Parker V2 Miniature Pneumatic Solenoid Valves for OEMs
Gas switching with manifold, tubing, and electrical interface options
Air Engineering Group supplies Parker V2 miniature pneumatic solenoid valves for OEM gas control assemblies. The range uses a direct acting poppet design with two way normally closed, three way normally closed, three way normally open, and distributor arrangements.
Choose the valve function and pressure model before selecting the electrical and pneumatic interfaces. The available orifice and power combinations serve different operating points, so the family’s maximum pressure of 100 psig does not apply to every model.
Manifold mounting and barbed tubing options provide different integration routes. Assess the selected configuration against gas compatibility, inlet and outlet pressures, required flow, electrical supply, and the behaviour needed when power is removed.
How the Parker V2 valve operates
Electrical energisation moves the poppet to change the gas path. A two way normally closed valve opens its controlled passage when powered. Three way valves change the connection between a common port and the other two ports, allowing supply and exhaust control or distribution between circuit paths.
Parker identifies pressure arrangements for normally closed, normally open, and distributor use, with separate vacuum diagrams. Specify the role of each port in both electrical states. Confirm the required pressure or vacuum behaviour during start-up, power loss, and switching transitions.
Parker V2 Miniature Solenoid valve OEM applications
Oxygen conservers
Parker identifies oxygen conservers as a V2 application. Assess switching against the required delivery timing, flow, inlet pressure, and electrical supply. Confirm materials and cleanliness for the intended oxygen concentration and pressure, then qualify delivery performance within the assembled device.
Portable medical equipment
Compare the selected coil rating with the device’s battery capacity and thermal budget. Include simultaneous valve operation, supply variation, and repeated switching in qualification. Measure pressure response at the controlled volume, including the effects of tubing, filters, and enclosure temperature.
Gas isolation and routing
Select normally closed, normally open, or distributor operation to match the required circuit states. Define leakage limits and the permitted behaviour during power interruption. Confirm port assignments and measure flow and pressure response with the intended connections.
Vacuum control circuits
Define vacuum level, leakage allowance, venting sequence, and recovery time. Follow Parker’s vacuum porting diagram for the selected function and protect the gas path from liquids or contamination. Test evacuation and recovery with the actual connected volume and restrictions.
Parker V2 Pneumatic Solenoid Valve Benefits
Pneumatic connection choice
Barbed connections provide a tubing interface, while manifold mounting connects the valve to passages in a common block. Compare assembly space, leakage points, tubing retention, and service access when choosing the arrangement.
Electrical interface flexibility
Wire leads, PCB pins, solder tabs, and quick connect spades provide options for different assembly methods. Select the termination alongside connector access, strain relief, PCB loading, and the intended production process.
PBT body construction
The plastic body provides an option where component weight matters. Assess the body, seals, and metal wetted parts against gas exposure, temperatures, cleaning residues, and mounting loads within the finished device.
Pressure and power selection
The model table links orifice, nominal flow coefficient, maximum supply pressure, and power. Use these linked values to select the operating point, then validate the circuit’s flow, switching, leakage, and thermal performance.
Parker V2 Technical specifications
Published specifications from Parker’s V2 technical literature.
| Parameter | Published specification |
|---|---|
| Valve design | Direct acting poppet, two or three ports |
| Functions | Two way NC; three way NC, NO, or distributor |
| Body material | PBT |
| Stem base material | C36000 brass |
| Other wetted materials | FKM, 430 FR stainless steel, and 302 stainless steel |
| Standard voltage options | 5, 12, or 24 VDC |
| Power options | 0.5, 1.0, or 2.0 W, according to model |
| Nominal orifices | 0.76 or 1.27 mm |
| Recommended filtration | 40 µm |
| Published air leakage limit | ≤0.2 sccm |
| Cycling response | Less than 30 ms |
| Tested life reference | 25 million cycles |
| Operating environment | 0°C to 70°C |
| Storage temperature | −40°C to 70°C |
| Published weight | 34.3 g |
| Published internal volume | 0.016 cm³ |
| Vacuum range | 0 to 27 inHg vacuum, 686 mmHg |
The vacuum figure is a vacuum reading, not an absolute pressure value. Confirm the required pressure relationships and porting for the application. Use the published leakage, response, and life references as qualification inputs, then validate performance with the actual gas, drive, and operating duty.
Pressure and power models
Parker publishes these linked model specifications in its pressure and flow table.
| Model | Nominal orifice | Nominal Cv | Maximum supply pressure | Power |
|---|---|---|---|---|
| 10 | 0.76 mm | 0.017 | 100 psig / 6.89 bar | 2.0 W |
| 13 | 0.76 mm | 0.017 | 50 psig / 3.45 bar | 1.0 W |
| 14 | 1.27 mm | 0.034 | 30 psig / 2.07 bar | 2.0 W |
| 16 | 0.76 mm | 0.017 | 25 psig / 1.72 bar | 0.5 W |
| 17 | 1.27 mm | 0.032 | 15 psig / 1.03 bar | 1.0 W |
| 20 | 1.27 mm | 0.030 | 6 psig / 0.41 bar | 0.5 W |
Select using the complete model and configuration. A 0.5 W coil and a 100 psig rating belong to different models. Confirm availability of the required function, voltage, termination, and body style for the selected order code.
Electrical requirements
Assess supply capacity and thermal loading against coil rating, simultaneous operation, and duty. Measure enclosure temperature during prototype testing.
| Configuration | 12 VDC power | 24 VDC power | Resistance at 20°C, 12 / 24 VDC |
|---|---|---|---|
| 0.3 mm two way | 0.5 W | 0.6 W | 288 / 995 Ω |
| 0.5 mm two way | 1.0 W | 0.85 W | 140 / 700 Ω |
| 0.8 and 1.0 mm two way, plus all three way versions | 1.0 W | 1.2 W | 140 / 495 Ω |
Published resistance tolerance is ±5%.
Materials and gas compatibility
Assess the PBT body, brass stem base, FKM seals, and stainless steel parts against the gas and anticipated contamination. Include moisture, cleaning residues, temperatures, and storage conditions when reviewing compatibility.
Parker lists air, oxygen, helium, nitrogen, carbon dioxide, carbon monoxide, and other non-reactive gases. Confirm suitability for the actual composition and exposure conditions. For oxygen service, establish the required cleanliness and material suitability for the complete assembly.
Flow selection
Parker’s typical flow curve is based on air at 24°C. Use it with the selected model’s pressure limit and account for outlet pressure when assessing the operating point. State the gas and reference conditions where requirements are expressed in standard litres per minute.
Measure performance with the intended filters, tubing, fittings, and manifold. The valve’s internal volume excludes these passages, which influence pressurisation, evacuation, and gas arrival time. Qualify switching behaviour at the device’s controlled or measurement point.
Dimensions by configuration
The basic drawing shows approximately 15.9 mm width and 17.0 mm body height. Allow additional space for the selected electrical termination, mating connections, tubing bends, and service access. Confirm the complete envelope against the current drawing.
| Configuration | Published overall length |
|---|---|
| Barbed, two way | 43.9 mm |
| Barbed, three way | 50.3 mm |
| Manifold mounted, two way | 44.5 mm |
| Manifold mounted, three way | 50.8 mm |
The above component specifications come from Parker’s V2 Miniature Solenoid Valve datasheet.
Learn more about Parker Miniature Valves and Components
Parker V2 Pneumatic and electrical integration
Tubing and manifold interfaces
The barbed option is specified for nominal 1/8 inch, approximately 3 mm, tubing. Confirm tubing dimensions, wall thickness, material, retention, and bend radius against the drawing. Avoid transmitting tubing loads into the plastic body, and leak test the assembled connections.
For manifold mounting, define port positions, sealing surfaces, fastening, and assembly access. Include the required seals and hardware in the bill of materials. Verify leakage and port isolation after assembly, allowing for the intended pressure, vacuum, and thermal conditions.
Electrical drive and reduced power control
Select the coil voltage, model power, and termination together. Size the supply and driver for the number of valves energised simultaneously. Include voltage variation, switching duty, suppression components, and enclosure temperature in prototype qualification.
Parker lists spike and hold or PWM for power reduction. Its V2 datasheet does not prescribe a numerical hit time, hold voltage, PWM frequency, or duty cycle. Obtain guidance for the selected configuration and validate opening, holding margin, and release timing with the actual driver.
Prototype qualification and production selection
the right configuration for procurement
Qualify flow, leakage, switching, pressure response, and temperature with the intended circuit. Test simultaneous operation and power loss under representative conditions, including venting or vacuum recovery where required.
Specify the Parker part number, pressure model, valve function, voltage, termination, body style, and topseat connection. Include gas composition, pressures, flow, temperatures, filtration, connected volume, and duty.
Confirm the drawing, porting, and accessories. For development, provide quantities and qualification timescales. For production, include forecasts, delivery requirements, and documentation. Assess assembly and lifecycle costs, and review substitutions or changes with engineering.
Discuss your OEM gas control application
AEG’s OEM Fluid Technology Division can guide component selection and assembly development, considering gas compatibility, pressure, flow, valve function, electrical drive, pneumatic interfaces, filtration, and maintenance requirements.
Share your schematic, gas composition, inlet and outlet pressures, flow, switching sequence, electrical supply, temperatures, connected volume, and quantities. Include the required behaviour during power loss so we can assess suitable V2 configurations and integration options.
Browse the Parker V2 pneumatic valve range, or contact Air Engineering Group on 01342 826488 or email info@aegroup.uk.com to discuss your medical, analytical, or life science liquid control application.
Find the right Parker valve for your OEM medical or life science application with guidance from Air Engineering Group. Whether you have a part number, a specification, or a fluid control challenge to solve, we can help you assess suitable options and move your project forward.
From selecting and specifying valves for prototype equipment to procurement and after sales support, AEG works with your engineering and purchasing teams to clarify requirements, address integration challenges, and match valves to your application.
Tell us about your application using the form below. Share the details you have, even if your requirements are still developing, and our team will help you identify the next step.