy use.

Explore AEG’s OEM Custom Manifold Solutions

Reduce manifold size while preserving flow and access

A compact layout should shorten unnecessary connections while retaining enough passage area for the required flow. We review the routes between the compressor, switching valves, beds, and crossover connection, looking for avoidable volume, restrictive turns, and awkward fittings.

At each valve interface, we check port alignment, sealing surfaces, gasket compression, and fastening against the selected drawing. The layout also needs room for electrical connectors, pressure measurement points, and valve replacement. Bringing these details into the prototype drawing helps identify assembly difficulties before the enclosure and wiring become fixed.

Explore AEG’s custom manifold development capabilities

Define oxygen compatibility and cleanliness requirements

We identify which passages carry compressed air and which can encounter oxygen enriched gas during the operating cycle. The review covers valve internals, manifold materials, seals, fittings, and any lubricants or residues that could enter the gas path.

For respiratory equipment, oxygen compatibility includes cleanliness and resistance to ignition as well as material selection. We agree the applicable requirements with your engineering team and confirm the selected component specification with Parker.

The assembly plan also needs to preserve the agreed cleanliness through handling, testing, and packaging. Specifying a clean valve alone does not define the condition of the completed manifold.

Verify the assembly with the intended compressor and beds

Before prototyping, we agree acceptance limits for bed pressure profiles, equalisation time, internal and external leakage, electrical demand, and temperature. Testing uses the intended compressor, sieve beds, filters, silencers, and controller so the results reflect the assembled circuit.

On the bench, we record valve commands alongside pressures at agreed measurement points. Comparing the original and revised arrangements under the same conditions shows whether a change improves filling, exhaust, or crossover behaviour.

Your instrument team can then correlate those results with measured oxygen concentration and delivery flow. We also agree repeated cycling and power interruption checks, with the assembly records supporting the wider device verification programme.

Experience bringing fluidic designs into prototype production

ScubaTx had already developed the fluidic concept for its organ preservation and transport system. Its team needed support to integrate proportional valve technology and prepare the design for prototype development and manufacture.

AEG refined the existing manifold, integrated Parker VSO Low Flow valves, and worked with Parker and RVL on PCB integration. Prototype development, testing, and controlled assembly brought the components together into a working manifold solution. 

The project demonstrates our ability to connect valve selection, mechanical design, electronics, and manufacturing requirements within an OEM development programme.

Read how AEG developed the ScubaTx fluidic assembly

Oxygen concentrator manifold questions

Q1: What does a PSA valve manifold do in an oxygen concentrator?

It connects and switches the pneumatic paths used to pressurise, exhaust, and, where specified, equalise the sieve beds. Depending on the design, the manifold may carry the main process flow, operate pneumatic pilot valves, or combine both functions.

Q2: Can Series MX valves switch the full sieve bed flow?

That depends on the required flow, pressure differential, gas conditions, and valve function. A pilot operated arrangement uses the miniature valve to control a separate main switching valve. We establish which arrangement suits the circuit before selecting the valve and manifold passages.

Q3: Why might the beds fail to equalise within the required time?

Possible causes include insufficient crossover flow, restricted passages, leakage, or incorrect valve timing. Comparing both bed pressures with the crossover command helps identify the cause. Extending the opening period should follow this assessment because it also changes the overall cycle.

Q4: Does a valve listed for oxygen concentrators automatically meet the required cleanliness specification?

No. Oxygen compatibility and cleaning requirements must be confirmed for the selected configuration and operating conditions. The specification should also cover the manifold, seals, fittings, assembly handling, and packaging so the complete gas path meets the agreed requirements.

Q5: Can AEG supply an assembled oxygen concentrator valve module?

Yes. We can agree a supply scope covering the manifold, selected valves, fittings, and associated components. Drawings, a controlled parts list, and agreed assembly tests define the module supplied and the connections your production team completes.

Take your oxygen concentrator assembly from prototype to production

Prepare the valve module for repeat production

With the circuit agreed, we label the compressor feed, bed connections, exhausts, crossover path, and pressure measurement points to match the electrical sequence. Consistent references across the drawing, tubing schedule, and wiring list help teams assemble and check connections.

We record valve part numbers, drawing revisions, driver settings, sealing details, and test conditions for each prototype build. These records help your engineers compare changes and define the production configuration.

Read the Parker Series MX valve guide for pressure versions, mounting details, and drive requirements. Compare suitable crossover options within the Parker Series 11, 25, and 26 valve range, or explore our wider Parker miniature valves and OEM fluid control solutions.

Refine your oxygen concentrator valve assembly with AEG

AEG’s OEM Fluid Technology Division can help investigate uneven bed pressures, improve crossover performance, or reduce manifold size. We review Parker Series MX and suitable Series 11 options alongside your compressor, sieve beds, and control electronics to identify practical changes to the assembly.

Share a schematic showing both sieve beds, operating pressures, required flows, switching sequence, available space, and power budget. Include expected build quantities and any pressure or leakage results. Mark the valve commands and the response you need to improve so we can agree what to change and how to verify it before your next build.

Call 01342 826488 or email info@aegroup.uk.com.

Improve sieve bed switching and equalisation with AEG

AEG’s OEM Fluid Technology team can help reduce pressure losses, investigate inconsistent bed pressures, or simplify your manifold layout. We review Parker Series MX and suitable Series 11 valve options alongside your compressor, sieve beds, and control electronics to identify practical improvements to the assembly.

Share your pneumatic schematic, operating pressures, required flows, switching sequence, and power budget. If you have pressure traces or leakage results, mark the valve commands and affected flow paths so we can agree what to change and how to verify the improvement before your next build.