Pneumatic Manifolds for POCT Cartridge Actuation

Parker X-Valve miniature pneumatic valve with labelled electrical pins, solenoid assembly, valve body, and barbed tubing connections

Bring your cartridge interface and pneumatic control together

Air Engineering Group (AEG) helps manufacturers of point of care testing (POCT) instruments develop pneumatic manifolds for disposable cartridge actuation. We select Parker valves and design assemblies that connect pressure, vacuum, and vent paths to your cartridge interface, working around your pump, sensors, and control electronics.

Whether you need more independently controlled channels, faster pressure settling, or a smaller assembly, we help identify what to change and how to test it. Our support covers valve selection, manifold development, prototype testing, and assembled modules for repeat production.

Develop your POCT pneumatic assembly with AEG

Build POCT pneumatic manifolds around your cartridge’s operating sequence

Map each cartridge port to its operating sequence

In pneumatically actuated diagnostic cartridges, gas pressure or vacuum moves liquids or operates flexible membranes. The liquid stays within the disposable cartridge, while the manifold controls its pneumatic connections. We start with your port map and identify when each connection needs pressure, vacuum, isolation, or venting. This helps us choose the valve arrangement and understand which channels must operate independently.

Next, we review the pressures at each valve port throughout the sequence, including start-up, cartridge removal, and loss of power. Where a circuit uses both pressure and vacuum, the pressure difference across a valve can exceed either value considered alone. We check those conditions against the selected valve’s limits and permitted port connections.

Compare Parker valves for compact pneumatic assemblies

Parker identifies X-Valve, C7 pneumatic, and Series MX valves among its products for POCT instruments. We compare their installation requirements with the flow, leakage, and switching duty of each channel.

Parker valve familyFormat and functionsWhat AEG assesses for your assembly
X-Valve8 mm wide. Two way normally closed and selected three way universal configurations.Closely spaced channels, manifold or tube connections, and alignment with the electrical interface.
C7 pneumatic valves7 mm diameter cartridge. Two way and three way normally closed configurations.Integration into a machined cavity, including port alignment, external seals, retention, and service access.
Series MX10 mm wide. Two way and three way configurations, designed for high flow at low pressure differential.Charging or venting larger pneumatic volumes, available pressure differential, and driver compatibility.


These valves switch gas paths. Maintaining a measured pressure also depends on the pressure source, regulation, sensors, and controller. We review those components together, including electrical demand when several valves operate simultaneously. Parker specifies hit and hold control for Series MX Model 7, so the driver must provide the required opening and holding stages.

Reduce pneumatic volume without restricting the gas path

If pressure takes too long to settle at the cartridge, we trace the path from the source through the valves, tubing, filters, and manifold. Unnecessary volume takes time to pressurise or evacuate. However, narrowing a passage too far can increase restriction and slow the response.

We look for shorter connections and place valves close to the volumes they control where the layout allows. Sensor position also matters: a reading near the source may not show the pressure at the cartridge during a transition. Checking both locations under representative operating conditions helps us identify whether to revise the routing, sensing arrangement, or control response.

Explore AEG’s custom manifold solutions

Trace cartridge interface and interchannel leakage

A channel that loses pressure may have leakage through a closed valve, an external connection, or the cartridge seal. We plan separate checks for each section so your team can locate the loss before changing components. Switching a neighbouring channel while monitoring the isolated port also helps reveal unwanted pressure transfer.

At the cartridge interface, we review port alignment, sealing surfaces, compression, and the effects of repeated insertion. The design must also account for any barrier or filter protecting the instrument from liquid ingress. We include its flow resistance when assessing the pneumatic circuit.

Explore AEG’s OEM Custom Manifold Solutions

Verify pressure response with the intended cartridge and controller

Before the prototype build, we agree pressure tolerances, settling times, leakage limits, and the permitted disturbance between channels. Testing uses the intended pump, driver, sensors, and representative cartridge conditions, including sequences where several channels operate together.

On the bench, we record valve commands alongside pressure traces at agreed measurement points. Comparing the original and revised assemblies under the same conditions shows whether a shorter passage, different valve, or revised sequence improves performance. We also check cartridge insertion repeatability and the required behaviour when coil power is removed.

Your instrument team can then assess how the measured pneumatic response affects liquid movement and assay timing.

Experience turning fluidic concepts into working assemblies

ScubaTx had already developed the fluidic concept for its organ preservation and transport system. Its team needed to integrate proportional gas control into the existing manifold and turn that design into a working prototype. AEG refined the manifold for manufacture, integrated Parker VSO Low Flow valves, and worked with Parker and RVL on the PCB interface.

We assembled and tested the manifold against the project requirements, checking the integrated assembly’s performance. The completed prototype met those requirements and gave ScubaTx a tested assembly for its next development stage. Our involvement brought component integration, manufacturing considerations, and prototype verification together to help move the OEM’s existing concept forward.

Read how AEG developed the ScubaTx fluidic assembly

POCT pneumatic manifold questions

Q1: What does a pneumatic manifold do in a POCT instrument?

It routes pressure, vacuum, and vent connections to the cartridge’s pneumatic ports. The instrument uses those connections to move liquids or actuate membranes inside the cartridge. The required sequence determines the number of channels and valve functions.

Q2: Can one three way valve provide pressure, vacuum, and an isolated hold state?

A conventional two position, three way valve switches a common port between two paths. It does not provide a separate isolated hold state. A sequence requiring pressure, vacuum, and holding may need additional isolation valves or a different arrangement.

Q3: Is valve switching time the same as cartridge pressure settling time?

No. Switching time describes the valve’s response to its command. Cartridge pressure also depends on connected volume, passage restrictions, source capacity, and control behaviour. Measure settling at the point where the cartridge needs to reach its target.

Q4: Can an existing cartridge port layout be retained?

Often, provided the sealing interface, channel spacing, pressure limits, and access are suitable. AEG can review a manifold around the existing port map and identify where added channels, revised routing, or service clearances require a layout change.

Q5: Can AEG supply the assembled pneumatic module?

Yes. We can agree a supply scope covering the manifold, selected valves, and associated components. The assembly drawing, parts list, and agreed test requirements define what your production team receives and which connections it completes during installation.

Turn your POCT circuit into a repeatable pneumatic assembly

Make each pneumatic channel easier to assemble and verify

Once the circuit is agreed, we label the pressure supply, vacuum connection, vents, cartridge ports, and sensor points to match your control sequence. Matching references on the tubing schedule and wiring list help production and service teams identify each channel. We also record valve part numbers, manifold revisions, sealing details, and access needed for leak testing or replacement.

Read the Parker X-Valve guide, C7 pneumatic valve guide, and Series MX valve guide for functions, mounting details, and drive requirements. Explore other options in our Parker miniature valves and OEM fluid control solutions.

Move your cartridge actuation design towards the next build

AEG’s OEM Fluid Technology Division can help resolve interface leakage, investigate pressure settling, and fit additional pneumatic channels into your instrument. We work with your engineers to identify changes to the valve arrangement, manifold passages, or sensor connections and agree how to verify the improvement.

Share your cartridge port map, channel count, pressure and vacuum profiles, enclosure dimensions, and expected build quantities. If you have a pressure trace, mark the valve commands and show where the response differs from your target. An initial sketch is enough to start the discussion.

Call 01342 826488 or email info@aegroup.uk.com.

Refine your POCT pneumatic assembly with AEG

AEG’s OEM Fluid Technology team can help you add independent channels, reduce manifold size, or resolve inconsistent cartridge pressure. We review Parker X-Valve, C7 pneumatic, and Series MX options alongside your pump, sensors, and driver to identify practical improvements to the assembly.

Share a cartridge port map, pressure and vacuum profiles, available space, and supply voltage. If you have a pressure trace or leak test result, mark the valve commands and affected channels so we can agree what to change and how to verify the improvement before your next build.