Parker C15 Cartridge Solenoid Valves for OEM Gas Control
Compact pneumatic switching for respiratory equipment, sampling systems, and dispense assemblies
Air Engineering Group supplies Parker C15 miniature cartridge solenoid valves for compact OEM pneumatic assemblies. The range combines a 15 mm cartridge body with two way normally closed or three way normally closed switching, providing options for gas isolation and supply or exhaust control.
Select the function, orifice, and coil together because pressure capability varies with orifice size and valve function. In addition, the 0.5 mm two way configuration has a different electrical rating from the other listed versions. Therefore, evaluate the complete configuration against the circuit requirements.
This guide covers gas control. For liquid applications, refer to the dedicated C15 liquid valve information and confirm the required materials and operating conditions.
What cartridge mounting provides
The cartridge fits into a prepared manifold cavity, with external seals separating the pneumatic passages. This arrangement can therefore reduce external tubing connections and bring switching closer to the controlled volume. However, its practical value depends on cavity accuracy, passage layout, retention, and access for servicing.
Design the manifold and valve as one assembly. Specify machining tolerances, seal contact surfaces, deburring, cleaning, and retention before releasing the block for manufacture. Then verify the assembled circuit for leakage and the required pressure response.
How the Solenoid valve functions
A two way normally closed valve isolates its controlled passage when de-energised and opens when energised. In contrast, a three way normally closed valve switches the controlled port between supply and exhaust in the pressure arrangement shown by Parker.
Parker provides separate port arrangements for pressure and vacuum use. Therefore, follow the drawing for the selected function rather than assuming identical supply and load connections. Check the behaviour during power loss, start-up, and transitions between operating states under representative operating conditions.
Parker C15 Solenoid valve OEM applications
Portable and transport ventilators
Assess gas switching against the required pressure profile, connected volume, and available electrical supply. Also include supply variation, repeated operation, and simultaneous valve switching in device qualification. Finally, confirm the behaviour during power interruption and changes in the operating sequence.
Negative pressure wound therapy
Define the required vacuum level, leakage allowance, venting sequence, and pressure recovery target. Also protect the pneumatic assembly from collected liquids and contamination. Measure circuit performance with the intended filters, tubing, and total connected volume under representative conditions instead of relying on valve response alone.
Air over liquid dispensing
Use the valve to control the gas supply or venting of a pressurised dispense circuit. Then establish dispense performance with the actual liquid, reservoir headspace, pressure regulation, and outlet restrictions. In addition, prevent liquid migration into the gas circuit and test changes in reservoir fill level.
Gas sampling and environmental monitoring
For sidestream CO₂ measurement or environmental sampling assemblies, assess leakage, residual gas, sample transit time, and moisture exposure. Also include manifold passages, filters, and tubing in the volume assessment. Then validate switching and purge sequences at the measurement point.
Parker C15 Cartridge Solenoid Valve Benefits
Compact manifold integration
Cartridge mounting provides a route to integrating valves into a common block. Evaluate the resulting assembly against the available envelope, wiring access, service clearance, and the number of controlled channels.
Published performance references
Use Parker’s response and reliability figures as qualification inputs. Validate actual switching behaviour and service life with the selected gas, pressure conditions, electrical drive, and operating duty.
Optional reduced power operation
Hit and hold control can reduce heat during extended energisation. Evaluate the holding margin and release behaviour with the proposed driver, including supply variation and the number of valves operating together.
Function and orifice choice
Two way and three way configurations provide different circuit functions. Select the orifice using its specific pressure limit and the required flow, then assess the restrictions imposed by manifold passages, filters, tubing, and fittings.
Technical specifications
Published specifications from Parker’s C Series technical literature.
| Nominal orifice | Two way maximum pressure | Three way maximum pressure |
|---|---|---|
| 0.5 mm | 10 bar / 145 psi | 10 bar / 145 psi |
| 1.0 mm | 8 bar / 116 psi | 7 bar / 102 psi |
| 1.5 mm | 4 bar / 58 psi | 3.5 bar / 50.8 psi |
| 2.0 mm | 1.5 bar / 21.8 psi | 1 bar / 14.5 psi |
These are configuration limits, not interchangeable operating points. For vacuum service, confirm the required absolute pressures and permitted pressure relationships against the selected part and Parker’s porting information. The published pressure table does not establish a separate numerical ultimate vacuum rating.
Parker C15 Valve Flow selection
Use the flow curve and configuration data for the proposed valve. State the gas and reference conditions when specifying flow, particularly where requirements are expressed in standard litres per minute. Account for both inlet and outlet pressures when evaluating the operating point.
Measure circuit performance under representative conditions after adding the intended filter, tubing, fittings, and manifold. A valve flow reference does not determine the time required to pressurise or evacuate the connected device volume.
Materials and gas compatibility
Assess stainless steel, internal seals, external seals, manifold materials, and any assembly lubricant against the gas and expected contamination. Select FKM or EPDM using compatibility information for the specific exposure conditions.
Include humidity, cleaning residues, temperature, and storage in the assessment. For oxygen service, confirm material suitability and cleanliness requirements for the actual concentration and pressure. Material names alone do not establish suitability for the assembled device.
Electrical requirements
Assess supply capacity and thermal loading against the selected coil rating, simultaneous operation, and duty. Measure enclosure temperature during prototype testing.
| Configuration | 12 VDC power | 24 VDC power | Resistance at 20°C, 12 / 24 VDC |
|---|---|---|---|
| 0.5 mm two way | 1.1 W | 1.1 W | 132 / 525 Ω |
| 0.5 mm three way | 1.7 W | 1.6 W | 85 / 361 Ω |
| 1.0, 1.5, and 2.0 mm, both functions | 1.7 W | 1.6 W | 85 / 361 Ω |
Published resistance tolerance is ±5%.
The above component specifications come from Parker’s C15 Miniature Cartridge Solenoid Valve datasheet.
Learn more about Parker Miniature Valves and Components
Parker C15 Manifold and electrical integration
Cartridge cavity and retention
Follow the current Parker cavity and mounting drawings. Parker specifies a maximum insertion force of 100 N and retention at the body indent. Arrange the retaining hardware to react pressure loads through the specified feature.
Control cavity finish, entry geometry, cleanliness, and seal handling during assembly. Confirm lubrication compatibility and provide access for cartridge removal. Include insertion checks, retention inspection, and leak testing in the assembly process.
Hit and hold control
Parker’s optional control guidance specifies at least 100 ms at rated voltage before a hold level of 50% rated voltage. For PWM holding, it gives a minimum frequency of 1 kHz and a nominal 50% duty cycle.
Reduced DC voltage and PWM duty cycle describe different drive methods. Validate the chosen method with the selected valve and circuit. Assess opening, holding margin, release timing, suppression components, and enclosure temperature with the intended number of coils energised together.
Prototype qualification and production selection
the right configuration for procurement
Define flow, leakage, switching, pressure response, and thermal criteria. Test simultaneous operation and power loss with the intended filters and connected volume.
Specify the part number, function, orifice, elastomer, voltage, interface, and drive method. Include gas composition, pressures, flow, temperatures, filtration, manifold details, and duty.
Parker lists C15-312EP05FF-000 as a 12 VDC gas valve with a 0.5 mm nominal orifice. Confirm the code, drawing, and accessories. The C15-MCS manifold is supplied separately.
Provide quantities, qualification timescales, forecasts, delivery requirements, and documentation. Assess assembly and lifecycle costs. Review substitutions and configuration changes with engineering.
Discuss your OEM gas control application
AEG’s OEM Fluid Technology Division can guide component selection and assembly development, considering gas compatibility, pressure differential, flow, electrical drive, manifold integration, filtration, and maintenance requirements.
Share your schematic, gas composition, inlet and outlet pressures, required flow, connected volume, switching sequence, electrical supply, temperatures, and quantities. Include pressure rise, venting, or vacuum targets so we can assess suitable valve configurations and integration options.
Browse the Parker C15 pneumatic valve range, or contact Air Engineering Group on 01342 826488 or email info@aegroup.uk.com to discuss your medical, analytical, or life science liquid control application.
Find the right Parker valve for your OEM medical or life science application with guidance from Air Engineering Group. Whether you have a part number, a specification, or a fluid control challenge to solve, we can help you assess suitable options and move your project forward.
From selecting and specifying valves for prototype equipment to procurement and after sales support, AEG works with your engineering and purchasing teams to clarify requirements, address integration challenges, and match valves to your application.
Tell us about your application using the form below. Share the details you have, even if your requirements are still developing, and our team will help you identify the next step.